Analytical and cross-sectional clinical validity of a smartphone-based U-Turn Test in multiple sclerosis

BACKGROUND: Gait and balance impairment can profoundly impact people with multiple sclerosis (PwMS). OBJECTIVES: To evaluate the analytical and clinical validity of the U-Turn Test (UTT), a smartphone-based assessment of dynamic balance in PwMS. METHODS: The GaitLab study (ISRCTN15993728) enrolled adult PwMS (EDSS 0.0 - 6.5). PwMS performed the UTT in a gait laboratory (supervised) using six smartphones at different wear locations and daily during a two-week remote period (unsupervised) using one smartphone (belt front). Median turn speed was computed per UTT. In the supervised setting, turn detection accuracy of smartphones was compared to motion capture (mocap) via F1 scores. Agreement between smartphone- and mocap-derived turn speed was assessed by Bland-Altman and ICC(3,1). In the unsupervised setting, test-retest reliability (ICC[2,1]) and correlations with Timed 25-Foot Walk (T25FW), EDSS, Ambulation score, 12-item Multiple Sclerosis Walking Scale (MSWS-12), and Activities-specific Balance Confidence scale (ABC) were evaluated. RESULTS: Ninety-six PwMS were included. Turn speed was comparable across supervised (1.44 rad/s) and unsupervised settings (1.47 rad/s). In the supervised setting, turn detection was highly accurate (F1 > 95% across wear locations). Turn speed agreement with mocap was high (ICC[3,1]: 0.87 - 0.92), with minimal bias (-0.04 to 0.11 rad/s). Unsupervised test-retest reliability (ICC[2,1]) was > 0.90 when aggregating ≥ 2 tests. Turn speed correlated with T25FW (rho = -0.79), EDSS (rho = -0.75), Ambulation score (rho = -0.73), MSWS-12 (rho = -0.65), and ABC (rho = -0.61). CONCLUSION: The UTT accurately and reproducibly measures turn speed across wear locations and settings, providing complementary dynamic balance insights to clinical measures and showing potential for use in multiple sclerosis trials.

Authors

Institutions

Publication Details

Journal
Multiple Sclerosis and Related Disorders
Published
2026-04-01
DOI
https://doi.org/10.1016/j.msard.2026.107171
Primary Topic
Multiple Sclerosis Research Studies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analytical and cross-sectional clinical validity of a smartphone-based U-Turn Test in multiple sclerosis

Jeremy Hobart, Licínio Craveiro, Jonathan Marsden, Richard Hosking et al.
Multiple Sclerosis and Related Disorders
Multiple Sclerosis Research Studies
article

Analytical and cross-sectional clinical validity of a smartphone-based U-Turn Test in multiple sclerosis

Jeremy Hobart, Licínio Craveiro, Jonathan Marsden, Richard Hosking, Natan Napiórkowski, Paul S. Glazier, Mike D. Rinderknecht, Lorenza Angelini, Mattia Zanon, J. Reuben Freeman, Lisa Bunn, Dimitar Stanev, Gabriela González Chan, Marta Płonka, Rafał Klimas
article en

Abstract

BACKGROUND: Gait and balance impairment can profoundly impact people with multiple sclerosis (PwMS). OBJECTIVES: To evaluate the analytical and clinical validity of the U-Turn Test (UTT), a smartphone-based assessment of dynamic balance in PwMS. METHODS: The GaitLab study (ISRCTN15993728) enrolled adult PwMS (EDSS 0.0 - 6.5). PwMS performed the UTT in a gait laboratory (supervised) using six smartphones at different wear locations and daily during a two-week remote period (unsupervised) using one smartphone (belt front). Median turn speed was computed per UTT. In the supervised setting, turn detection accuracy of smartphones was compared to motion capture (mocap) via F1 scores. Agreement between smartphone- and mocap-derived turn speed was assessed by Bland-Altman and ICC(3,1). In the unsupervised setting, test-retest reliability (ICC[2,1]) and correlations with Timed 25-Foot Walk (T25FW), EDSS, Ambulation score, 12-item Multiple Sclerosis Walking Scale (MSWS-12), and Activities-specific Balance Confidence scale (ABC) were evaluated. RESULTS: Ninety-six PwMS were included. Turn speed was comparable across supervised (1.44 rad/s) and unsupervised settings (1.47 rad/s). In the supervised setting, turn detection was highly accurate (F1 > 95% across wear locations). Turn speed agreement with mocap was high (ICC[3,1]: 0.87 - 0.92), with minimal bias (-0.04 to 0.11 rad/s). Unsupervised test-retest reliability (ICC[2,1]) was > 0.90 when aggregating ≥ 2 tests. Turn speed correlated with T25FW (rho = -0.79), EDSS (rho = -0.75), Ambulation score (rho = -0.73), MSWS-12 (rho = -0.65), and ABC (rho = -0.61). CONCLUSION: The UTT accurately and reproducibly measures turn speed across wear locations and settings, providing complementary dynamic balance insights to clinical measures and showing potential for use in multiple sclerosis trials.

Multiple Sclerosis and Related DisordersVol. 110
Roche (Switzerland) (CH), University of Plymouth (GB)
Roche
Openalex Percentile: Top 34%
Multiple Sclerosis Research Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.