Impact of design optimization on cyclic loading performance of novel pedicle screw and comparison with control device: a bilayer model simulation study

This study investigates the fatigue behaviour of a novel pedicle screw design, comparing its performance with a control device using the finite element (FE) method. Pedicle screw-based treatments are standard methods in spinal fusion procedures. However, complications such as screw loosening and breakage occur in both osteoporotic and non-osteoporotic patients, often due to high bone-implant interface stress and fatigue failure. A novel pedicle screw was designed, and its performance was compared with a control device. A cylindrical bone model of human vertebrae was developed with lamina and cortico-cancellous properties, and the screws were assigned properties of medical grade titanium alloy. The outer surfaces of the screw head model were constrained, and a time varying moment simulating clinical conditions was applied at a distance from the screw head. Stress and strain on the bone model, safety factor, life, and fatigue sensitivity on the screws were determined. Results indicate that the von Mises stress on the bone models was reduced for the novel design, and it performed better in terms of life than the control device. The novel design also provided a greater safety factor than the control device, which is likely to improve pedicle screw life. These findings suggest that the novel screw design enhances performance, potentially leading to better patient outcomes. The study offers valuable insights for researchers developing spinal pedicle screws and evaluating their cyclic performance using FE analysis.

Authors

Institutions

Publication Details

Journal
Medical Engineering & Physics
Published
2026-03-31
DOI
https://doi.org/10.1088/1873-4030/ae5963
Primary Topic
Spinal Fractures and Fixation Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Impact of design optimization on cyclic loading performance of novel pedicle screw and comparison with control device: a bilayer model simulation study

Roy Joseph, Gurunathan Saravana Kumar, Arvind Kumar Prajapati, P. R. Umashankar et al.
Medical Engineering & Physics
Spinal Fractures and Fixation Techniques
article

Impact of design optimization on cyclic loading performance of novel pedicle screw and comparison with control device: a bilayer model simulation study

Roy Joseph, Gurunathan Saravana Kumar, Arvind Kumar Prajapati, P. R. Umashankar, Harikrishna Varma
article en

Abstract

This study investigates the fatigue behaviour of a novel pedicle screw design, comparing its performance with a control device using the finite element (FE) method. Pedicle screw-based treatments are standard methods in spinal fusion procedures. However, complications such as screw loosening and breakage occur in both osteoporotic and non-osteoporotic patients, often due to high bone-implant interface stress and fatigue failure. A novel pedicle screw was designed, and its performance was compared with a control device. A cylindrical bone model of human vertebrae was developed with lamina and cortico-cancellous properties, and the screws were assigned properties of medical grade titanium alloy. The outer surfaces of the screw head model were constrained, and a time varying moment simulating clinical conditions was applied at a distance from the screw head. Stress and strain on the bone model, safety factor, life, and fatigue sensitivity on the screws were determined. Results indicate that the von Mises stress on the bone models was reduced for the novel design, and it performed better in terms of life than the control device. The novel design also provided a greater safety factor than the control device, which is likely to improve pedicle screw life. These findings suggest that the novel screw design enhances performance, potentially leading to better patient outcomes. The study offers valuable insights for researchers developing spinal pedicle screws and evaluating their cyclic performance using FE analysis.

Medical Engineering & PhysicsVol. 147(4)
Indian Institute of Technology Madras (IN), Sree Chitra Thirunal Institute for Medical Sciences and Technology (IN)
Openalex Percentile: Top 30%
Spinal Fractures and Fixation Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.