Does EyeKinetix pupillometry clarify RAPD detection?

PURPOSE: To evaluate variability observed in pupil light response with the EyeKinetix pupillometer in healthy non-dark-adapted individuals. METHODS: We performed objective pupillometry in 440 non-dark-adapted patients with 20/20 corrected visual acuity, normal visual fields, and no ophthalmic disease who presented for routine exam. EyeKinetix was performed as part of the routine exam screening protocol. Metrics reviewed were RAPDx amplitude scores, latency scores, and quantitative metrics of pupil dynamics measured by the EyeKinetix. Sequential retesting was analyzed for repeatability. Statistical analyses included normality testing, confidence intervals, t-tests, and Intraclass Correlation Coefficient (ICC) calculations for repeated measures. RESULTS: Amplitude and latency scores exhibited significant variability. The mean amplitude score was 0.0249 ± 0.247, with 5% of patients > = 2 standard deviations [> 0.51 log unit (LU)]. Latency scores showed low reliability (ICC = 0.165), whereas amplitude, constriction velocity, and release velocity demonstrated moderate to high reliability (ICC = 0.472-0.966). CONCLUSION: Objective pupillometry without dark adaptation using the EyeKinetix device displays substantial variability and identifies a number of relative afferent pupil defects (RAPDs) in this cohort of healthy patients. These findings indicate that, in healthy populations, reliance on RAPDx scores alone could generate false positives. Establishing robust normative cutoffs and validating them in disease cohorts will be necessary before reliable use as a screener. Further optimization may be necessary for more clinical confidence in a primary care setting.

Authors

Institutions

Publication Details

Journal
Documenta Ophthalmologica
Published
2026-04-01
DOI
https://doi.org/10.1007/s10633-026-10097-8
Primary Topic
Ocular Surface and Contact Lens
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Does EyeKinetix pupillometry clarify RAPD detection?

Carl J. Bassi, Mark A. Kahrhoff
Documenta Ophthalmologica
Ocular Surface and Contact Lens
article

Does EyeKinetix pupillometry clarify RAPD detection?

Carl J. Bassi, Mark A. Kahrhoff
article en

Abstract

PURPOSE: To evaluate variability observed in pupil light response with the EyeKinetix pupillometer in healthy non-dark-adapted individuals. METHODS: We performed objective pupillometry in 440 non-dark-adapted patients with 20/20 corrected visual acuity, normal visual fields, and no ophthalmic disease who presented for routine exam. EyeKinetix was performed as part of the routine exam screening protocol. Metrics reviewed were RAPDx amplitude scores, latency scores, and quantitative metrics of pupil dynamics measured by the EyeKinetix. Sequential retesting was analyzed for repeatability. Statistical analyses included normality testing, confidence intervals, t-tests, and Intraclass Correlation Coefficient (ICC) calculations for repeated measures. RESULTS: Amplitude and latency scores exhibited significant variability. The mean amplitude score was 0.0249 ± 0.247, with 5% of patients > = 2 standard deviations [> 0.51 log unit (LU)]. Latency scores showed low reliability (ICC = 0.165), whereas amplitude, constriction velocity, and release velocity demonstrated moderate to high reliability (ICC = 0.472-0.966). CONCLUSION: Objective pupillometry without dark adaptation using the EyeKinetix device displays substantial variability and identifies a number of relative afferent pupil defects (RAPDs) in this cohort of healthy patients. These findings indicate that, in healthy populations, reliance on RAPDx scores alone could generate false positives. Establishing robust normative cutoffs and validating them in disease cohorts will be necessary before reliable use as a screener. Further optimization may be necessary for more clinical confidence in a primary care setting.

Documenta Ophthalmologica
Washington University in St. Louis (US), University of Missouri–St. Louis (US), Webster University (US)
Openalex Percentile: Top 27%
Ocular Surface and Contact Lens
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Does EyeKinetix pupillometry clarify RAPD detection? — Carl J. Bassi, Mark A. Kahrhoff · Documenta Ophthalmologica (2026) | TGRS Research Map | TGRS