Label matters: comparing gold nanoparticles and nanoshells with upconversion nanoparticles for quantitative lateral flow immunoassays

Lateral flow immunoassay (LFIA) is a widely used point-of-care method for both qualitative and semi- or fully quantitative detection of clinical biomarkers. There has, however, been limited data available on direct comparison of different types of labels in the LFIA for quantitative analysis using the same non-competitive assay setup. In this study, two groups of antibody-conjugated nanoparticle labels are compared: conventional gold nanostructures with densitometry readout and upconversion nanoparticles (UCNPs) suitable for sensitive luminescence readout. First, the LFIA procedure was optimized using human serum albumin (HSA) as an analyte. In the group of gold-based labels, standard gold nanoparticles were compared with gold nanoshells (AuNSs). In the case of UCNP labels, doping with Er3+ and Tm3+ and surface modifications based on poly(ethylene glycol) and poly(acrylic acid) (PAA) were compared. The best representatives—AuNSs and PAA-Tm UCNPs—were successfully used to detect human serum albumin (HSA) in spiked urine samples. To assess assay versatility, prostate-specific antigen (PSA) was detected in serum. While AuNSs tended to aggregate in serum, the PAA-Tm UCNPs maintained their stability and achieved the limit of detection of 34 pg/mL. Finally, spiked serum samples were analyzed to evaluate detection trueness, achieving a strong correlation with the reference concentrations (recoveries ranging from 82 to 118%). We showed that both label choice and sample matrix are critical: while AuNSs and PAA-Tm UCNPs performed well in urine, PAA-Tm UCNPs excelled in the more complex serum matrix. Thus, PAA-Tm UCNPs were found to be the most suitable labels for biomarker quantitation, highlighting the strong potential of UCNPs for sensitive LFIA applications.

Authors

Institutions

Publication Details

Journal
Microchimica Acta
Published
2026-03-31
DOI
https://doi.org/10.1007/s00604-026-08015-5
Primary Topic
Biosensors and Analytical Detection
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Label matters: comparing gold nanoparticles and nanoshells with upconversion nanoparticles for quantitative lateral flow immunoassays

Zdeněk Farka, Saara Kuusinen, Tero Soukka, Eliška Macháčová et al.
Microchimica Acta
Biosensors and Analytical Detection
article

Label matters: comparing gold nanoparticles and nanoshells with upconversion nanoparticles for quantitative lateral flow immunoassays

Zdeněk Farka, Saara Kuusinen, Tero Soukka, Eliška Macháčová, Jakub Máčala, Martin Kopecký
article en

Abstract

Lateral flow immunoassay (LFIA) is a widely used point-of-care method for both qualitative and semi- or fully quantitative detection of clinical biomarkers. There has, however, been limited data available on direct comparison of different types of labels in the LFIA for quantitative analysis using the same non-competitive assay setup. In this study, two groups of antibody-conjugated nanoparticle labels are compared: conventional gold nanostructures with densitometry readout and upconversion nanoparticles (UCNPs) suitable for sensitive luminescence readout. First, the LFIA procedure was optimized using human serum albumin (HSA) as an analyte. In the group of gold-based labels, standard gold nanoparticles were compared with gold nanoshells (AuNSs). In the case of UCNP labels, doping with Er3+ and Tm3+ and surface modifications based on poly(ethylene glycol) and poly(acrylic acid) (PAA) were compared. The best representatives—AuNSs and PAA-Tm UCNPs—were successfully used to detect human serum albumin (HSA) in spiked urine samples. To assess assay versatility, prostate-specific antigen (PSA) was detected in serum. While AuNSs tended to aggregate in serum, the PAA-Tm UCNPs maintained their stability and achieved the limit of detection of 34 pg/mL. Finally, spiked serum samples were analyzed to evaluate detection trueness, achieving a strong correlation with the reference concentrations (recoveries ranging from 82 to 118%). We showed that both label choice and sample matrix are critical: while AuNSs and PAA-Tm UCNPs performed well in urine, PAA-Tm UCNPs excelled in the more complex serum matrix. Thus, PAA-Tm UCNPs were found to be the most suitable labels for biomarker quantitation, highlighting the strong potential of UCNPs for sensitive LFIA applications.

Microchimica ActaVol. 193(4)
University of Turku (FI), Masaryk University (CZ)
Masarykova Univerzita, European Regional Development Fund
Openalex Percentile: Top 28%
Biosensors and Analytical Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines