Intraprocedural Rupture During Coil Embolization of a Ruptured, Rapidly Thrombosing Anterior Cerebral Artery Aneurysm: A Case Report

Acute thrombosis is often observed following the rupture of an intracranial aneurysm, and optimal coil selection during endovascular coiling is challenging. A 75-year-old woman presented with a subarachnoid hemorrhage. Computed tomography angiography revealed aneurysms at the right anterior cerebral artery A2/3 junction and the right middle cerebral artery. Based on vessel wall imaging, the anterior cerebral artery aneurysm was diagnosed as the rupture site. Initial digital subtraction angiography demonstrated a 4.4 × 3.4 × 3.4 mm aneurysm with a 1.6 mm neck. Coil embolization was performed 1 day after diagnostic angiography. Preprocedural angiography revealed significant lumen shrinkage to 2.0 mm, probably due to aneurysmal thrombosis. A 4 mm framing coil was selected based on the initial digital subtraction angiography findings. Contrast extravasation occurred after coil deployment. Immediate protamine administration, blood pressure reduction, and coil embolization with smaller coils in the opacified aneurysm dome achieved hemostasis. Final angiography confirmed complete occlusion, without residual filling or distal thrombus migration. Postoperative computed tomography showed an intracerebral hematoma in the left frontal lobe, which subsequently resolved. The patient recovered without focal neurological deficits and was transferred to a rehabilitation hospital on day 18 with mild attention deficits. This case demonstrates the risk of intraprocedural rupture when coil sizing is selected based on pre-thrombosis dimensions rather than current lumen visualization in rapidly thrombosing aneurysms. When thrombosis reduces the lumen, selecting the coil size based on pre-thrombosis dimensions may increase the risk of intraoperative rupture. Coil size selection should match the currently visualized lumen.

Authors

Institutions

Publication Details

Journal
NMC Case Report Journal
Published
2026-03-31
DOI
https://doi.org/10.2176/jns-nmc.2025-0407
Primary Topic
Intracranial Aneurysms: Treatment and Complications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Intraprocedural Rupture During Coil Embolization of a Ruptured, Rapidly Thrombosing Anterior Cerebral Artery Aneurysm: A Case Report

Taro Suzuki, Yasushi OGASAWARA, Yosuke AKAMATSU
NMC Case Report Journal
Intracranial Aneurysms: Treatment and Complications
article

Intraprocedural Rupture During Coil Embolization of a Ruptured, Rapidly Thrombosing Anterior Cerebral Artery Aneurysm: A Case Report

Taro Suzuki, Yasushi OGASAWARA, Yosuke AKAMATSU
article en

Abstract

Acute thrombosis is often observed following the rupture of an intracranial aneurysm, and optimal coil selection during endovascular coiling is challenging. A 75-year-old woman presented with a subarachnoid hemorrhage. Computed tomography angiography revealed aneurysms at the right anterior cerebral artery A2/3 junction and the right middle cerebral artery. Based on vessel wall imaging, the anterior cerebral artery aneurysm was diagnosed as the rupture site. Initial digital subtraction angiography demonstrated a 4.4 × 3.4 × 3.4 mm aneurysm with a 1.6 mm neck. Coil embolization was performed 1 day after diagnostic angiography. Preprocedural angiography revealed significant lumen shrinkage to 2.0 mm, probably due to aneurysmal thrombosis. A 4 mm framing coil was selected based on the initial digital subtraction angiography findings. Contrast extravasation occurred after coil deployment. Immediate protamine administration, blood pressure reduction, and coil embolization with smaller coils in the opacified aneurysm dome achieved hemostasis. Final angiography confirmed complete occlusion, without residual filling or distal thrombus migration. Postoperative computed tomography showed an intracerebral hematoma in the left frontal lobe, which subsequently resolved. The patient recovered without focal neurological deficits and was transferred to a rehabilitation hospital on day 18 with mild attention deficits. This case demonstrates the risk of intraprocedural rupture when coil sizing is selected based on pre-thrombosis dimensions rather than current lumen visualization in rapidly thrombosing aneurysms. When thrombosis reduces the lumen, selecting the coil size based on pre-thrombosis dimensions may increase the risk of intraoperative rupture. Coil size selection should match the currently visualized lumen.

NMC Case Report JournalVol. 13(0)
Iwate Medical University (JP), Iwate Prefectural Central Hospital (JP)
Good health and well-being
Openalex Percentile: Top 24%
Intracranial Aneurysms: Treatment and Complications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Intraprocedural Rupture During Coil Embolization of a Ruptured, Rapidly Thrombosing Anterior Cerebral Artery Aneurysm: A Case Report — Taro Suzuki, Yasushi OGASAWARA, et al. · NMC Case Report Journal (2026) | TGRS Research Map | TGRS