Detail preservation sparse-view CT image reconstruction via range-null space decomposition based diffusion priors

BackgroundSparse-view CT reduces radiation dose by decreasing the number of projections, yet the resulting undersampling introduces severe artifacts in images reconstructed with traditional analytical algorithms. Recent diffusion posterior sampling (DPS)-based methods enhance image quality but frequently generate spurious details and incur prohibitive computational cost, limiting clinical adoption.ObjectiveTo enable high-fidelity, low-dose CT imaging from sparse projections while suppressing hallucinated details and reducing computational burden.MethodsWe propose a novel diffusion-based method that synergizes null-space restoration with Filtered Back-Projection (FBP) pseudoinverse approximation. Specifically, by employing range-null space decomposition, we use diffusion models to restore null-space image components while ensuring data consistency through the FBP algorithm approximating the pseudoinverse of projection matrix in the range image space. Moreover, we provide a theoretical analysis of the rationality of this approximation. This novel approach effectively combines the strengths of diffusion models and traditional CT reconstruction techniques, optimizing the inverse diffusion trajectory to enable high-fidelity image recovery from sparse data.ResultsExperimental results show that the proposed method achieves significant improvements in image quality and computational efficiency. Compared with the DPS method, it yields an average PSNR gain of 5.32 dB, an average SSIM increase of 0.083, and a 41.9% reduction in computation time.ConclusionIn summary, this framework provides a practical and effective solution for high-quality, low-dose CT imaging, effectively balancing reconstruction accuracy and computational efficiency in practical applications.

Authors

Institutions

Publication Details

Journal
Journal of X-Ray Science and Technology
Published
2026-03-31
DOI
https://doi.org/10.1177/08953996261432977
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Detail preservation sparse-view CT image reconstruction via range-null space decomposition based diffusion priors

Ailong Cai, Qiaofang Xing, Lei Li, Bin Yan et al.
Journal of X-Ray Science and Technology
Medical Imaging Techniques and Applications
article

Detail preservation sparse-view CT image reconstruction via range-null space decomposition based diffusion priors

Ailong Cai, Qiaofang Xing, Lei Li, Bin Yan, Zhizhong Zheng
article en

Abstract

BackgroundSparse-view CT reduces radiation dose by decreasing the number of projections, yet the resulting undersampling introduces severe artifacts in images reconstructed with traditional analytical algorithms. Recent diffusion posterior sampling (DPS)-based methods enhance image quality but frequently generate spurious details and incur prohibitive computational cost, limiting clinical adoption.ObjectiveTo enable high-fidelity, low-dose CT imaging from sparse projections while suppressing hallucinated details and reducing computational burden.MethodsWe propose a novel diffusion-based method that synergizes null-space restoration with Filtered Back-Projection (FBP) pseudoinverse approximation. Specifically, by employing range-null space decomposition, we use diffusion models to restore null-space image components while ensuring data consistency through the FBP algorithm approximating the pseudoinverse of projection matrix in the range image space. Moreover, we provide a theoretical analysis of the rationality of this approximation. This novel approach effectively combines the strengths of diffusion models and traditional CT reconstruction techniques, optimizing the inverse diffusion trajectory to enable high-fidelity image recovery from sparse data.ResultsExperimental results show that the proposed method achieves significant improvements in image quality and computational efficiency. Compared with the DPS method, it yields an average PSNR gain of 5.32 dB, an average SSIM increase of 0.083, and a 41.9% reduction in computation time.ConclusionIn summary, this framework provides a practical and effective solution for high-quality, low-dose CT imaging, effectively balancing reconstruction accuracy and computational efficiency in practical applications.

Journal of X-Ray Science and Technology
PLA Information Engineering University (CN)
Sustainable cities and communities
Openalex Percentile: Top 24%
Medical Imaging Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Detail preservation sparse-view CT image reconstruction via range-null space decomposition based diffusion priors — Ailong Cai, Qiaofang Xing, et al. · Journal of X-Ray Science and Technology (2026) | TGRS Research Map | TGRS