Monitoring Inputs, Control Architectures, and Failure Modes in Closed-Loop Vasopressor Systems: A Comprehensive Review

Closed-loop vasopressor systems integrate real-time blood pressure monitoring with automated decision logic to support hemodynamic stability in perioperative and critical care environments. These technologies sit at the intersection of biomedical sensing, signal processing, and clinician-supervised automation: the quality, latency, and failure behavior of the monitoring input can directly shape controller performance, safety margins, and clinical usability. In this comprehensive review, we synthesize the major closed-loop vasopressor architectures reported in the literature, examine how sensor modality and signal integrity influence algorithm behavior, and summarize recurrent reliability vulnerabilities spanning sensors, control logic, and device integration. We organize the field through an end-to-end information pipeline-monitoring input, signal conditioning and quality assessment, decision and control strategy, actuation via infusion technology, and supervisory safety layers-highlighting common performance metrics used to benchmark control quality. We then discuss clinical validation patterns across settings, emphasizing practical considerations for deployment and the evidence gaps that remain most relevant to high-risk populations. Finally, we propose reporting and validation priorities for future studies, with a focus on sensor robustness, transparency of algorithm design, integration safeguards, and standardized documentation of failures and overrides.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2026-04-01
DOI
https://doi.org/10.3390/s26072180
Primary Topic
Healthcare Technology and Patient Monitoring
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Monitoring Inputs, Control Architectures, and Failure Modes in Closed-Loop Vasopressor Systems: A Comprehensive Review

Hiorrana Sousa Dias, Carlos Darcy Alves Bersot, Bruno Francisco Minetto Wegner, Marcos Adriano Lessa et al.
Sensors
Healthcare Technology and Patient Monitoring
article

Monitoring Inputs, Control Architectures, and Failure Modes in Closed-Loop Vasopressor Systems: A Comprehensive Review

Hiorrana Sousa Dias, Carlos Darcy Alves Bersot, Bruno Francisco Minetto Wegner, Marcos Adriano Lessa, Gabriel Lemos Gonzalez, Gustavo Wegner, Gustavo Guimaraes Torres, Vitor Alves Felippe
article en

Abstract

Closed-loop vasopressor systems integrate real-time blood pressure monitoring with automated decision logic to support hemodynamic stability in perioperative and critical care environments. These technologies sit at the intersection of biomedical sensing, signal processing, and clinician-supervised automation: the quality, latency, and failure behavior of the monitoring input can directly shape controller performance, safety margins, and clinical usability. In this comprehensive review, we synthesize the major closed-loop vasopressor architectures reported in the literature, examine how sensor modality and signal integrity influence algorithm behavior, and summarize recurrent reliability vulnerabilities spanning sensors, control logic, and device integration. We organize the field through an end-to-end information pipeline-monitoring input, signal conditioning and quality assessment, decision and control strategy, actuation via infusion technology, and supervisory safety layers-highlighting common performance metrics used to benchmark control quality. We then discuss clinical validation patterns across settings, emphasizing practical considerations for deployment and the evidence gaps that remain most relevant to high-risk populations. Finally, we propose reporting and validation priorities for future studies, with a focus on sensor robustness, transparency of algorithm design, integration safeguards, and standardized documentation of failures and overrides.

SensorsVol. 26(7)
University of Iowa (US), Universidade Federal do Rio Grande do Sul (BR), Universidade Federal da Fronteira Sul (BR), Hospital Universitário Pedro Ernesto (BR), Universidade Paulista (BR), Unichristus (BR), Prefeitura Municipal de Campos dos Goytacazes (BR), Instituto Nacional de Câncer - INCA (BR), Universidade Federal do Estado do Rio de Janeiro (BR), Universidade Estadual Paulista (Unesp) (BR)
Peace, Justice and strong institutions
Openalex Percentile: Top 37%
Healthcare Technology and Patient Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.