Evaluating the Use of a Thermoelectric Module Cooling to Increase the Power Density of Power Converters

This paper starts by analysing the equivalent circuit model of a Thermoelectric Module (TEM) with PLECS simulation by using the PLECS thermal block-set. The approach enables the evaluation of power-module losses when mounted on a sandwich assembly of a TEM, heatsink, and cooling fan. An experimental setup was first built using power resistors for controlled heat generation to be absorbed by the cooling system and validated with the simulation model. Experimental investigations were then carried out on a DC/DC converter under four cooling conditions: natural convection and forced convection without a TEM and then natural convection and forced convection with a TEM. The experimental results are validated using PLECS Software (version 4.8). This result demonstrates a reduction in the power-module junction temperature of the DC/DC converter when employing forced convection with a TEM compared to forced convection without a TEM. Furthermore, the results indicate about 32% potential weight and size reduction of the converter magnetic components, along with improved power density, through the integration of TEM-based cooling.

Authors

Institutions

Publication Details

Journal
Energies
Published
2026-03-31
DOI
https://doi.org/10.3390/en19071709
Primary Topic
Advanced Thermoelectric Materials and Devices
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluating the Use of a Thermoelectric Module Cooling to Increase the Power Density of Power Converters

Patrick Wheeler, Christian Klumpner, Abdullahi Abubakar
Energies
Advanced Thermoelectric Materials and Devices
article

Evaluating the Use of a Thermoelectric Module Cooling to Increase the Power Density of Power Converters

Patrick Wheeler, Christian Klumpner, Abdullahi Abubakar
article en

Abstract

This paper starts by analysing the equivalent circuit model of a Thermoelectric Module (TEM) with PLECS simulation by using the PLECS thermal block-set. The approach enables the evaluation of power-module losses when mounted on a sandwich assembly of a TEM, heatsink, and cooling fan. An experimental setup was first built using power resistors for controlled heat generation to be absorbed by the cooling system and validated with the simulation model. Experimental investigations were then carried out on a DC/DC converter under four cooling conditions: natural convection and forced convection without a TEM and then natural convection and forced convection with a TEM. The experimental results are validated using PLECS Software (version 4.8). This result demonstrates a reduction in the power-module junction temperature of the DC/DC converter when employing forced convection with a TEM compared to forced convection without a TEM. Furthermore, the results indicate about 32% potential weight and size reduction of the converter magnetic components, along with improved power density, through the integration of TEM-based cooling.

EnergiesVol. 19(7)
Ahmadu Bello University (NG), University of Nottingham (GB)
European Commission, Petroleum Technology Development Fund
Affordable and clean energy
Openalex Percentile: Top 38%
Advanced Thermoelectric Materials and Devices
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.