Dual-layer smart coating system with a hybrid corrosion inhibitor for improved durability of carbon steel pipeline

This study aims to develop a hybrid dual-layer smart coating system incorporating multiple corrosion inhibitors to enhance the durability and corrosion resistance of carbon steel substrates. The proposed system consists of a hydrophobic zinc oxide–stearic acid (ZnO-STA) top layer and a self-healing epoxy bottom layer containing benzotriazole-loaded halloysite nanotubes (BTA-HNT) and boiled linseed oil microcapsules (BLO-MC). Five coating systems were fabricated, including pure epoxy, conventional dual-layer coating, and hybrid dual-layer coatings with ZnO-to-epoxy ratios of 2:1, 4:1, and 6:1. Structural and chemical characteristics were verified using Fourier Transform Infrared Spectroscopy (FTIR) and Scanning Electron Microscopy with Energy Dispersive X-ray Spectroscopy. At the same time, corrosion performance was evaluated using Electrochemical Impedance Spectroscopy and scratch tests over 2 weeks of immersion in 3.5 wt.% NaCl solution. The results indicate that the hybrid coating with a ZnO: epoxy ratio of 4:1 exhibited the best corrosion resistance, maintaining impedance values between 4.45 Ω and 4.16 Ω at low frequency and showing the lowest corrosion area of 4.4% after 2 weeks of exposure. However, the hybrid coatings demonstrated reduced adhesion strength, approximately 77.30% lower than the conventional dual-layer coating. Overall, the integration of ZnO-STA, BTA-HNT, and BLO-MC in a hybrid dual-layer system enhances corrosion protection through synergistic hydrophobic barrier and self-healing mechanisms. However, further optimisation is required to improve coating adhesion for long-term application.

Authors

Institutions

Publication Details

Journal
JOURNAL OF MECHANICAL ENGINEERING AND SCIENCES
Published
2026-03-31
DOI
https://doi.org/10.15282/jmes.20.1.2026.8.0868
Primary Topic
Corrosion Behavior and Inhibition
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Dual-layer smart coating system with a hybrid corrosion inhibitor for improved durability of carbon steel pipeline

Rohah A. Majid, Shahrulzaman Shaharuddin, Fathin Hani Azizul Rahim, Puteri Sri Melor Megat Yusoff et al.
JOURNAL OF MECHANICAL ENGINEERING AND SCIENCES
Corrosion Behavior and Inhibition
article

Dual-layer smart coating system with a hybrid corrosion inhibitor for improved durability of carbon steel pipeline

Rohah A. Majid, Shahrulzaman Shaharuddin, Fathin Hani Azizul Rahim, Puteri Sri Melor Megat Yusoff, Siti Haslina Ramli, Nuur Fahanis Che Lah, Kirsheela Jayabalan
article en

Abstract

This study aims to develop a hybrid dual-layer smart coating system incorporating multiple corrosion inhibitors to enhance the durability and corrosion resistance of carbon steel substrates. The proposed system consists of a hydrophobic zinc oxide–stearic acid (ZnO-STA) top layer and a self-healing epoxy bottom layer containing benzotriazole-loaded halloysite nanotubes (BTA-HNT) and boiled linseed oil microcapsules (BLO-MC). Five coating systems were fabricated, including pure epoxy, conventional dual-layer coating, and hybrid dual-layer coatings with ZnO-to-epoxy ratios of 2:1, 4:1, and 6:1. Structural and chemical characteristics were verified using Fourier Transform Infrared Spectroscopy (FTIR) and Scanning Electron Microscopy with Energy Dispersive X-ray Spectroscopy. At the same time, corrosion performance was evaluated using Electrochemical Impedance Spectroscopy and scratch tests over 2 weeks of immersion in 3.5 wt.% NaCl solution. The results indicate that the hybrid coating with a ZnO: epoxy ratio of 4:1 exhibited the best corrosion resistance, maintaining impedance values between 4.45 Ω and 4.16 Ω at low frequency and showing the lowest corrosion area of 4.4% after 2 weeks of exposure. However, the hybrid coatings demonstrated reduced adhesion strength, approximately 77.30% lower than the conventional dual-layer coating. Overall, the integration of ZnO-STA, BTA-HNT, and BLO-MC in a hybrid dual-layer system enhances corrosion protection through synergistic hydrophobic barrier and self-healing mechanisms. However, further optimisation is required to improve coating adhesion for long-term application.

JOURNAL OF MECHANICAL ENGINEERING AND SCIENCES
Petronas (Malaysia) (MY), Universiti Teknologi Petronas (MY), University of Kuala Lumpur (MY), University of Technology Malaysia (MY)
Universiti Teknologi Petronas, Yayasan UTP
Openalex Percentile: Top 37%
Corrosion Behavior and Inhibition
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.