Direct Electrochemical Determination of Quercetin in Onion Samples Using Vertically Ordered Mesoporous Silica Films

ABSTRACT Quercetin (Qu), a dietary flavonoid with potent antioxidant and bioactive properties, requires accurate quantitation in food matrices to ensure health benefits and consumer safety. Conventional determination methods often suffer from high cost, complex operation, or susceptibility to electrode fouling. Herein, we report a high‐performance electrochemical sensor for Qu detection, employing nitrogen‐doped graphene quantum dots (NGQDs)‐electrochemically reduced graphene oxide (ErGO) nanocomposite integrated with vertically‐ordered mesoporous silica films (VMSF). This work distinguishes itself by uniquely combining the signal‐amplifying NGQDs‐ErGO nanocomposite with the antifouling VMSF nanochannels in a single in situ fabrication step, achieving both high sensitivity and exceptional robustness for direct detection in complex samples. The NGQDs‐graphene oxide (GO) nanocomposite was dropped onto gold electrodes (AuE), followed by in situ reduction of GO to ErGO during rapid VMSF growth via electrochemically assisted self‐assembly method. The synergistic combination of NGQDs and ErGO provides enhanced conductivity, abundant active sites, and improved analyte enrichment, while VMSF nanochannels confer strong anti‐fouling capabilities, molecular selectivity and preconcentration ability for Qu through hydrogen bonding effect. The developed VMSF/NGQDs‐ErGO/AuE sensor demonstrated excellent analytical performance, featuring a low detection limit of 61 nM, a high sensitivity of 1.37 µA/µM, and two wide linear ranges of 0.1–10 µM and 10–100 µM. It also showed outstanding reproducibility and stability for direct Qu detection in complex onion samples, with minimal interference from coexisting species. This strategy offers a versatile platform for antioxidant monitoring, quality control, and safety assurance in the food industry.

Authors

Institutions

Publication Details

Journal
ChemistrySelect
Published
2026-03-31
DOI
https://doi.org/10.1002/slct.202507430
Citations
1
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
11.61

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Direct Electrochemical Determination of Quercetin in Onion Samples Using Vertically Ordered Mesoporous Silica Films

Fengna Xi, Shuai Gu, Yekai Shao
1 citations
ChemistrySelect
Electrochemical sensors and biosensors
11.61
article

Direct Electrochemical Determination of Quercetin in Onion Samples Using Vertically Ordered Mesoporous Silica Films

Fengna Xi, Shuai Gu, Yekai Shao
article en
1 citations

Abstract

ABSTRACT Quercetin (Qu), a dietary flavonoid with potent antioxidant and bioactive properties, requires accurate quantitation in food matrices to ensure health benefits and consumer safety. Conventional determination methods often suffer from high cost, complex operation, or susceptibility to electrode fouling. Herein, we report a high‐performance electrochemical sensor for Qu detection, employing nitrogen‐doped graphene quantum dots (NGQDs)‐electrochemically reduced graphene oxide (ErGO) nanocomposite integrated with vertically‐ordered mesoporous silica films (VMSF). This work distinguishes itself by uniquely combining the signal‐amplifying NGQDs‐ErGO nanocomposite with the antifouling VMSF nanochannels in a single in situ fabrication step, achieving both high sensitivity and exceptional robustness for direct detection in complex samples. The NGQDs‐graphene oxide (GO) nanocomposite was dropped onto gold electrodes (AuE), followed by in situ reduction of GO to ErGO during rapid VMSF growth via electrochemically assisted self‐assembly method. The synergistic combination of NGQDs and ErGO provides enhanced conductivity, abundant active sites, and improved analyte enrichment, while VMSF nanochannels confer strong anti‐fouling capabilities, molecular selectivity and preconcentration ability for Qu through hydrogen bonding effect. The developed VMSF/NGQDs‐ErGO/AuE sensor demonstrated excellent analytical performance, featuring a low detection limit of 61 nM, a high sensitivity of 1.37 µA/µM, and two wide linear ranges of 0.1–10 µM and 10–100 µM. It also showed outstanding reproducibility and stability for direct Qu detection in complex onion samples, with minimal interference from coexisting species. This strategy offers a versatile platform for antioxidant monitoring, quality control, and safety assurance in the food industry.

ChemistrySelectVol. 11(13)
Zhejiang Sci-Tech University (CN)
National Natural Science Foundation of China
Openalex Percentile: Top 2%
Electrochemical sensors and biosensors
11.61
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Direct Electrochemical Determination of Quercetin in Onion Samples Using Vertically Ordered Mesoporous Silica Films — Fengna Xi, Shuai Gu, et al. · ChemistrySelect (2026) | TGRS Research Map | TGRS