Assessing variations in 3D image quality in chest CT across sites and scanners

BACKGROUND: Large CT image databases are critical to the development and validation of protocol harmonization strategies and AI models. However, image quality (IQ) can vary significantly due to differences in technology and site practices, even for scanners from the same manufacturer, which can have considerable effects on harmonization efforts and AI algorithm development. Quantifying the 3D IQ variability represented in these databases is essential to characterize protocol heterogeneity, the training data distribution, and to assess test data overlap. PURPOSE: To quantify and characterize sources of 3D IQ variability in chest CT across scanner models and imaging sites. METHODS: levels of 2.1 (low dose "LD"), 4.2 (MD), and 6.3 mGy (HD), and provide four reconstructions, including standard 'Std' and thin 'Thn' slice thicknesses for sharp "Sh" and soft "So" kernels. Variance component analysis (VCA) was performed on the resulting phantom series to quantify sources of variability in IQ partitioned into inter-scanner model, inter-site, and residual (i.e., unexplained) components. RESULTS: for So-Thn-HD (54%). CONCLUSION: This multisite phantom study demonstrates that substantial, systematic variability in 3D IQ exists across scanners, sites, metrics, dose levels, and reconstruction settings despite use of a routine non-contrast chest CT protocol. Variability was primarily driven by scanner model differences, with additional contributions from inter-site differences and residual variance for select metrics and protocols. Regardless of controlled imaging conditions that limit variability from patient anatomy, size-dependent dose effects, and tube current modulation, substantial variability in 3D IQ persists. The size-specific, relative trends observed in this study emphasize the importance of accounting for scanner model, site, and protocol-specific heterogeneity when using large CT image databases.

Authors

Institutions

Publication Details

Journal
Medical Physics
Published
2026-04-01
DOI
https://doi.org/10.1002/mp.70402
Primary Topic
Digital Radiography and Breast Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Assessing variations in 3D image quality in chest CT across sites and scanners

D Zamora, Nicholas Bevins, Kalpana M. Kanal, P. Kinahan et al.
Medical Physics
Digital Radiography and Breast Imaging
article

Assessing variations in 3D image quality in chest CT across sites and scanners

D Zamora, Nicholas Bevins, Kalpana M. Kanal, P. Kinahan, Benjamin W. Maloney, Ali Uneri, Michael F. McNitt‐Gray, Mark Supanich, J Boone, A. Fernandez Hernandez, M. Mahesh, Jeffrey H. Siewerdsen
article en

Abstract

BACKGROUND: Large CT image databases are critical to the development and validation of protocol harmonization strategies and AI models. However, image quality (IQ) can vary significantly due to differences in technology and site practices, even for scanners from the same manufacturer, which can have considerable effects on harmonization efforts and AI algorithm development. Quantifying the 3D IQ variability represented in these databases is essential to characterize protocol heterogeneity, the training data distribution, and to assess test data overlap. PURPOSE: To quantify and characterize sources of 3D IQ variability in chest CT across scanner models and imaging sites. METHODS: levels of 2.1 (low dose "LD"), 4.2 (MD), and 6.3 mGy (HD), and provide four reconstructions, including standard 'Std' and thin 'Thn' slice thicknesses for sharp "Sh" and soft "So" kernels. Variance component analysis (VCA) was performed on the resulting phantom series to quantify sources of variability in IQ partitioned into inter-scanner model, inter-site, and residual (i.e., unexplained) components. RESULTS: for So-Thn-HD (54%). CONCLUSION: This multisite phantom study demonstrates that substantial, systematic variability in 3D IQ exists across scanners, sites, metrics, dose levels, and reconstruction settings despite use of a routine non-contrast chest CT protocol. Variability was primarily driven by scanner model differences, with additional contributions from inter-site differences and residual variance for select metrics and protocols. Regardless of controlled imaging conditions that limit variability from patient anatomy, size-dependent dose effects, and tube current modulation, substantial variability in 3D IQ persists. The size-specific, relative trends observed in this study emphasize the importance of accounting for scanner model, site, and protocol-specific heterogeneity when using large CT image databases.

Medical PhysicsVol. 53(4)
Rush University Medical Center (US), The University of Texas MD Anderson Cancer Center (US), Johns Hopkins University (US), Henry Ford Health System (US), University of California, Los Angeles (US), University of Washington (US), MaineHealth (US), University of California, Davis (US)
Openalex Percentile: Top 30%
Digital Radiography and Breast Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.