From Force Plates to AI: Establishing Validity and Reliability of a 2D AI-Camera System for Quantifying Sit-to-Stand Power Measurement

BACKGROUND: ) using body mass, stature, chair height, and performance time via a validated equation. The criterion method computed power from average peak vertical ground-reaction forces and IMU-derived vertical displacement. Concurrent validity between AI and criterion power was assessed using Pearson's correlation coefficient (r) with 95% confidence intervals (CI) and Bland-Altman analysis. Test-retest reliability for AI and criterion measures was evaluated using a two-way mixed-effects intraclass correlation coefficient (ICC(3,1)) with 95% CI, and measurement error was quantified via the standard error of measurement (SEM) and minimal detectable change at 95% confidence (MDC₉₅). RESULTS: (31.6%). CONCLUSION: The findings of this study support the use of a 2D AI-camera system as a valid and highly reliable tool for quantifying muscle power during the 30-second Sit to Stand Power Test. The 2D AI-camera system offers a promising solution for scalable, objective performance testing in clinical and remote settings.

Authors

Institutions

Publication Details

Journal
International Journal of Sports Physical Therapy
Published
2026-04-01
DOI
https://doi.org/10.26603/001c.158667
Primary Topic
Balance, Gait, and Falls Prevention
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

From Force Plates to AI: Establishing Validity and Reliability of a 2D AI-Camera System for Quantifying Sit-to-Stand Power Measurement

Michael Jeanfavre, Joy Xiao
International Journal of Sports Physical Therapy
Balance, Gait, and Falls Prevention
article

From Force Plates to AI: Establishing Validity and Reliability of a 2D AI-Camera System for Quantifying Sit-to-Stand Power Measurement

Michael Jeanfavre, Joy Xiao
article en

Abstract

BACKGROUND: ) using body mass, stature, chair height, and performance time via a validated equation. The criterion method computed power from average peak vertical ground-reaction forces and IMU-derived vertical displacement. Concurrent validity between AI and criterion power was assessed using Pearson's correlation coefficient (r) with 95% confidence intervals (CI) and Bland-Altman analysis. Test-retest reliability for AI and criterion measures was evaluated using a two-way mixed-effects intraclass correlation coefficient (ICC(3,1)) with 95% CI, and measurement error was quantified via the standard error of measurement (SEM) and minimal detectable change at 95% confidence (MDC₉₅). RESULTS: (31.6%). CONCLUSION: The findings of this study support the use of a 2D AI-camera system as a valid and highly reliable tool for quantifying muscle power during the 30-second Sit to Stand Power Test. The 2D AI-camera system offers a promising solution for scalable, objective performance testing in clinical and remote settings.

International Journal of Sports Physical TherapyVol. 21(4)
Duke University (US), Stanford Health Care (US)
Openalex Percentile: Top 26%
Balance, Gait, and Falls Prevention
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.