Demonstrating the reliability of randomized measurement and verification for switchable control retrofits using a large open-source dataset

Conventional measurement and verification (M&V) methods for estimating energy savings rely on comparing pre- and post-retrofit performance. They are often time-consuming and unreliable, especially when non-routine events, such as step changes or more gradual changes in building operation, occur during the M&V process. When those events are unrelated to the retrofit intervention and significantly affect building energy consumption, the results will be confounded when the analyst applies the conventional M&V method. In this study, we demonstrated that switchable interventions, such as most HVAC control retrofits, can benefit from a new M&V method that randomly samples whether to implement the baseline or the intervention strategy at a fixed interval (e.g., daily). We tested this novel randomized M&V method on a large public dataset (hourly energy data over 2 years for 639 buildings) covering various climate zones and commercial building types, using a virtual chilled water supply temperature reset based on outdoor weather as the intervention. The results show that, compared to the conventional method, the randomized method provides more accurate savings estimations with a median of 74% accuracy improvement and is faster (typically 36 weeks instead of 104 weeks, ∼65% reduction in duration). Additionally, we found that when non-routine events are present (e.g., occupancy pattern change), the randomized method estimates savings that are much closer to the ground-truth values than the conventional method, demonstrating significantly improved reliability. We also assessed the impact of normalizing for different weather, starting the M&V at different dates of the year, continuing randomization with a different sampling ratio after satisfying all stopping criteria, and dropping samples affected by carryover effects when switching between strategies. For each scenario, we identified the optimal sampling interval using the large dataset. • Randomized switchback method improved measurement and verification accuracy. • Randomized switchback reduced uncertainty and shortened evaluation time. • Operational drift and non-routine events can strongly affect conventional savings estimates. • Longer sampling intervals reduced carryover effect but increased sampling error. • Favoring intervention in sampling increased error and uncertainty.

Authors

Institutions

Publication Details

Journal
Applied Energy
Published
2026-04-01
DOI
https://doi.org/10.1016/j.apenergy.2026.127784
Primary Topic
Building Energy and Comfort Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Demonstrating the reliability of randomized measurement and verification for switchable control retrofits using a large open-source dataset

Gail Brager, Paul Raftery, Carlos Duarte, Stefano Schiavon et al.
Applied Energy
Building Energy and Comfort Optimization
article

Demonstrating the reliability of randomized measurement and verification for switchable control retrofits using a large open-source dataset

Gail Brager, Paul Raftery, Carlos Duarte, Stefano Schiavon, Aoyu Zou
article en

Abstract

Conventional measurement and verification (M&V) methods for estimating energy savings rely on comparing pre- and post-retrofit performance. They are often time-consuming and unreliable, especially when non-routine events, such as step changes or more gradual changes in building operation, occur during the M&V process. When those events are unrelated to the retrofit intervention and significantly affect building energy consumption, the results will be confounded when the analyst applies the conventional M&V method. In this study, we demonstrated that switchable interventions, such as most HVAC control retrofits, can benefit from a new M&V method that randomly samples whether to implement the baseline or the intervention strategy at a fixed interval (e.g., daily). We tested this novel randomized M&V method on a large public dataset (hourly energy data over 2 years for 639 buildings) covering various climate zones and commercial building types, using a virtual chilled water supply temperature reset based on outdoor weather as the intervention. The results show that, compared to the conventional method, the randomized method provides more accurate savings estimations with a median of 74% accuracy improvement and is faster (typically 36 weeks instead of 104 weeks, ∼65% reduction in duration). Additionally, we found that when non-routine events are present (e.g., occupancy pattern change), the randomized method estimates savings that are much closer to the ground-truth values than the conventional method, demonstrating significantly improved reliability. We also assessed the impact of normalizing for different weather, starting the M&V at different dates of the year, continuing randomization with a different sampling ratio after satisfying all stopping criteria, and dropping samples affected by carryover effects when switching between strategies. For each scenario, we identified the optimal sampling interval using the large dataset. • Randomized switchback method improved measurement and verification accuracy. • Randomized switchback reduced uncertainty and shortened evaluation time. • Operational drift and non-routine events can strongly affect conventional savings estimates. • Longer sampling intervals reduced carryover effect but increased sampling error. • Favoring intervention in sampling increased error and uncertainty.

Applied EnergyVol. 413
Berkeley College (US), University of California, Berkeley (US)
Affordable and clean energy
Openalex Percentile: Top 7%
Building Energy and Comfort Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.