Energy Resilience in Water Treatment Infrastructure under Seasonal Hydrological Stress: Neural Network-controlled Solar Generation Integration in Southern Nigeria

Aims: This study quantifies the impact of seasonal hydrological variability on energy demand at the Cross River State Water Board (CRSWB) treatment facility in Calabar, Nigeria, and evaluates the effectiveness of neural network-controlled distributed solar generation (DSG) in enhancing grid resilience during turbidity-driven peak demand periods. Study Design: A quantitative, model-based case study using historical water quality and load profile data with MATLAB/Simulink and ETAP simulation over a three-year horizon (2013–2015). Place and Duration of Study: Cross River State Waterboard water treatment facility, Calabar, Nigeria; data collection 2013–2015, simulation conducted in 2024. Methodology: Turbidity records (NTU), hourly load profiles (kW), and plant operational data were obtained from CRSWB. Seasonal partitioning followed Nigerian hydrological cycles: dry season (November–March) and rainy season (April–October). Linear regression modelled the turbidity–energy relationship. A 33 kV network diagram in ETAP was reconfigured in MATLAB/Simulink to integrate a 217.12 kW solar PV unit. A Bayesian-regularized neural network (R = 0.991) automated DSG dispatch during peak hours (09:00–18:00). Validation employed two-sample and paired t-tests. Results: Dry-season turbidity peaked at 194 NTU versus 17 NTU in the rainy season. This 4.2-fold increase was associated with 23.5% higher daily energy demand (24,542 kW vs. 19,876 kW) and 45% greater load variability (σ = 142 kW vs. 98 kW). DSG integration reduced daily energy consumption by 9.1%, lowered peak demand by 30% (680 kW to 476 kW), and decreased load variability by 37% (σ = 89 kW). All differences were statistically significant (P < .001). Conclusion: Seasonal turbidity is a primary driver of energy demand instability in tropical water treatment infrastructure. Neural network-controlled solar DSG substantially mitigates peak demand and load variability, offering a replicable, evidence-based blueprint for energy-resilient water utilities across sub-Saharan Africa.

Authors

Institutions

Publication Details

Journal
Journal of Energy Research and Reviews
Published
2026-04-01
DOI
https://doi.org/10.9734/jenrr/2026/v18i4505
Primary Topic
Water-Energy-Food Nexus Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Energy Resilience in Water Treatment Infrastructure under Seasonal Hydrological Stress: Neural Network-controlled Solar Generation Integration in Southern Nigeria

ThankGod Sylvanus Ntem, Olumide Omojola, Nwandu Charles Arnold, O. Nwafor Christiana
Journal of Energy Research and Reviews
Water-Energy-Food Nexus Studies
article

Energy Resilience in Water Treatment Infrastructure under Seasonal Hydrological Stress: Neural Network-controlled Solar Generation Integration in Southern Nigeria

ThankGod Sylvanus Ntem, Olumide Omojola, Nwandu Charles Arnold, O. Nwafor Christiana
article en

Abstract

Aims: This study quantifies the impact of seasonal hydrological variability on energy demand at the Cross River State Water Board (CRSWB) treatment facility in Calabar, Nigeria, and evaluates the effectiveness of neural network-controlled distributed solar generation (DSG) in enhancing grid resilience during turbidity-driven peak demand periods. Study Design: A quantitative, model-based case study using historical water quality and load profile data with MATLAB/Simulink and ETAP simulation over a three-year horizon (2013–2015). Place and Duration of Study: Cross River State Waterboard water treatment facility, Calabar, Nigeria; data collection 2013–2015, simulation conducted in 2024. Methodology: Turbidity records (NTU), hourly load profiles (kW), and plant operational data were obtained from CRSWB. Seasonal partitioning followed Nigerian hydrological cycles: dry season (November–March) and rainy season (April–October). Linear regression modelled the turbidity–energy relationship. A 33 kV network diagram in ETAP was reconfigured in MATLAB/Simulink to integrate a 217.12 kW solar PV unit. A Bayesian-regularized neural network (R = 0.991) automated DSG dispatch during peak hours (09:00–18:00). Validation employed two-sample and paired t-tests. Results: Dry-season turbidity peaked at 194 NTU versus 17 NTU in the rainy season. This 4.2-fold increase was associated with 23.5% higher daily energy demand (24,542 kW vs. 19,876 kW) and 45% greater load variability (σ = 142 kW vs. 98 kW). DSG integration reduced daily energy consumption by 9.1%, lowered peak demand by 30% (680 kW to 476 kW), and decreased load variability by 37% (σ = 89 kW). All differences were statistically significant (P < .001). Conclusion: Seasonal turbidity is a primary driver of energy demand instability in tropical water treatment infrastructure. Neural network-controlled solar DSG substantially mitigates peak demand and load variability, offering a replicable, evidence-based blueprint for energy-resilient water utilities across sub-Saharan Africa.

Journal of Energy Research and ReviewsVol. 18(4)
Covenant University (NG), African Field Epidemiology Network (NG)
Openalex Percentile: Top 37%
Water-Energy-Food Nexus Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.