A rapid, simple and high-throughput LC-HRMS workflow for contaminants analysis in distilled alcoholic beverages and associated consumers risk assessment

This study demonstrates the efficiency and relevance of a direct-injection LC-HRMS approach for the characterization of chemical contamination in distilled spirit beverages. Sixty-six spirit samples were analyzed using a UHPLC-Q/ToF workflow without extraction or pre-concentration, combining targeted analysis (TA) and suspect screening (SS). Despite its analytical simplicity, strong performances were achieved at very low concentration levels. Detection rates reached up to 61% and 84% of the investigated contaminants at 0.1 ng.mL -1 and 1 ng.mL -1 , respectively, depending on the type of spirit. Screening detection limits (SDLs) were established for 58% of the contaminants at a concentration ≤ 1 ng.mL -1 . The nature of the sample, particularly aged versus non-aged spirits, was shown to significantly influence analytical performance. TA enabled the monitoring of 960 compounds, leading to the identification of 18 chemicals, mainly pesticide residues, including substances not previously reported in spirits. A risk characterization indicated no health concern for EU adult consumers regarding these 18 compounds. SS finally expanded the chemical scope by annotating 17 additional compounds, some of them being toxic such as pyrogallol. Overall, LC-HRMS stands out as an efficient early-warning tool to improve monitoring of contaminants in beverages, and could be easily used in complement to traditional LC-MS/MS systems to investigate emerging or unprioritized chemicals. • LC-HRMS profiled contaminants in 66 spirit samples • 960 targets screened; 18 contaminants identified • Suspect screening annotated 23 additional chemicals • Direct injection enabled rapid, simple analysis • No health concern from detected pesticides in EU adults

Authors

Institutions

Publication Details

Journal
Food Control
Published
2026-04-01
DOI
https://doi.org/10.1016/j.foodcont.2026.112178
Primary Topic
Pesticide Residue Analysis and Safety
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A rapid, simple and high-throughput LC-HRMS workflow for contaminants analysis in distilled alcoholic beverages and associated consumers risk assessment

Deborah Martin, Julien Parinet, Yassine Makni, Alessandro Rozzoni et al.
Food Control
Pesticide Residue Analysis and Safety
article

A rapid, simple and high-throughput LC-HRMS workflow for contaminants analysis in distilled alcoholic beverages and associated consumers risk assessment

Deborah Martin, Julien Parinet, Yassine Makni, Alessandro Rozzoni, Jean-Charles Leblanc
article en

Abstract

This study demonstrates the efficiency and relevance of a direct-injection LC-HRMS approach for the characterization of chemical contamination in distilled spirit beverages. Sixty-six spirit samples were analyzed using a UHPLC-Q/ToF workflow without extraction or pre-concentration, combining targeted analysis (TA) and suspect screening (SS). Despite its analytical simplicity, strong performances were achieved at very low concentration levels. Detection rates reached up to 61% and 84% of the investigated contaminants at 0.1 ng.mL -1 and 1 ng.mL -1 , respectively, depending on the type of spirit. Screening detection limits (SDLs) were established for 58% of the contaminants at a concentration ≤ 1 ng.mL -1 . The nature of the sample, particularly aged versus non-aged spirits, was shown to significantly influence analytical performance. TA enabled the monitoring of 960 compounds, leading to the identification of 18 chemicals, mainly pesticide residues, including substances not previously reported in spirits. A risk characterization indicated no health concern for EU adult consumers regarding these 18 compounds. SS finally expanded the chemical scope by annotating 17 additional compounds, some of them being toxic such as pyrogallol. Overall, LC-HRMS stands out as an efficient early-warning tool to improve monitoring of contaminants in beverages, and could be easily used in complement to traditional LC-MS/MS systems to investigate emerging or unprioritized chemicals. • LC-HRMS profiled contaminants in 66 spirit samples • 960 targets screened; 18 contaminants identified • Suspect screening annotated 23 additional chemicals • Direct injection enabled rapid, simple analysis • No health concern from detected pesticides in EU adults

Food ControlVol. 187
Agence Nationale de Sécurité Sanitaire de l’Alimentation, de l’Environnement et du Travail (FR), Université Laval (CA)
HORIZON EUROPE Framework Programme
Openalex Percentile: Top 34%
Pesticide Residue Analysis and Safety
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.