3D-Printed Closed-Channel Spiral Inertial Microfluidic Device for Size-Based Particle Separation

Spiral inertial microfluidic devices provide a simple, high-throughput approach for size-based particle separation; however, translating PDMS-optimized designs into monolithic, fully enclosed 3D-printed channels is often limited by printability and post-print channel clearing. In our previous PDMS study, a 400×120µm spiral achieved high separation performance after computational optimization and experimental validation. To translate this high-performing PDMS concept into a faster and more cost-effective manufacturing approach, the same separation principle is transferred to a fully 3D-printed, closed-channel spiral device, and the geometry is re-optimized around manufacturability constraints. Printing trials showed that enclosed channels at 400×120µm and 600×180µm could not be cleared reliably due to trapped resin and frequent blockage, most often near the inner-outlet region. In contrast, 800×240µm and 1200×360µm channels were printed and flushed successfully, and 800×240µm was selected as the smallest reproducibly functional cross-section. Particle-tracking simulations were then used to re-optimize spiral development length, showing that a 4-turn device provides limited collection for 12µm targets (10%), intermediate lengths (5-7 turns) improve collection to 50%, and an 8-turn spiral achieves complete large-particle collection (100%) across tested target sizes (12-24µm) while reducing small-particle crossover. Experimental validation of the 8-turn 800×240µm device at Q=6mL min-1 using fluorescent polystyrene particles (18µm target; 6µm background) yielded an average collection efficiency of 84% and an inner-outlet purity of 92%. Overall, these results demonstrate that spiral inertial separation can be retained in a monolithic 3D-printed format when the design is re-optimized around the smallest reliably clearable enclosed cross-section and sufficient spiral development length.

Authors

Institutions

Publication Details

Journal
Micromachines
Published
2026-03-31
DOI
https://doi.org/10.3390/mi17040435
Primary Topic
Microfluidic and Bio-sensing Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

3D-Printed Closed-Channel Spiral Inertial Microfluidic Device for Size-Based Particle Separation

Gamze Gediz İliş, Eda Özyilmaz
Micromachines
Microfluidic and Bio-sensing Technologies
article

3D-Printed Closed-Channel Spiral Inertial Microfluidic Device for Size-Based Particle Separation

Gamze Gediz İliş, Eda Özyilmaz
article en

Abstract

Spiral inertial microfluidic devices provide a simple, high-throughput approach for size-based particle separation; however, translating PDMS-optimized designs into monolithic, fully enclosed 3D-printed channels is often limited by printability and post-print channel clearing. In our previous PDMS study, a 400×120µm spiral achieved high separation performance after computational optimization and experimental validation. To translate this high-performing PDMS concept into a faster and more cost-effective manufacturing approach, the same separation principle is transferred to a fully 3D-printed, closed-channel spiral device, and the geometry is re-optimized around manufacturability constraints. Printing trials showed that enclosed channels at 400×120µm and 600×180µm could not be cleared reliably due to trapped resin and frequent blockage, most often near the inner-outlet region. In contrast, 800×240µm and 1200×360µm channels were printed and flushed successfully, and 800×240µm was selected as the smallest reproducibly functional cross-section. Particle-tracking simulations were then used to re-optimize spiral development length, showing that a 4-turn device provides limited collection for 12µm targets (10%), intermediate lengths (5-7 turns) improve collection to 50%, and an 8-turn spiral achieves complete large-particle collection (100%) across tested target sizes (12-24µm) while reducing small-particle crossover. Experimental validation of the 8-turn 800×240µm device at Q=6mL min-1 using fluorescent polystyrene particles (18µm target; 6µm background) yielded an average collection efficiency of 84% and an inner-outlet purity of 92%. Overall, these results demonstrate that spiral inertial separation can be retained in a monolithic 3D-printed format when the design is re-optimized around the smallest reliably clearable enclosed cross-section and sufficient spiral development length.

MicromachinesVol. 17(4)
Gebze Technical University (TR), Northeastern University (US)
Openalex Percentile: Top 36%
Microfluidic and Bio-sensing Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.