Development of FBG-Embedded Catheter for Identifying the Region of Vascular Stenosis

Catheter-based assessment and treatment of vascular stenosis are widely used. In this process, contrast media are commonly employed for accurate imaging diagnosis; however, the increased use of contrast media is associated with a higher risk of allergic reactions. In this study, we propose a method for identifying the site of vascular stenosis and evaluating treatment effectiveness using a catheter embedded with a fiber Bragg grating (FBG) sensor capable of measuring pressure differences, thereby reducing the reliance on contrast media. By simulating blood pressure distribution at the stenotic site, we confirmed that the pressure difference can be used to position the catheter accurately and assess treatment outcomes. Furthermore, we developed a prototype catheter with an embedded FBG sensor and demonstrated its pressure measurement capability in a fluid environment. Our analysis and experiments confirm that an FBG-embedded catheter can effectively identify vascular stenosis and quantify its severity.

Authors

Institutions

Publication Details

Journal
IEEJ Transactions on Sensors and Micromachines
Published
2026-03-31
DOI
https://doi.org/10.1541/ieejsmas.146.97
Primary Topic
Advanced Fiber Optic Sensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of FBG-Embedded Catheter for Identifying the Region of Vascular Stenosis

Yusaku Maeda, Kodai Hashimoto, Minami Kittaka
IEEJ Transactions on Sensors and Micromachines
Advanced Fiber Optic Sensors
article

Development of FBG-Embedded Catheter for Identifying the Region of Vascular Stenosis

Yusaku Maeda, Kodai Hashimoto, Minami Kittaka
article en

Abstract

Catheter-based assessment and treatment of vascular stenosis are widely used. In this process, contrast media are commonly employed for accurate imaging diagnosis; however, the increased use of contrast media is associated with a higher risk of allergic reactions. In this study, we propose a method for identifying the site of vascular stenosis and evaluating treatment effectiveness using a catheter embedded with a fiber Bragg grating (FBG) sensor capable of measuring pressure differences, thereby reducing the reliance on contrast media. By simulating blood pressure distribution at the stenotic site, we confirmed that the pressure difference can be used to position the catheter accurately and assess treatment outcomes. Furthermore, we developed a prototype catheter with an embedded FBG sensor and demonstrated its pressure measurement capability in a fluid environment. Our analysis and experiments confirm that an FBG-embedded catheter can effectively identify vascular stenosis and quantify its severity.

IEEJ Transactions on Sensors and MicromachinesVol. 146(4)
National Institute of Technology, Kagawa College (JP)
Good health and well-being
Openalex Percentile: Top 9%
Advanced Fiber Optic Sensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.