Spatially Resolved Inactivation of Escherichia coli in a RF (13.56 MHz) Capacitively Coupled Air Plasma at 4.0 mbar

A spatially resolved investigation of bacterial inactivation using a radiofrequency (13.56 MHz) capacitively coupled plasma (RF CCP) discharge operating in ambient air at 4.0 mbar is presented. The plasma was generated in a parallel-plate reactor without external gas precursors and characterized using Langmuir probe diagnostics and optical emission spectroscopy (OES). Electron densities on the order of 109 cm3 were measured near the powered electrode, exhibiting pronounced axial and radial gradients across the discharge volume. OES revealed strong excitation of oxygen- and nitrogen-containing emitters, including O I (777 nm), N2 s positive system (337–380 nm), and N2+ first negative system features, with emission intensities increasing monotonically with applied RF power. The bactericidal performance was evaluated using Escherichia coli American Type Culture Collection (ATCC) 11775 exposed at different axial and radial positions within the reactor. At a fixed exposure time of 60 s, the log10 reduction increased nonlinearly with RF power, rising from 0.29 at 20 W to 0.81 at 40 W, followed by a sharp transition to the assay reporting ceiling (≥2.95-log10 under the adopted half-count correction) at 50 W and above. Time-resolved measurements at 50 W demonstrated rapid inactivation kinetics, with measurable reductions occurring within 5–10 s and reaching the reporting ceiling within 60 s. In contrast, samples positioned at the chamber periphery or approximately 20 cm from the discharge center exhibited negligible inactivation, confirming strong spatial localization of the biocidal effect. These results identify a threshold-like operating regime in which increased discharge intensity produces rapid inactivation in the plasma core while remaining strongly position dependent. The findings establish medium pressure, air-based RF CCP as an efficient, gas-free, and spatially controllable platform for localized surface decontamination under non-thermal conditions.

Authors

Institutions

Publication Details

Journal
Plasma
Published
2026-03-31
DOI
https://doi.org/10.3390/plasma9020010
Primary Topic
Plasma Applications and Diagnostics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Spatially Resolved Inactivation of Escherichia coli in a RF (13.56 MHz) Capacitively Coupled Air Plasma at 4.0 mbar

Layla S. Nasser, Elias Naser, Batool Abulwahab, Fatima Makhlooq
Plasma
Plasma Applications and Diagnostics
article

Spatially Resolved Inactivation of Escherichia coli in a RF (13.56 MHz) Capacitively Coupled Air Plasma at 4.0 mbar

Layla S. Nasser, Elias Naser, Batool Abulwahab, Fatima Makhlooq
article en

Abstract

A spatially resolved investigation of bacterial inactivation using a radiofrequency (13.56 MHz) capacitively coupled plasma (RF CCP) discharge operating in ambient air at 4.0 mbar is presented. The plasma was generated in a parallel-plate reactor without external gas precursors and characterized using Langmuir probe diagnostics and optical emission spectroscopy (OES). Electron densities on the order of 109 cm3 were measured near the powered electrode, exhibiting pronounced axial and radial gradients across the discharge volume. OES revealed strong excitation of oxygen- and nitrogen-containing emitters, including O I (777 nm), N2 s positive system (337–380 nm), and N2+ first negative system features, with emission intensities increasing monotonically with applied RF power. The bactericidal performance was evaluated using Escherichia coli American Type Culture Collection (ATCC) 11775 exposed at different axial and radial positions within the reactor. At a fixed exposure time of 60 s, the log10 reduction increased nonlinearly with RF power, rising from 0.29 at 20 W to 0.81 at 40 W, followed by a sharp transition to the assay reporting ceiling (≥2.95-log10 under the adopted half-count correction) at 50 W and above. Time-resolved measurements at 50 W demonstrated rapid inactivation kinetics, with measurable reductions occurring within 5–10 s and reaching the reporting ceiling within 60 s. In contrast, samples positioned at the chamber periphery or approximately 20 cm from the discharge center exhibited negligible inactivation, confirming strong spatial localization of the biocidal effect. These results identify a threshold-like operating regime in which increased discharge intensity produces rapid inactivation in the plasma core while remaining strongly position dependent. The findings establish medium pressure, air-based RF CCP as an efficient, gas-free, and spatially controllable platform for localized surface decontamination under non-thermal conditions.

PlasmaVol. 9(2)
University of Bahrain (BH), Salmaniya Medical Complex (BH)
Openalex Percentile: Top 33%
Plasma Applications and Diagnostics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.