Application of advanced non-destructive testing for detection of corrosion-induced damage in graphene oxide based concrete composite

The early detection and evaluation of corrosion-induced damage and cracking in concrete structural members in real-time is of significant importance to reduce the risk of the catastrophic failure. For this purpose, this paper describes the application of an advanced non-destructive testing approach known as piezoelectric transducer-based electro-mechanical impedance (EMI) technique to the detection of corrosion-induced damage in graphene oxide based concrete composite (GOCC) sample in real-time. Firstly, the GOCC cube samples were prepared with 0, 0.01, 0.02, 0.03, 0.04 and 0.05% percentages of graphene oxide (GO) by weight of cement to estimate the compressive strength. Further, GOCC cylindrical samples were prepared for the optimum percentage of GO for the detection and evaluation of corrosion-induced damage using embedded piezo sensor (EPS). The changes in resonance peak, amplitude, root-mean square deviation (RMSD) and deterioration in terms of equivalent stiffness were estimated by performing the qualitative, quantitative and equivalent stiffness parameters analyses. Furthermore, gravimetric analysis was performed to identify the corrosion rate and correlated with the EMI results. The findings and analysis from compressive strength testing results indicates that at 0.03% of GO, concrete attains its maximum compressive strength. The EPS effectively captured the changes in the initiation phase of corrosion in terms of frequency and amplitude shifts. On comparison between CC and GOCC, it is found that CC shows a rapid stiffness loss (48%) compared to GOCC (40%) in first 10 days. The equivalent stiffness parameter provides a clear indication of corrosion-induced damage in GOCC. CC samples exhibited severe corrosion and cracked after around 60 days (1440 h), whereas GOCC delayed cracking to up to 82 days (1968 h), indicating around 37% longer corrosion initiation time. Additionally, GOCC exhibited (20-25) % lower mass loss and (35–40) % reduced corrosion rates compared to CC, demonstrating enhanced corrosion resistance. Overall, GOCC exhibited better corrosion resistance than conventional concrete, with reduced rust formation.

Authors

Institutions

Publication Details

Journal
Hybrid Advances
Published
2026-03-31
DOI
https://doi.org/10.1016/j.hybadv.2026.100652
Citations
1
Primary Topic
Concrete Corrosion and Durability
Type
article
Field-Weighted Citation Impact
11.50
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Application of advanced non-destructive testing for detection of corrosion-induced damage in graphene oxide based concrete composite

Tushar Bansal, Jai Srivastava
1 citations
Hybrid Advances
Concrete Corrosion and Durability
11.50
article

Application of advanced non-destructive testing for detection of corrosion-induced damage in graphene oxide based concrete composite

Tushar Bansal, Jai Srivastava
article en
1 citations

Abstract

The early detection and evaluation of corrosion-induced damage and cracking in concrete structural members in real-time is of significant importance to reduce the risk of the catastrophic failure. For this purpose, this paper describes the application of an advanced non-destructive testing approach known as piezoelectric transducer-based electro-mechanical impedance (EMI) technique to the detection of corrosion-induced damage in graphene oxide based concrete composite (GOCC) sample in real-time. Firstly, the GOCC cube samples were prepared with 0, 0.01, 0.02, 0.03, 0.04 and 0.05% percentages of graphene oxide (GO) by weight of cement to estimate the compressive strength. Further, GOCC cylindrical samples were prepared for the optimum percentage of GO for the detection and evaluation of corrosion-induced damage using embedded piezo sensor (EPS). The changes in resonance peak, amplitude, root-mean square deviation (RMSD) and deterioration in terms of equivalent stiffness were estimated by performing the qualitative, quantitative and equivalent stiffness parameters analyses. Furthermore, gravimetric analysis was performed to identify the corrosion rate and correlated with the EMI results. The findings and analysis from compressive strength testing results indicates that at 0.03% of GO, concrete attains its maximum compressive strength. The EPS effectively captured the changes in the initiation phase of corrosion in terms of frequency and amplitude shifts. On comparison between CC and GOCC, it is found that CC shows a rapid stiffness loss (48%) compared to GOCC (40%) in first 10 days. The equivalent stiffness parameter provides a clear indication of corrosion-induced damage in GOCC. CC samples exhibited severe corrosion and cracked after around 60 days (1440 h), whereas GOCC delayed cracking to up to 82 days (1968 h), indicating around 37% longer corrosion initiation time. Additionally, GOCC exhibited (20-25) % lower mass loss and (35–40) % reduced corrosion rates compared to CC, demonstrating enhanced corrosion resistance. Overall, GOCC exhibited better corrosion resistance than conventional concrete, with reduced rust formation.

Hybrid AdvancesVol. 13
Sharda University (IN)
Sustainable cities and communities
Openalex Percentile: Top 1%
Concrete Corrosion and Durability
11.50
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.