Luminescence of bandpass dichroic filters within their transmission band can result in misinterpretation of experimental data

In this paper, we considered the autoluminescence of three IR bandpass dichroic filters, occurring in their transmission bands under excitation in visible, as a potential source of erroneous interpretation of experimental results. An interference filter with the transmission band centered at 1270 nm, used for the detection of singlet oxygen phosphorescence, and two other IR filters with the transmission bands centered at 1064 and 1047 nm were under study. All three filters were shown to emit noticeable luminescence within their transmission bands under excitation at 405, 440, 510, and 660 nm. The determined luminescence decay times varied from 0.1 to >20 μs and depended on the excitation wavelength. The results obtained suggest that this potential parasitic luminescence should be carefully taken into account in experiments with low-intensity luminescence signals because its underestimation can corrupt the interpretation of the experimental data.

Authors

Institutions

Publication Details

Journal
Review of Scientific Instruments
Published
2026-04-01
DOI
https://doi.org/10.1063/5.0300693
Primary Topic
Luminescence Properties of Advanced Materials
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Luminescence of bandpass dichroic filters within their transmission band can result in misinterpretation of experimental data

V. P. Belik, D. M. Beltukova, O. S. Vasyutinskii, O. V. Smirnov et al.
Review of Scientific Instruments
Luminescence Properties of Advanced Materials
article

Luminescence of bandpass dichroic filters within their transmission band can result in misinterpretation of experimental data

V. P. Belik, D. M. Beltukova, O. S. Vasyutinskii, O. V. Smirnov, I. V. Semenova
article en

Abstract

In this paper, we considered the autoluminescence of three IR bandpass dichroic filters, occurring in their transmission bands under excitation in visible, as a potential source of erroneous interpretation of experimental results. An interference filter with the transmission band centered at 1270 nm, used for the detection of singlet oxygen phosphorescence, and two other IR filters with the transmission bands centered at 1064 and 1047 nm were under study. All three filters were shown to emit noticeable luminescence within their transmission bands under excitation at 405, 440, 510, and 660 nm. The determined luminescence decay times varied from 0.1 to >20 μs and depended on the excitation wavelength. The results obtained suggest that this potential parasitic luminescence should be carefully taken into account in experiments with low-intensity luminescence signals because its underestimation can corrupt the interpretation of the experimental data.

Review of Scientific InstrumentsVol. 97(4)
Ioffe Institute (RU)
Openalex Percentile: Top 29%
Luminescence Properties of Advanced Materials
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Luminescence of bandpass dichroic filters within their transmission band can result in misinterpretation of experimental data — V. P. Belik, D. M. Beltukova, et al. · Review of Scientific Instruments (2026) | TGRS Research Map | TGRS