Lipemia-induced pseudohyponatremia: Analytical bias beyond manufacturer claims

Background: Lipemia-induced sodium underestimation can introduce a clinically relevant analytic bias in sodium measurements. In this study, we aimed to evaluate the clinical impact of lipemia on sodium measurements, investigate thresholds for sodium underestimation due to lipemia, and compare manufacturer-recommended interference limits with actual clinical data. Methods: interference). The relationship between sodium bias (ΔNa) and lipemic index was assessed. Results: Intralipid®-spiked samples exceeded the analytical and CLIA limits at lipemic indices of ∼300 and ∼500, respectively, well below manufacturer-stated thresholds (>2000). In clinical samples, sodium bias was greater than in spiked plasma where ΔNa exceeded analytical limits at L-indices >100 and CLIA TEa at >200. Conclusions: interference experiments. We recommend that manufacturers update their interference studies, and that laboratories evaluate their lipemic thresholds through retrospective data analysis, in accordance with ISO 15189:2022.

Authors

Institutions

Publication Details

Journal
Practical Laboratory Medicine
Published
2026-03-31
DOI
https://doi.org/10.1016/j.plabm.2026.e00529
Primary Topic
Electrolyte and hormonal disorders
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Lipemia-induced pseudohyponatremia: Analytical bias beyond manufacturer claims

Nienke Geerts, Jeanne E. van Dongen, Volkher Scharnhorst
Practical Laboratory Medicine
Electrolyte and hormonal disorders
article

Lipemia-induced pseudohyponatremia: Analytical bias beyond manufacturer claims

Nienke Geerts, Jeanne E. van Dongen, Volkher Scharnhorst
article en

Abstract

Background: Lipemia-induced sodium underestimation can introduce a clinically relevant analytic bias in sodium measurements. In this study, we aimed to evaluate the clinical impact of lipemia on sodium measurements, investigate thresholds for sodium underestimation due to lipemia, and compare manufacturer-recommended interference limits with actual clinical data. Methods: interference). The relationship between sodium bias (ΔNa) and lipemic index was assessed. Results: Intralipid®-spiked samples exceeded the analytical and CLIA limits at lipemic indices of ∼300 and ∼500, respectively, well below manufacturer-stated thresholds (>2000). In clinical samples, sodium bias was greater than in spiked plasma where ΔNa exceeded analytical limits at L-indices >100 and CLIA TEa at >200. Conclusions: interference experiments. We recommend that manufacturers update their interference studies, and that laboratories evaluate their lipemic thresholds through retrospective data analysis, in accordance with ISO 15189:2022.

Practical Laboratory MedicineVol. 50
Radboud University Nijmegen (NL), Catharina Ziekenhuis (NL), Eindhoven University of Technology (NL)
Zero hunger
Openalex Percentile: Top 33%
Electrolyte and hormonal disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines