Sampled-Data-Based Secondary Frequency Control for Fractional-Order Islanded Microgrid Subject to External Disturbance

The motivation for this paper is that most of the works on secondary frequency control are focused on conventional synchronous communication approaches. To extend this research, this paper investigates the sampled-data-based H∞ load frequency control (LFC) problem for fractional-order islanded microgrids under a multi-region communication scheme. In contrast to conventional synchronous communication approaches, the proposed scheme allows each regional sensor to operate asynchronously based on its own sampling interval. To model this multi-region communication mechanism, a unified sampling sequence is constructed by collecting all sampling instants from regional sensors. Accordingly, a closed-loop system model is established through the introduction of virtual state variables. Furthermore, a novel class of looped functionals is developed to fully exploit the sampling interval characteristics of each regional sensor. By employing inequality techniques and stability analysis, sufficient conditions are derived to achieve multi-region sampled-data-based H∞ LFC for fractional-order islanded microgrids. In addition, a co-design method is proposed to simultaneously determine the control gain and the maximum allowable sampling period. The simulations are conducted in MATLAB/Simulink (R2024a) and the LMI conditions are solved by using the LMI Toolbox and YALMIP. Finally, comprehensive simulations in MATLAB/Simulink validate the proposed scheme. For the two-region system, the method achieves a maximum sampling period of ζmax=0.106 s with an H∞ performance ratio of 2.87 (below γ=5) and settling times of 8.5 s and 9.2 s. Compared to synchronous sampling, it reduces the communication bandwidth by 50% for slower regions while maintaining comparable performance. For the single-region multi-rate case (0.104 s and 0.140 s sampling periods), the H∞ ratio is 3.12, also satisfying γ=5. The relationship between γ and ζmax is quantified: ζmax increases from 0.050 s to 0.106 s as γ increases from 3 to 5, confirming that relaxed disturbance attenuation allows larger sampling intervals.

Authors

Institutions

Publication Details

Journal
Fractal and Fractional
Published
2026-03-31
DOI
https://doi.org/10.3390/fractalfract10040233
Primary Topic
Frequency Control in Power Systems
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Sampled-Data-Based Secondary Frequency Control for Fractional-Order Islanded Microgrid Subject to External Disturbance

Shuxian Fan, Yongjie Shi
Fractal and Fractional
Frequency Control in Power Systems
article

Sampled-Data-Based Secondary Frequency Control for Fractional-Order Islanded Microgrid Subject to External Disturbance

Shuxian Fan, Yongjie Shi
article en

Abstract

The motivation for this paper is that most of the works on secondary frequency control are focused on conventional synchronous communication approaches. To extend this research, this paper investigates the sampled-data-based H∞ load frequency control (LFC) problem for fractional-order islanded microgrids under a multi-region communication scheme. In contrast to conventional synchronous communication approaches, the proposed scheme allows each regional sensor to operate asynchronously based on its own sampling interval. To model this multi-region communication mechanism, a unified sampling sequence is constructed by collecting all sampling instants from regional sensors. Accordingly, a closed-loop system model is established through the introduction of virtual state variables. Furthermore, a novel class of looped functionals is developed to fully exploit the sampling interval characteristics of each regional sensor. By employing inequality techniques and stability analysis, sufficient conditions are derived to achieve multi-region sampled-data-based H∞ LFC for fractional-order islanded microgrids. In addition, a co-design method is proposed to simultaneously determine the control gain and the maximum allowable sampling period. The simulations are conducted in MATLAB/Simulink (R2024a) and the LMI conditions are solved by using the LMI Toolbox and YALMIP. Finally, comprehensive simulations in MATLAB/Simulink validate the proposed scheme. For the two-region system, the method achieves a maximum sampling period of ζmax=0.106 s with an H∞ performance ratio of 2.87 (below γ=5) and settling times of 8.5 s and 9.2 s. Compared to synchronous sampling, it reduces the communication bandwidth by 50% for slower regions while maintaining comparable performance. For the single-region multi-rate case (0.104 s and 0.140 s sampling periods), the H∞ ratio is 3.12, also satisfying γ=5. The relationship between γ and ζmax is quantified: ζmax increases from 0.050 s to 0.106 s as γ increases from 3 to 5, confirming that relaxed disturbance attenuation allows larger sampling intervals.

Fractal and FractionalVol. 10(4)
Shandong University of Science and Technology (CN)
Natural Science Foundation of Qingdao
Openalex Percentile: Top 36%
Frequency Control in Power Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.