Quantifying Multiplanar Alignment Errors From Patient‐Specific Guide Malpositioning in Medial Opening Wedge High Tibial Osteotomy

Patient-specific cutting guides are widely used in medial opening wedge high tibial osteotomy to improve alignment accuracy, yet their multiplanar sensitivity to intraoperative malpositioning remains poorly quantified. This study investigated how translational and rotational malpositioning of patient-specific cutting guides affect postoperative multiplanar alignment using virtual surgical simulation. Virtual osteotomy procedures were performed on twenty tibial models reconstructed from preoperative computed tomography scans, targeting a 62.5% weight-bearing line. Guides were systematically malpositioned vertically, rotationally, and horizontally along the anteromedial tibial cortex. Postoperative medial proximal tibial angle, posterior proximal tibial angle, and tibial torsion were compared with the ideal plan, and clinically acceptable alignment error was defined as within 1°. Vertical malpositioning predominantly affected coronal alignment, with distal displacement greater than 8 mm producing medial proximal tibial angle overcorrection beyond acceptable limits, while posterior proximal tibial angle and tibial torsion were relatively insensitive within 10 mm. Rotational malpositioning affected all alignment parameters, with tibial torsion being the most sensitive, and acceptable alignment was maintained only between -10° and +8°. Horizontal malpositioning produced variable effects, particularly on posterior proximal tibial angle, with acceptable alignment maintained between -4 mm and +3 mm, while tibial torsion was minimally affected. Clinical Significance: This study defines clinically acceptable ranges of patient-specific cutting guide malpositioning in medial opening wedge high tibial osteotomy and identifies which displacement modes most strongly affect coronal, sagittal, and axial alignment. These findings provide practical thresholds to guide PSI design, fixation, and intraoperative placement, helping to reduce alignment errors arising from subtle guide mispositioning.

Authors

Institutions

Publication Details

Journal
Journal of Orthopaedic Research®
Published
2026-04-01
DOI
https://doi.org/10.1002/jor.70199
Primary Topic
Total Knee Arthroplasty Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Quantifying Multiplanar Alignment Errors From Patient‐Specific Guide Malpositioning in Medial Opening Wedge High Tibial Osteotomy

Takaaki Hiranaka, Christopher J. Davey, David Parker
Journal of Orthopaedic Research®
Total Knee Arthroplasty Outcomes
article

Quantifying Multiplanar Alignment Errors From Patient‐Specific Guide Malpositioning in Medial Opening Wedge High Tibial Osteotomy

Takaaki Hiranaka, Christopher J. Davey, David Parker
article en

Abstract

Patient-specific cutting guides are widely used in medial opening wedge high tibial osteotomy to improve alignment accuracy, yet their multiplanar sensitivity to intraoperative malpositioning remains poorly quantified. This study investigated how translational and rotational malpositioning of patient-specific cutting guides affect postoperative multiplanar alignment using virtual surgical simulation. Virtual osteotomy procedures were performed on twenty tibial models reconstructed from preoperative computed tomography scans, targeting a 62.5% weight-bearing line. Guides were systematically malpositioned vertically, rotationally, and horizontally along the anteromedial tibial cortex. Postoperative medial proximal tibial angle, posterior proximal tibial angle, and tibial torsion were compared with the ideal plan, and clinically acceptable alignment error was defined as within 1°. Vertical malpositioning predominantly affected coronal alignment, with distal displacement greater than 8 mm producing medial proximal tibial angle overcorrection beyond acceptable limits, while posterior proximal tibial angle and tibial torsion were relatively insensitive within 10 mm. Rotational malpositioning affected all alignment parameters, with tibial torsion being the most sensitive, and acceptable alignment was maintained only between -10° and +8°. Horizontal malpositioning produced variable effects, particularly on posterior proximal tibial angle, with acceptable alignment maintained between -4 mm and +3 mm, while tibial torsion was minimally affected. Clinical Significance: This study defines clinically acceptable ranges of patient-specific cutting guide malpositioning in medial opening wedge high tibial osteotomy and identifies which displacement modes most strongly affect coronal, sagittal, and axial alignment. These findings provide practical thresholds to guide PSI design, fixation, and intraoperative placement, helping to reduce alignment errors arising from subtle guide mispositioning.

Journal of Orthopaedic Research®Vol. 44(4)
Okayama University (JP), Sydney Orthopaedic Research Institute (AU)
Openalex Percentile: Top 25%
Total Knee Arthroplasty Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.