Enhancing Heat Transfer in Turbulent Channel Flows: A Numerical Study on the Geometric and Orientational Effects of Delta, Trapezoidal, and Rectangular Winglet Vortex Generators

This paper presents a numerical study on the enhancement of heat transfer in a solar air heater (SAH) duct using winglet-type longitudinal vortex generators (WLVGs). Delta (DW), trapezoidal (TW1, TW2), and rectangular (RW) winglets are examined in pointing-up (PU) and pointing-down (PD) orientations, with the span-wise spacing ratio (S/H) varied to determine the optimal layout (S/H = 1.43, b/H = 0.50). Computational Fluid Dynamics (CFD) simulations using the GEKO turbulence model in ANSYS Fluent are performed for Reynolds numbers (Re) ranging from 5,000 to 22,500. Flow structures are analysed via Q-criterion isosurfaces, Nusselt number distributions, and streamwise vorticity contours. Results show that PU orientations generally outperform PD due to closer vortex–wall interaction. The RW configuration exhibits the highest Nusselt number, achieving a maximum Nusselt number of 114.37 at Re = 22,500, primarily attributed to the persistence of its generated vortices. However, it also results in the greatest frictional penalty, with a maximum friction factor of 0.1562 at Re = 5,000 and a corresponding normalized value of 𝑓/𝑓₀ = 5.21 at Re = 22,500. Consequently, the RW configuration yields the lowest thermal enhancement factor (TEF) at high Reynolds numbers, reaching a minimum value of 1.050 at Re = 22,500, despite its strong heat transfer rate. In contrast, the highest TEF is achieved with the PU TW1 configuration (TEF = 1.473 at Re = 5,000), which offers the most favourable balance between enhanced heat transfer and acceptable frictional losses. These results provide design-oriented implications for solar air heater (SAH) systems, identifying PU TW1 as the most energy-efficient configuration, whereas RW may be more suitable for applications where maximizing heat transfer rate is prioritised over minimising frictional losses.

Authors

Institutions

Publication Details

Journal
Hittite Journal of Science & Engineering
Published
2026-03-31
DOI
https://doi.org/10.17350/hjse19030000369
Primary Topic
Heat Transfer Mechanisms
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Enhancing Heat Transfer in Turbulent Channel Flows: A Numerical Study on the Geometric and Orientational Effects of Delta, Trapezoidal, and Rectangular Winglet Vortex Generators

Atila Abir İğci
Hittite Journal of Science & Engineering
Heat Transfer Mechanisms
article

Enhancing Heat Transfer in Turbulent Channel Flows: A Numerical Study on the Geometric and Orientational Effects of Delta, Trapezoidal, and Rectangular Winglet Vortex Generators

Atila Abir İğci
article en

Abstract

This paper presents a numerical study on the enhancement of heat transfer in a solar air heater (SAH) duct using winglet-type longitudinal vortex generators (WLVGs). Delta (DW), trapezoidal (TW1, TW2), and rectangular (RW) winglets are examined in pointing-up (PU) and pointing-down (PD) orientations, with the span-wise spacing ratio (S/H) varied to determine the optimal layout (S/H = 1.43, b/H = 0.50). Computational Fluid Dynamics (CFD) simulations using the GEKO turbulence model in ANSYS Fluent are performed for Reynolds numbers (Re) ranging from 5,000 to 22,500. Flow structures are analysed via Q-criterion isosurfaces, Nusselt number distributions, and streamwise vorticity contours. Results show that PU orientations generally outperform PD due to closer vortex–wall interaction. The RW configuration exhibits the highest Nusselt number, achieving a maximum Nusselt number of 114.37 at Re = 22,500, primarily attributed to the persistence of its generated vortices. However, it also results in the greatest frictional penalty, with a maximum friction factor of 0.1562 at Re = 5,000 and a corresponding normalized value of 𝑓/𝑓₀ = 5.21 at Re = 22,500. Consequently, the RW configuration yields the lowest thermal enhancement factor (TEF) at high Reynolds numbers, reaching a minimum value of 1.050 at Re = 22,500, despite its strong heat transfer rate. In contrast, the highest TEF is achieved with the PU TW1 configuration (TEF = 1.473 at Re = 5,000), which offers the most favourable balance between enhanced heat transfer and acceptable frictional losses. These results provide design-oriented implications for solar air heater (SAH) systems, identifying PU TW1 as the most energy-efficient configuration, whereas RW may be more suitable for applications where maximizing heat transfer rate is prioritised over minimising frictional losses.

Hittite Journal of Science & EngineeringVol. 13(1)
Yozgat Bozok Üniversitesi (TR)
Affordable and clean energy
Openalex Percentile: Top 30%
Heat Transfer Mechanisms
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.