Response Surface Methodology-Optimized FL <sub>0.1</sub> @ZIF-8 Fluorescent Probe for High-Throughput Capsaicin Analysis in Chili Products

Capsaicinoids are a group of naturally occurring organic compounds responsible for the pungency of chili. This study aimed at exploring a novel approach with multivariate-assisted Response Surface Methodology–Box Behnken Design (RSM-BBD) optimized fluorescent probe (FL0.1@ZIF-8) for the detection of capsaicin. The probe was solvothermally synthesized and characterized using XRD, FTIR, and SEM to confirm the successful incorporation of fluorescein (FL) into ZIF-8. The experimental parameters, including pH, concentration of the probe, and reaction time, were systematically optimized via RSM-BBD to enhance the sensitivity of FL0.1@ZIF-8. The results demonstrated a quenching response of FL0.1@ZIF-8 emission with capsaicin. The limit of detection (LOD) and limit of quantification (LOQ) were calculated and found to be 1.5 μM and 4.9 μM, respectively. The outcome of the study identifies efficient electronic factors as major contributors to the development of FL0.1@ZIF-8 with promising possibilities for the detection of chili hotness for food pungency evaluation, quality control, and assurance in the food industry.

Authors

Institutions

Publication Details

Journal
ACS Food Science & Technology
Published
2026-04-01
DOI
https://doi.org/10.1021/acsfoodscitech.6c00042
Primary Topic
Ion Channels and Receptors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Response Surface Methodology-Optimized FL 0.1 @ZIF-8 Fluorescent Probe for High-Throughput Capsaicin Analysis in Chili Products

Suvardhan Kanchi, Jisha Mary Thomas, Sreevidhya K. B.
ACS Food Science & Technology
Ion Channels and Receptors
article

Response Surface Methodology-Optimized FL 0.1 @ZIF-8 Fluorescent Probe for High-Throughput Capsaicin Analysis in Chili Products

Suvardhan Kanchi, Jisha Mary Thomas, Sreevidhya K. B.
article en

Abstract

Capsaicinoids are a group of naturally occurring organic compounds responsible for the pungency of chili. This study aimed at exploring a novel approach with multivariate-assisted Response Surface Methodology–Box Behnken Design (RSM-BBD) optimized fluorescent probe (FL0.1@ZIF-8) for the detection of capsaicin. The probe was solvothermally synthesized and characterized using XRD, FTIR, and SEM to confirm the successful incorporation of fluorescein (FL) into ZIF-8. The experimental parameters, including pH, concentration of the probe, and reaction time, were systematically optimized via RSM-BBD to enhance the sensitivity of FL0.1@ZIF-8. The results demonstrated a quenching response of FL0.1@ZIF-8 emission with capsaicin. The limit of detection (LOD) and limit of quantification (LOQ) were calculated and found to be 1.5 μM and 4.9 μM, respectively. The outcome of the study identifies efficient electronic factors as major contributors to the development of FL0.1@ZIF-8 with promising possibilities for the detection of chili hotness for food pungency evaluation, quality control, and assurance in the food industry.

ACS Food Science & Technology
Institute for Renewable Energy (Poland) (PL), Christ University (IN)
Openalex Percentile: Top 30%
Ion Channels and Receptors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Response Surface Methodology-Optimized FL <sub>0.1</sub> @ZIF-8 Fluorescent Probe for High-Throughput Capsaicin Analysis in Chili Products — Suvardhan Kanchi, Jisha Mary Thomas, et al. · ACS Food Science & Technology (2026) | TGRS Research Map | TGRS