Fatal Necrotizing Soft Tissue Infection Following Continuous Glucose Monitoring in a Patient with Type 1 Diabetes: A Case Report and Literature Review

BACKGROUND: Continuous glucose monitoring (CGM) systems have significantly improved glycemic management in patients with type 1 diabetes mellitus and are generally considered safe. However, transcutaneous sensor insertion disrupts the skin barrier and, in susceptible individuals, may contribute to infectious complications. Severe soft tissue infections occurring in temporal association with CGM use are exceedingly rare. CASE PRESENTATION: We report a fatal case of necrotizing soft tissue infection in a 54-year-old male with long-standing type 1 diabetes mellitus occurring in temporal association with CGM use. The patient initially developed localized inflammation at a prior sensor insertion site that failed to fully resolve. Over subsequent weeks, he experienced progressive systemic symptoms and worsening local findings, culminating in advanced necrotizing infection. Despite emergency surgical debridement, broad-spectrum antimicrobial therapy, and intensive care support, the clinical course was complicated by septic shock and multiorgan failure, resulting in death. DISCUSSION: This case highlights the role of patient-specific vulnerability, persistent insertion-site inflammation, and delayed clinical recognition in the progression from localized skin changes to life-threatening infection. Importantly, this report does not establish a direct causal relationship between CGM use and necrotizing soft tissue infection but underscores the need for heightened vigilance in high-risk individuals. CONCLUSIONS: Although CGM systems have a favorable safety profile, careful inspection of insertion sites, avoidance of sensor reapplication over incompletely healed tissue, and early evaluation of persistent or progressive symptoms are essential to minimize the risk of severe outcomes in susceptible patients.

Authors

Institutions

Publication Details

Journal
Diseases
Published
2026-03-31
DOI
https://doi.org/10.3390/diseases14040124
Primary Topic
Hyperglycemia and glycemic control in critically ill and hospitalized patients
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Fatal Necrotizing Soft Tissue Infection Following Continuous Glucose Monitoring in a Patient with Type 1 Diabetes: A Case Report and Literature Review

Mădălin Guliciuc, Cristina Șerban, Cristiana Voineag, I. Grigore et al.
Diseases
Hyperglycemia and glycemic control in critically ill and hospitalized patients
article

Fatal Necrotizing Soft Tissue Infection Following Continuous Glucose Monitoring in a Patient with Type 1 Diabetes: A Case Report and Literature Review

Mădălin Guliciuc, Cristina Șerban, Cristiana Voineag, I. Grigore, Constantin Popazu, Dragoș Voicu, Alexandra Toma
article en

Abstract

BACKGROUND: Continuous glucose monitoring (CGM) systems have significantly improved glycemic management in patients with type 1 diabetes mellitus and are generally considered safe. However, transcutaneous sensor insertion disrupts the skin barrier and, in susceptible individuals, may contribute to infectious complications. Severe soft tissue infections occurring in temporal association with CGM use are exceedingly rare. CASE PRESENTATION: We report a fatal case of necrotizing soft tissue infection in a 54-year-old male with long-standing type 1 diabetes mellitus occurring in temporal association with CGM use. The patient initially developed localized inflammation at a prior sensor insertion site that failed to fully resolve. Over subsequent weeks, he experienced progressive systemic symptoms and worsening local findings, culminating in advanced necrotizing infection. Despite emergency surgical debridement, broad-spectrum antimicrobial therapy, and intensive care support, the clinical course was complicated by septic shock and multiorgan failure, resulting in death. DISCUSSION: This case highlights the role of patient-specific vulnerability, persistent insertion-site inflammation, and delayed clinical recognition in the progression from localized skin changes to life-threatening infection. Importantly, this report does not establish a direct causal relationship between CGM use and necrotizing soft tissue infection but underscores the need for heightened vigilance in high-risk individuals. CONCLUSIONS: Although CGM systems have a favorable safety profile, careful inspection of insertion sites, avoidance of sensor reapplication over incompletely healed tissue, and early evaluation of persistent or progressive symptoms are essential to minimize the risk of severe outcomes in susceptible patients.

DiseasesVol. 14(4)
Clinical Emergency Hospital Bucharest (RO), "Dunarea de Jos" University of Galati (RO), Danubius International University (RO)
Good health and well-being
Openalex Percentile: Top 36%
Hyperglycemia and glycemic control in critically ill and hospitalized patients
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.