Estimation of the Knee Joint with Single-Camera Smartphone

(1) Background: Gait analysis provides quantitative information on walking patterns and has proven invaluable for assessing motor function in rehabilitation programmes. A markerless motion capture system combining computer vision techniques provides low-cost, real-time, portable gait analysis. (2) Methods: The kinematics of the knee and ankle of twenty-seven healthy volunteers were assessed using a single smartphone camera combined with the MediaPipe human pose estimation framework. The system was validated using the OPAL wearable sensor system by APDM Wearable Technologies. (3) Results: Findings showed close correspondence between the two systems for knee kinematics showing a mean absolute error of 4.10° ± 2.32° and 3.15° ± 3.10° for right and left knee flexion, respectively, and a mean absolute error of 2.30° ± 2.01° and 3.12° ± 2.63° for right and left knee extension, respectively. The mean absolute error for right and left knee range of motion was found to be 4.55° ± 3.12° and 4.15° ± 3.01°, respectively. Moreover, Bland-Altman plots indicated minimal bias (average 0.6 for flexion, average 0.47 for the extension, and 0.30 for the range of motion) and excellent correlation for knee flexion bilaterally (0.916 and 0.845 for the right and left side, respectively), with slightly lower but still satisfactory agreement for knee extension (0.862 and 0.845 for the right and left side, respectively). Conversely, ankle measurements revealed poor concordance: dorsiflexion and range of motion presented significant differences and systematic errors, while plantarflexion showed no statistical difference but weak correlation. (4) Conclusions: This study demonstrated that combining a smartphone camera with a human pose estimation framework allows for low-cost, real-time, portable gait analysis, particularly of the knee joint.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2026-03-31
DOI
https://doi.org/10.3390/s26072148
Primary Topic
Balance, Gait, and Falls Prevention
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Estimation of the Knee Joint with Single-Camera Smartphone

Maria Francesca Spadea, Michela Russo, Alfonso Maria Ponsiglione, Vittorio Santoriello et al.
Sensors
Balance, Gait, and Falls Prevention
article

Estimation of the Knee Joint with Single-Camera Smartphone

Maria Francesca Spadea, Michela Russo, Alfonso Maria Ponsiglione, Vittorio Santoriello, Carlo Ricciardi, Maria Romano, Francesco Amato
article en

Abstract

(1) Background: Gait analysis provides quantitative information on walking patterns and has proven invaluable for assessing motor function in rehabilitation programmes. A markerless motion capture system combining computer vision techniques provides low-cost, real-time, portable gait analysis. (2) Methods: The kinematics of the knee and ankle of twenty-seven healthy volunteers were assessed using a single smartphone camera combined with the MediaPipe human pose estimation framework. The system was validated using the OPAL wearable sensor system by APDM Wearable Technologies. (3) Results: Findings showed close correspondence between the two systems for knee kinematics showing a mean absolute error of 4.10° ± 2.32° and 3.15° ± 3.10° for right and left knee flexion, respectively, and a mean absolute error of 2.30° ± 2.01° and 3.12° ± 2.63° for right and left knee extension, respectively. The mean absolute error for right and left knee range of motion was found to be 4.55° ± 3.12° and 4.15° ± 3.01°, respectively. Moreover, Bland-Altman plots indicated minimal bias (average 0.6 for flexion, average 0.47 for the extension, and 0.30 for the range of motion) and excellent correlation for knee flexion bilaterally (0.916 and 0.845 for the right and left side, respectively), with slightly lower but still satisfactory agreement for knee extension (0.862 and 0.845 for the right and left side, respectively). Conversely, ankle measurements revealed poor concordance: dorsiflexion and range of motion presented significant differences and systematic errors, while plantarflexion showed no statistical difference but weak correlation. (4) Conclusions: This study demonstrated that combining a smartphone camera with a human pose estimation framework allows for low-cost, real-time, portable gait analysis, particularly of the knee joint.

SensorsVol. 26(7)
Karlsruhe Institute of Technology (DE), Reykjavík University (IS), University of Naples Federico II (IT)
European Commission
No poverty
Openalex Percentile: Top 34%
Balance, Gait, and Falls Prevention
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.