Radiation Exposure and Safety in Minimally Invasive Foot and Ankle Surgery: A Comparative Analysis Between Minimally Invasive Distal First Metatarsal Transverse Osteotomy and Akin Osteotomy vs. Open Modified Lapidus Procedure

BACKGROUND: Intraoperative fluoroscopy has become essential in orthopaedic surgery, particularly with the rise of minimally invasive surgery (MIS) techniques. As MIS techniques depend more on intraoperative imaging, MIS techniques may necessitate increased fluoroscopy use compared with open procedures. Despite the advantages of minimally invasive foot and ankle surgery, MIS techniques raise concerns about radiation exposure to both patients and surgical staff. The purpose of this study was to evaluate fluoroscopy time and radiation dose (cumulative air kerma) associated with open versus MIS bunion correction, comparing the open modified Lapidus procedure and the minimally invasive distal first metatarsal transverse osteotomy and akin osteotomy (META). It was hypothesized that the META procedure would be associated with increased radiation dose and fluoroscopy time compared with the open modified Lapidus procedure. METHODS: A retrospective review was conducted for patients who underwent bunion surgery between January 2021 and June 2025 by two fellowship-trained orthopaedic foot and ankle surgeons at a single academic institution. A total of 294 patients met inclusion criteria. Of these, 258 patients underwent a META procedure and 36 underwent an open modified Lapidus procedure. Fluoroscopy time (minutes) and radiation dose (mGy) were compared between the groups. RESULTS: A mean fluoroscopy time of 2.13 ± 1.27 (range, 0.06 to 7.05) minutes and a radiation dose of 2.02 ± 1.30 (range, 0.05 to 7.52) mGy were observed in the META cohort. An average fluoroscopy time of 1.63 ± 1.83 (range, 0.08 to 7.70) minutes and a radiation dose of 1.31 ± 1.43 (range, 0.07 to 5.98) mGy were observed in the open modified Lapidus cohort. Fluoroscopy time between the cohorts did not differ markedly ( P = 0.123); however, the META group demonstrated a higher radiation dose than the open modified Lapidus group ( P = 0.007). CONCLUSION: The META procedure had a markedly higher radiation dose compared with the open modified Lapidus procedure, although both remain substantially below the International Commission on Radiological Protection recommended occupational exposure of less than 20.00 mSv per year. Despite the META procedure generating an average radiation dose of 2.02 mGy per case, surgeons receive only 0.50% of the dose; thus, nearly 1,980 procedures would be required to exceed the 20.00 mSv annual occupational limit. These findings suggest that concerns about radiation exposure should not necessarily deter providers from performing the META technique for bunion correction. LEVEL OF EVIDENCE: III (Retrospective Comparative Study).

Authors

Institutions

Publication Details

Journal
Journal of the American Academy of Orthopaedic Surgeons
Published
2026-04-01
DOI
https://doi.org/10.5435/jaaos-d-25-01325
Primary Topic
Foot and Ankle Surgery
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Radiation Exposure and Safety in Minimally Invasive Foot and Ankle Surgery: A Comparative Analysis Between Minimally Invasive Distal First Metatarsal Transverse Osteotomy and Akin Osteotomy vs. Open Modified Lapidus Procedure

Moawiah S. Mustafa, Preston E. Harrison, Oliver N. Schipper, Ettore Vulcano et al.
Journal of the American Academy of Orthopaedic Surgeons
Foot and Ankle Surgery
article

Radiation Exposure and Safety in Minimally Invasive Foot and Ankle Surgery: A Comparative Analysis Between Minimally Invasive Distal First Metatarsal Transverse Osteotomy and Akin Osteotomy vs. Open Modified Lapidus Procedure

Moawiah S. Mustafa, Preston E. Harrison, Oliver N. Schipper, Ettore Vulcano, Jonathan Kaplan, Sarah Hall Kiriluk, Shawn Guirau, J. Benjamin Jackson, A. Holly Johnson, John O'Keefe, Kevin Lee, Tyler A. Gonzalez
article en

Abstract

BACKGROUND: Intraoperative fluoroscopy has become essential in orthopaedic surgery, particularly with the rise of minimally invasive surgery (MIS) techniques. As MIS techniques depend more on intraoperative imaging, MIS techniques may necessitate increased fluoroscopy use compared with open procedures. Despite the advantages of minimally invasive foot and ankle surgery, MIS techniques raise concerns about radiation exposure to both patients and surgical staff. The purpose of this study was to evaluate fluoroscopy time and radiation dose (cumulative air kerma) associated with open versus MIS bunion correction, comparing the open modified Lapidus procedure and the minimally invasive distal first metatarsal transverse osteotomy and akin osteotomy (META). It was hypothesized that the META procedure would be associated with increased radiation dose and fluoroscopy time compared with the open modified Lapidus procedure. METHODS: A retrospective review was conducted for patients who underwent bunion surgery between January 2021 and June 2025 by two fellowship-trained orthopaedic foot and ankle surgeons at a single academic institution. A total of 294 patients met inclusion criteria. Of these, 258 patients underwent a META procedure and 36 underwent an open modified Lapidus procedure. Fluoroscopy time (minutes) and radiation dose (mGy) were compared between the groups. RESULTS: A mean fluoroscopy time of 2.13 ± 1.27 (range, 0.06 to 7.05) minutes and a radiation dose of 2.02 ± 1.30 (range, 0.05 to 7.52) mGy were observed in the META cohort. An average fluoroscopy time of 1.63 ± 1.83 (range, 0.08 to 7.70) minutes and a radiation dose of 1.31 ± 1.43 (range, 0.07 to 5.98) mGy were observed in the open modified Lapidus cohort. Fluoroscopy time between the cohorts did not differ markedly ( P = 0.123); however, the META group demonstrated a higher radiation dose than the open modified Lapidus group ( P = 0.007). CONCLUSION: The META procedure had a markedly higher radiation dose compared with the open modified Lapidus procedure, although both remain substantially below the International Commission on Radiological Protection recommended occupational exposure of less than 20.00 mSv per year. Despite the META procedure generating an average radiation dose of 2.02 mGy per case, surgeons receive only 0.50% of the dose; thus, nearly 1,980 procedures would be required to exceed the 20.00 mSv annual occupational limit. These findings suggest that concerns about radiation exposure should not necessarily deter providers from performing the META technique for bunion correction. LEVEL OF EVIDENCE: III (Retrospective Comparative Study).

Journal of the American Academy of Orthopaedic Surgeons
Columbia University Irving Medical Center (US)
Openalex Percentile: Top 31%
Foot and Ankle Surgery
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.