Determination of factors that allow cryogenic nanoscopy with high power illumination without devitrification

Cryogenic fluorescence nanoscopy, also known as super-resolution fluorescence light microscopy, has been demonstrated to be useful to close the resolution gap in cryogenic correlative light and electron microscopy (CLEM). Importantly, under cryogenic conditions fundamental resolution barriers that are imposed by molecular motion and photobleaching on fluorescence microscopy are circumvented. Due to combination of intrinsically higher resolution on the one hand with strong photobleaching and slower acquisition speed on the other hand, nanoscopy methods show the greatest resolution gain under cryogenic conditions. Therefore, cryogenic fluorescence nanoscopy has great potential also beyond CLEM. However, cryogenic nanoscopy is often limited by heating of the sample through strong laser irradiation. If the sample is heated above the glass transition temperature, diffusion and conformational changes perturb the sample and the sample eventually devitrifies. Reported tolerable power densities on different systems vary by several orders of magnitude. We therefore investigated the laser-induced heating in different setups for cryogenic nanoscopy by time-dependent finite-element simulations complemented with absorption measurements of mammalian cells. This showed that laser-induced heating happens in milliseconds in these setups, precluding efficient sample preservation by intermittent illuminations unless the laser power is modulated in the kHz regime. Under moderate (kW/cm2) light densities used for single molecule localization microscopy, absorbance by mammalian cells was too weak to explain devitrification. Here, heating is governed by absorption of supporting material and can therefore be alleviated by optimizing this material. However, the much higher power densities used in stimulated emission depletion nanoscopy (MW/cm2) resulted in temperatures clearly above the devitrification temperature from absorption by cells alone. Therefore, samples should be mounted on an efficient heat exchanger, such as a diamond, for high power illumination schemes.

Authors

Institutions

Publication Details

Journal
PLoS ONE
Published
2026-03-31
DOI
https://doi.org/10.1371/journal.pone.0344631
Primary Topic
Advanced Fluorescence Microscopy Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Determination of factors that allow cryogenic nanoscopy with high power illumination without devitrification

Jan Huebinger, Philippe I.H. Bastiaens
PLoS ONE
Advanced Fluorescence Microscopy Techniques
article

Determination of factors that allow cryogenic nanoscopy with high power illumination without devitrification

Jan Huebinger, Philippe I.H. Bastiaens
article en

Abstract

Cryogenic fluorescence nanoscopy, also known as super-resolution fluorescence light microscopy, has been demonstrated to be useful to close the resolution gap in cryogenic correlative light and electron microscopy (CLEM). Importantly, under cryogenic conditions fundamental resolution barriers that are imposed by molecular motion and photobleaching on fluorescence microscopy are circumvented. Due to combination of intrinsically higher resolution on the one hand with strong photobleaching and slower acquisition speed on the other hand, nanoscopy methods show the greatest resolution gain under cryogenic conditions. Therefore, cryogenic fluorescence nanoscopy has great potential also beyond CLEM. However, cryogenic nanoscopy is often limited by heating of the sample through strong laser irradiation. If the sample is heated above the glass transition temperature, diffusion and conformational changes perturb the sample and the sample eventually devitrifies. Reported tolerable power densities on different systems vary by several orders of magnitude. We therefore investigated the laser-induced heating in different setups for cryogenic nanoscopy by time-dependent finite-element simulations complemented with absorption measurements of mammalian cells. This showed that laser-induced heating happens in milliseconds in these setups, precluding efficient sample preservation by intermittent illuminations unless the laser power is modulated in the kHz regime. Under moderate (kW/cm2) light densities used for single molecule localization microscopy, absorbance by mammalian cells was too weak to explain devitrification. Here, heating is governed by absorption of supporting material and can therefore be alleviated by optimizing this material. However, the much higher power densities used in stimulated emission depletion nanoscopy (MW/cm2) resulted in temperatures clearly above the devitrification temperature from absorption by cells alone. Therefore, samples should be mounted on an efficient heat exchanger, such as a diamond, for high power illumination schemes.

PLoS ONEVol. 21(3)
TU Dortmund University (DE), Max Planck Institute of Molecular Physiology (DE)
Openalex Percentile: Top 34%
Advanced Fluorescence Microscopy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.