Development of a high-precision evaluation system for radial pulse wave applanation tonometry devices

The demand for wearable devices for daily health management and tonometry-based pulse wave measurement has grown rapidly. However, the absence of standardized and physiologically realistic evaluation systems remains a major barrier to developing reliable and clinically applicable devices. Although ISO 18615:2020 defines general performance requirements for electronic radial pulse tonometric devices, no evaluation platform has been available to assess these standards with higher precision. We developed a novel high-precision evaluation system that integrates a 3D cam-based pulse wave generation unit, wrist simulation unit, system control unit, and applied pressure unit. This platform enables controlled and reproducible simulation of physiological pulse waves, including variations in base pressure, pulse pressure, applied pressure, and radial skin and arterial properties, which have been difficult to replicate in previous systems. The system was designed not only to meet but also to exceed ISO 18,615 requirements, thereby enabling precise performance assessment. Validation experiments evaluated pulse wave precision and range, as well as artificial radial artery characteristics. The system demonstrated high reproducibility and accuracy. The mean coefficients of variation (CVs) were 0.29% for applied pressure, 0.11% for pulse waves, and 0.05% for pulse rate. The CVs of pulse wave shape parameters H and T were 1.06% and 1.60%, respectively. The systole/diastole ratio (SDR) ranged from 24.45% to 57.69% with a 1.04% error ratio, the pulse rate from 19.93 bpm to 204.90 bpm with a 0.34% error ratio, and the base pressure from − 3.17 mmHg to 116.51 mmHg with a 3.60% error ratio. This study presents the first comprehensive evaluation platform capable of reproducing physiologically realistic radial arterial pulse waves with high precision and reproducibility. By referencing and surpassing ISO 18,615 performance requirements, the system provides rigorous and reliable assessment of device performance. This platform reduces variability, enables precise calibration, and offers a benchmark for evaluating tonometry-based and wearable pulse wave measurement devices. It is expected to accelerate the development of high-quality cardiovascular monitoring technologies and support the clinical translation of wearable health monitoring devices.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2026-03-31
DOI
https://doi.org/10.1038/s41598-026-45661-4
Primary Topic
Photoacoustic and Ultrasonic Imaging
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of a high-precision evaluation system for radial pulse wave applanation tonometry devices

Min‐Ho Jun, Seunghwan Choy, Young-Min Kim
Scientific Reports
Photoacoustic and Ultrasonic Imaging
article

Development of a high-precision evaluation system for radial pulse wave applanation tonometry devices

Min‐Ho Jun, Seunghwan Choy, Young-Min Kim
article en

Abstract

The demand for wearable devices for daily health management and tonometry-based pulse wave measurement has grown rapidly. However, the absence of standardized and physiologically realistic evaluation systems remains a major barrier to developing reliable and clinically applicable devices. Although ISO 18615:2020 defines general performance requirements for electronic radial pulse tonometric devices, no evaluation platform has been available to assess these standards with higher precision. We developed a novel high-precision evaluation system that integrates a 3D cam-based pulse wave generation unit, wrist simulation unit, system control unit, and applied pressure unit. This platform enables controlled and reproducible simulation of physiological pulse waves, including variations in base pressure, pulse pressure, applied pressure, and radial skin and arterial properties, which have been difficult to replicate in previous systems. The system was designed not only to meet but also to exceed ISO 18,615 requirements, thereby enabling precise performance assessment. Validation experiments evaluated pulse wave precision and range, as well as artificial radial artery characteristics. The system demonstrated high reproducibility and accuracy. The mean coefficients of variation (CVs) were 0.29% for applied pressure, 0.11% for pulse waves, and 0.05% for pulse rate. The CVs of pulse wave shape parameters H and T were 1.06% and 1.60%, respectively. The systole/diastole ratio (SDR) ranged from 24.45% to 57.69% with a 1.04% error ratio, the pulse rate from 19.93 bpm to 204.90 bpm with a 0.34% error ratio, and the base pressure from − 3.17 mmHg to 116.51 mmHg with a 3.60% error ratio. This study presents the first comprehensive evaluation platform capable of reproducing physiologically realistic radial arterial pulse waves with high precision and reproducibility. By referencing and surpassing ISO 18,615 performance requirements, the system provides rigorous and reliable assessment of device performance. This platform reduces variability, enables precise calibration, and offers a benchmark for evaluating tonometry-based and wearable pulse wave measurement devices. It is expected to accelerate the development of high-quality cardiovascular monitoring technologies and support the clinical translation of wearable health monitoring devices.

Scientific Reports
Korea Institute of Oriental Medicine (KR)
Ministry of Food and Drug Safety, Korea Institute of Oriental Medicine
Affordable and clean energy
Openalex Percentile: Top 15%
Photoacoustic and Ultrasonic Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.