Advancing dental surgical training with biomimetic lattice reinforcement in polyjet-printed models

Realistic soft-tissue behaviour is essential for surgical training, yet most additively manufactured models remain mechanically homogeneous. The purpose of this study was to investigate whether embedding biomimetic lattice architectures within standard PolyJet elastomers can improve the haptic and biomechanical realism of dental suturing models. Seven different biomimetic lattice geometries: circular, cubic, donut, C-shaped, H-shaped, L-shaped (stretcher), and H-shaped (grid) were integrated into flexible polymer matrices via PolyJet printing, six replicates per lattice. The reinforced models underwent suture pull-out, three-point bending, and durometer tests to compare elasticity, suture retention, and surface roughness with those of non-reinforced specimens. A dental surgical simulation model incorporating the cubic lattice was fabricated and evaluated using a visual analogue scale (VAS). Lattice reinforcement significantly improved mechanical performance versus plain prints across tests. The cubic lattice showed the most favourable overall profile, achieving the highest suture pull-out force (5.16 ± 0.34 N), increased bending modulus (7.31 ± 0.07 MPa vs 1.70 ± 0.09 MPa for plain), and greater hardness (Shore A 66.3–66.5 vs 28.9 ± 1.26 for plain). Surface roughness was markedly reduced in lattice-reinforced specimens (e.g., ~87–107 µm for cubic/circular/H-grid) compared with plain (~511 ± 129 µm). The dental suture simulation model produced lifelike penetration resistance and knot security. Embedding biomimetic lattices into PolyJet materials yields enhanced biomechanics and haptics without resorting to expensive polymers. The cubic lattice performed best overall and informed the final model design. This cost-effective approach can augment surgical skills while reducing reliance on cadaveric or animal models.

Authors

Institutions

Publication Details

Journal
BMC Oral Health
Published
2026-04-01
DOI
https://doi.org/10.1186/s12903-026-08242-5
Primary Topic
Surgical Simulation and Training
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Advancing dental surgical training with biomimetic lattice reinforcement in polyjet-printed models

Ewald Unger, Markus Königshofer, Francesco Moscato, Andrea Lorenz et al.
BMC Oral Health
Surgical Simulation and Training
article

Advancing dental surgical training with biomimetic lattice reinforcement in polyjet-printed models

Ewald Unger, Markus Königshofer, Francesco Moscato, Andrea Lorenz, Gunpreet Oberoi, Erik Kornfellner, Bernhard Rosenauer, Markus Ortner
article en

Abstract

Realistic soft-tissue behaviour is essential for surgical training, yet most additively manufactured models remain mechanically homogeneous. The purpose of this study was to investigate whether embedding biomimetic lattice architectures within standard PolyJet elastomers can improve the haptic and biomechanical realism of dental suturing models. Seven different biomimetic lattice geometries: circular, cubic, donut, C-shaped, H-shaped, L-shaped (stretcher), and H-shaped (grid) were integrated into flexible polymer matrices via PolyJet printing, six replicates per lattice. The reinforced models underwent suture pull-out, three-point bending, and durometer tests to compare elasticity, suture retention, and surface roughness with those of non-reinforced specimens. A dental surgical simulation model incorporating the cubic lattice was fabricated and evaluated using a visual analogue scale (VAS). Lattice reinforcement significantly improved mechanical performance versus plain prints across tests. The cubic lattice showed the most favourable overall profile, achieving the highest suture pull-out force (5.16 ± 0.34 N), increased bending modulus (7.31 ± 0.07 MPa vs 1.70 ± 0.09 MPa for plain), and greater hardness (Shore A 66.3–66.5 vs 28.9 ± 1.26 for plain). Surface roughness was markedly reduced in lattice-reinforced specimens (e.g., ~87–107 µm for cubic/circular/H-grid) compared with plain (~511 ± 129 µm). The dental suture simulation model produced lifelike penetration resistance and knot security. Embedding biomimetic lattices into PolyJet materials yields enhanced biomechanics and haptics without resorting to expensive polymers. The cubic lattice performed best overall and informed the final model design. This cost-effective approach can augment surgical skills while reducing reliance on cadaveric or animal models.

BMC Oral Health
Ludwig Boltzmann Institute for Cardiovascular Research (AT), Austrian Center for Medical Innovation and Technology (AT), Ludwig Boltzmann Institute for Age Research (AT), Austrian Cluster for Tissue Regeneration (AT), Medical University of Vienna (AT)
Bundesministerium für Bildung, Wissenschaft und Forschung
Openalex Percentile: Top 10%
Surgical Simulation and Training
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.