Detecting low left ventricular ejection fraction from ECG using an interpretable and scalable predictor-driven framework: a model development and validation study

Low left ventricular ejection fraction (LEF) frequently remains undetected until progression to symptomatic heart failure, underscoring the need for scalable screening strategies. Although artificial intelligence-enabled electrocardiography (AI-ECG) has shown promise, existing approaches rely solely on end-to-end black-box models with limited interpretability or on tabular systems dependent on commercial ECG measurement algorithms with suboptimal performance. We introduced ECG-based Predictor-Driven LEF (ECGPD-LEF), a structured framework that integrates foundation model-derived diagnostic probabilities with interpretable modeling for detecting LEF from ECG. Trained on the benchmark EchoNext dataset comprising 72,475 ECG-echocardiogram pairs and evaluated in predefined independent internal (n=5,442) and external (n=16,017) cohorts, our framework achieved robust discrimination for moderate LEF (internal AUROC 88.4%, F1 64.5%; external AUROC 86.8%, F1 53.6%), consistently outperforming the official end-to-end baseline provided with the benchmark across demographic and clinical subgroups. Interpretability analyses identified high-impact predictors, including normal ECG, incomplete left bundle branch block, and subendocardial injury in anterolateral leads, driving LEF risk estimation. Notably, these predictors independently enabled zero-shot-like inference without task-specific retraining (internal AUROC 75.3-81.0%; external AUROC 71.6-78.6%), indicating that ventricular dysfunction is intrinsically encoded within structured diagnostic probability representations. This framework reconciles predictive performance with mechanistic transparency, supporting scalable enhancement through additional predictors and seamless integration with existing AI-ECG systems.

Authors

Publication Details

Journal
EClinicalMedicine
Published
2026-11-14
DOI
https://doi.org/10.1016/j.eclinm.2026.104331
Primary Topic
ECG Monitoring and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Detecting low left ventricular ejection fraction from ECG using an interpretable and scalable predictor-driven framework: a model development and validation study

Haojie Zhu, Tianxiang Hao, Jing Yuan, Jia Liu et al.
6 links
EClinicalMedicine
ECG Monitoring and Analysis
article

Detecting low left ventricular ejection fraction from ECG using an interpretable and scalable predictor-driven framework: a model development and validation study

Haojie Zhu, Tianxiang Hao, Jing Yuan, Jia Liu, Ya Zhou, Ziyi Cai, Xiaohan Fan, Hejun He
article en

Abstract

Low left ventricular ejection fraction (LEF) frequently remains undetected until progression to symptomatic heart failure, underscoring the need for scalable screening strategies. Although artificial intelligence-enabled electrocardiography (AI-ECG) has shown promise, existing approaches rely solely on end-to-end black-box models with limited interpretability or on tabular systems dependent on commercial ECG measurement algorithms with suboptimal performance. We introduced ECG-based Predictor-Driven LEF (ECGPD-LEF), a structured framework that integrates foundation model-derived diagnostic probabilities with interpretable modeling for detecting LEF from ECG. Trained on the benchmark EchoNext dataset comprising 72,475 ECG-echocardiogram pairs and evaluated in predefined independent internal (n=5,442) and external (n=16,017) cohorts, our framework achieved robust discrimination for moderate LEF (internal AUROC 88.4%, F1 64.5%; external AUROC 86.8%, F1 53.6%), consistently outperforming the official end-to-end baseline provided with the benchmark across demographic and clinical subgroups. Interpretability analyses identified high-impact predictors, including normal ECG, incomplete left bundle branch block, and subendocardial injury in anterolateral leads, driving LEF risk estimation. Notably, these predictors independently enabled zero-shot-like inference without task-specific retraining (internal AUROC 75.3-81.0%; external AUROC 71.6-78.6%), indicating that ventricular dysfunction is intrinsically encoded within structured diagnostic probability representations. This framework reconciles predictive performance with mechanistic transparency, supporting scalable enhancement through additional predictors and seamless integration with existing AI-ECG systems.

EClinicalMedicineVol. 102
Good health and well-being
ECG Monitoring and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon