Influence of Barrier Membrane and Peri‐Implantitis‐Like Bone Defect Configurations on Graft Stability

OBJECTIVES: The objective of this ex vivo investigation was to study the significance of barrier membrane application on graft stability across different peri-implantitis-related bone defect configurations. MATERIALS AND METHODS: Fresh pig mandibles were used to create standardized peri-implant-like bone defects, including dehiscence defects, 2-3 wall defects, and circumferential defects. Defects were treated using identical grafting and flap closure protocols, with or without barrier membrane application. High-resolution cone-beam computed tomography (CBCT) scans were obtained before flap closure, after primary closure, and following simulated soft-tissue movement in order to analyze graft material thickness at multiple predefined levels along the implant surface. Changes in graft thickness over time were analyzed using generalized estimating equation (GEE) linear regression models. RESULTS: A total of 120 bone augmentation procedures in 20 pig hemimandibles were analyzed. In dehiscence defect morphologies, graft thickness decreased significantly over time, with the greatest dimensional changes occurring immediately after primary wound closure (GEE main effect of TIME, p < 0.001). In these defects, pronounced coronal (platform level) graft displacement was observed, with thickness reductions of approximately 1.2-1.4 mm after closure and total reductions exceeding 85% following simulated soft-tissue movement. Barrier membrane application did not prevent graft collapse nor modify the coronal temporal pattern; however, it resulted in a limited attenuation of graft loss at selected middle levels (approximately 0.15-0.25 mm, corresponding to 5%-15% relative reduction). In 2-3 wall defects, graft thickness also decreased significantly over time across all evaluated levels (p < 0.001), with membrane application consistently attenuating early graft displacement at coronal and middle levels. In contrast, circumferential defects demonstrated high intrinsic dimensional stability, with minimal dimensional changes over time (< 0.1 mm) and no significant membrane-related effects. Across defect types exhibiting graft displacement, coronal measurements consistently showed the greatest susceptibility to thickness reduction. CONCLUSION: Graft stability following reconstructive therapy of peri-implantitis-like bone defects is primarily influenced by defect morphology. Hence, the effect of barrier membrane coverage appears to be defect-dependent. Membrane application provides limited attenuation of graft displacement in 2-3 wall defects while no consistent or clinically meaningful additional effect is observed in dehiscence or circumferential defects.

Authors

Institutions

Publication Details

Journal
Clinical Implant Dentistry and Related Research
Published
2026-03-31
DOI
https://doi.org/10.1111/cid.70140
Primary Topic
Dental Implant Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Influence of Barrier Membrane and Peri‐Implantitis‐Like Bone Defect Configurations on Graft Stability

Gonzalo Blasi, Emilio Couso‐Queiruga, Fernando Suárez, Alberto Monje et al.
Clinical Implant Dentistry and Related Research
Dental Implant Techniques and Outcomes
article

Influence of Barrier Membrane and Peri‐Implantitis‐Like Bone Defect Configurations on Graft Stability

Gonzalo Blasi, Emilio Couso‐Queiruga, Fernando Suárez, Alberto Monje, Jorge Osorio
article en

Abstract

OBJECTIVES: The objective of this ex vivo investigation was to study the significance of barrier membrane application on graft stability across different peri-implantitis-related bone defect configurations. MATERIALS AND METHODS: Fresh pig mandibles were used to create standardized peri-implant-like bone defects, including dehiscence defects, 2-3 wall defects, and circumferential defects. Defects were treated using identical grafting and flap closure protocols, with or without barrier membrane application. High-resolution cone-beam computed tomography (CBCT) scans were obtained before flap closure, after primary closure, and following simulated soft-tissue movement in order to analyze graft material thickness at multiple predefined levels along the implant surface. Changes in graft thickness over time were analyzed using generalized estimating equation (GEE) linear regression models. RESULTS: A total of 120 bone augmentation procedures in 20 pig hemimandibles were analyzed. In dehiscence defect morphologies, graft thickness decreased significantly over time, with the greatest dimensional changes occurring immediately after primary wound closure (GEE main effect of TIME, p < 0.001). In these defects, pronounced coronal (platform level) graft displacement was observed, with thickness reductions of approximately 1.2-1.4 mm after closure and total reductions exceeding 85% following simulated soft-tissue movement. Barrier membrane application did not prevent graft collapse nor modify the coronal temporal pattern; however, it resulted in a limited attenuation of graft loss at selected middle levels (approximately 0.15-0.25 mm, corresponding to 5%-15% relative reduction). In 2-3 wall defects, graft thickness also decreased significantly over time across all evaluated levels (p < 0.001), with membrane application consistently attenuating early graft displacement at coronal and middle levels. In contrast, circumferential defects demonstrated high intrinsic dimensional stability, with minimal dimensional changes over time (< 0.1 mm) and no significant membrane-related effects. Across defect types exhibiting graft displacement, coronal measurements consistently showed the greatest susceptibility to thickness reduction. CONCLUSION: Graft stability following reconstructive therapy of peri-implantitis-like bone defects is primarily influenced by defect morphology. Hence, the effect of barrier membrane coverage appears to be defect-dependent. Membrane application provides limited attenuation of graft displacement in 2-3 wall defects while no consistent or clinically meaningful additional effect is observed in dehiscence or circumferential defects.

Clinical Implant Dentistry and Related ResearchVol. 28(2)
University of Bern (CH), University of Iowa (US), Bern University of Applied Sciences (CH), Universitat Internacional de Catalunya (ES), Universidad Católica de Santiago de Guayaquil (EC), Centro de Implantología Cirugía Oral y Maxilofacial (ES)
Openalex Percentile: Top 30%
Dental Implant Techniques and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.