Reliability Enhancement of an 11kV Distribution Network Using Optimally Placed Hybrid Distributed Generation

This paper presents a comprehensive techno‑analytical investigation into the impact of optimally placed hybrid distributed generation (DG) on the reliability performance of a medium‑voltage distribution network. A practical 11‑kV radial feeder in Edo State, Nigeria, supplying 2.01 MW of connected load, was used as the case study. In the base‑case condition, load‑flow and reliability analysis in ETAP yielded minimum bus voltages of 0.912 pu, total real power losses of 186.4 kW, and poor reliability indices of SAIFI = 13.58 interruptions/customer‑year, SAIDI = 49.35 hours/customer‑year, CAIDI = 3.63 hours/interruption and EENS = 314.74 MWh/year. Using a Genetic Algorithm implemented in MATLAB, two hybrid solar–wind DG units of optimal capacities 480 kW and 350 kW were allocated at Bus 9 and Bus 12, respectively. After DG integration, the minimum bus voltage improved to 0.981 pu, real power losses reduced to 74.2 kW (60.2% reduction), and reliability indices improved to SAIFI = 6.60 interruptions/customer‑year, SAIDI = 40.01 hours/customer‑year, CAIDI = 6.06 hours/interruption and EENS = 71.98 MWh/year, corresponding to a 77.1% reduction in energy not supplied. The results demonstrate that optimally placed hybrid renewable DG provides an effective technical solution for enhancing voltage stability, reducing losses and significantly improving service continuity in weak radial distribution networks.

Publication Details

Journal
Iconic Research and Engineering Journals
Published
2026-03-31
DOI
https://doi.org/10.64388/irev9i9-1715520
Primary Topic
Optimal Power Flow Distribution
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Reliability Enhancement of an 11kV Distribution Network Using Optimally Placed Hybrid Distributed Generation

Iconic Research and Engineering Journals
Optimal Power Flow Distribution
article

Reliability Enhancement of an 11kV Distribution Network Using Optimally Placed Hybrid Distributed Generation

article en

Abstract

This paper presents a comprehensive techno‑analytical investigation into the impact of optimally placed hybrid distributed generation (DG) on the reliability performance of a medium‑voltage distribution network. A practical 11‑kV radial feeder in Edo State, Nigeria, supplying 2.01 MW of connected load, was used as the case study. In the base‑case condition, load‑flow and reliability analysis in ETAP yielded minimum bus voltages of 0.912 pu, total real power losses of 186.4 kW, and poor reliability indices of SAIFI = 13.58 interruptions/customer‑year, SAIDI = 49.35 hours/customer‑year, CAIDI = 3.63 hours/interruption and EENS = 314.74 MWh/year. Using a Genetic Algorithm implemented in MATLAB, two hybrid solar–wind DG units of optimal capacities 480 kW and 350 kW were allocated at Bus 9 and Bus 12, respectively. After DG integration, the minimum bus voltage improved to 0.981 pu, real power losses reduced to 74.2 kW (60.2% reduction), and reliability indices improved to SAIFI = 6.60 interruptions/customer‑year, SAIDI = 40.01 hours/customer‑year, CAIDI = 6.06 hours/interruption and EENS = 71.98 MWh/year, corresponding to a 77.1% reduction in energy not supplied. The results demonstrate that optimally placed hybrid renewable DG provides an effective technical solution for enhancing voltage stability, reducing losses and significantly improving service continuity in weak radial distribution networks.

Iconic Research and Engineering JournalsVol. 9(9)
Affordable and clean energy
Openalex Percentile: Top 10%
Optimal Power Flow Distribution
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Reliability Enhancement of an 11kV Distribution Network Using Optimally Placed Hybrid Distributed Generation · Iconic Research and Engineering Journals (2026) | TGRS Research Map | TGRS