Radiological stability of a quadrangular uncemented femoral component compared with its shortened version in primary total hip arthroplasty

Aims: Cementless femoral fixation is widely used in total hip arthroplasty (THA), with increasing interest in shorter femoral component designs. These femoral components aim to preserve proximal bone, promote physiological load transfer, and facilitate minimally invasive approaches. Among these, 'shortened' femoral components, derived from conventional stems and retaining a diaphyseal extension, may offer advantages in terms of implant positioning. However, clinical evidence regarding their mechanical reliability remains limited. This study aimed to compare the two-year radiological stability of a shortened uncemented quadrangular femoral component with that of its conventional-length counterpart in patients undergoing THA for osteoarthritis. Methods: We conducted a prospective, single-blind, randomized, noninferiority trial between January 2018 and December 2021. Patients undergoing primary THA were randomly assigned to receive either the conventional-length quadrangular femoral component or its shortened version. The primary outcome was femoral component migration at two years, assessed with Ein Bild Roentgen analyze - femoral component analysis (EBRA-FCA). Secondary outcomes included intraoperative and postoperative complication rates, as well as the 12-item Oxford Hip Score (OHS) at 12 months. Results: A total of 143 hips were randomized, with 139 (70 conventional-length, 69 shortened) included in the clinical analysis. Per-protocol radiological analysis was carried out on 98 hips (49 hips per group). At two years, mean femoral component migration was 0.94 mm (SD 0.49) in the shortened-femoral component group and 0.86 mm (SD 0.52) in the conventional-length group. The upper bound of the 90% CI (-0.09 to 0.25) was below the prespecified noninferiority margin of 1 mm. No significant differences were observed in complication rates or functional outcomes (p > 0.05). Conclusion: At two years, radiological outcomes of the shortened quadrangular femoral component were consistent with noninferiority compared with the conventional-length version. Although the planned sample size was not fully reached, the findings remained within the prespecified noninferiority margin.

Authors

Institutions

Publication Details

Journal
Bone & Joint Open
Published
2026-04-01
DOI
https://doi.org/10.1302/2633-1462.74.bjo-2026-0006.r1
Primary Topic
Orthopaedic implants and arthroplasty
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Radiological stability of a quadrangular uncemented femoral component compared with its shortened version in primary total hip arthroplasty

David Biau, Alix Addi, Florian Kruse, Philippe Anract
Bone & Joint Open
Orthopaedic implants and arthroplasty
article

Radiological stability of a quadrangular uncemented femoral component compared with its shortened version in primary total hip arthroplasty

David Biau, Alix Addi, Florian Kruse, Philippe Anract
article en

Abstract

Aims: Cementless femoral fixation is widely used in total hip arthroplasty (THA), with increasing interest in shorter femoral component designs. These femoral components aim to preserve proximal bone, promote physiological load transfer, and facilitate minimally invasive approaches. Among these, 'shortened' femoral components, derived from conventional stems and retaining a diaphyseal extension, may offer advantages in terms of implant positioning. However, clinical evidence regarding their mechanical reliability remains limited. This study aimed to compare the two-year radiological stability of a shortened uncemented quadrangular femoral component with that of its conventional-length counterpart in patients undergoing THA for osteoarthritis. Methods: We conducted a prospective, single-blind, randomized, noninferiority trial between January 2018 and December 2021. Patients undergoing primary THA were randomly assigned to receive either the conventional-length quadrangular femoral component or its shortened version. The primary outcome was femoral component migration at two years, assessed with Ein Bild Roentgen analyze - femoral component analysis (EBRA-FCA). Secondary outcomes included intraoperative and postoperative complication rates, as well as the 12-item Oxford Hip Score (OHS) at 12 months. Results: A total of 143 hips were randomized, with 139 (70 conventional-length, 69 shortened) included in the clinical analysis. Per-protocol radiological analysis was carried out on 98 hips (49 hips per group). At two years, mean femoral component migration was 0.94 mm (SD 0.49) in the shortened-femoral component group and 0.86 mm (SD 0.52) in the conventional-length group. The upper bound of the 90% CI (-0.09 to 0.25) was below the prespecified noninferiority margin of 1 mm. No significant differences were observed in complication rates or functional outcomes (p > 0.05). Conclusion: At two years, radiological outcomes of the shortened quadrangular femoral component were consistent with noninferiority compared with the conventional-length version. Although the planned sample size was not fully reached, the findings remained within the prespecified noninferiority margin.

Bone & Joint OpenVol. 7(4)
Université Paris Cité (FR), Hôpital Cochin (FR), Assistance Publique – Hôpitaux de Paris (FR)
Zero hunger
Openalex Percentile: Top 37%
Orthopaedic implants and arthroplasty
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.