Wavelet time-frequency analysis enhances noise-resilient quantification of corneal wave velocity and natural frequency in optical coherence elastography

In vivo characterization of corneal biomechanics using dynamic optical coherence elastography (OCE) requires accurate quantification of both the temporal and spectral features for transient, frequency-dependent corneal dynamics. However, conventional time-of-flight (TOF) and fast Fourier transform (FFT) methods are limited in resolving coupled time-frequency behaviors, especially under low signal-to-noise ratio (SNR) conditions. We introduce a wavelet-based method for simultaneous characterization of wave propagation and resonant oscillations in air-pulse OCE. A Morlet wavelet transform was employed, with parameters optimized for wave velocity ( F b = 0.2 and F c =1.0) and natural frequency ( F b =5, F c =7). The method was validated against TOF and FFT using agar phantoms, ex vivo porcine corneas (n = 26, IOP: 5–20 mmHg), and an in vivo rabbit model. The wavelet method showed excellent agreement with TOF and FFT under controlled conditions, with mean differences of 0.18 m/s for group velocity (2.3–5.2 m/s) and 0.5 Hz for natural frequency (176–437 Hz) in 1–2% agar phantoms. Critically, it outperformed TOF under challenging conditions, reducing the coefficient of variation by ∼50% (0.27 vs. 0.52) at low-SNR depths and preserving more valid data (86.3% vs. 50.0%) in stressed corneas at 20 mmHg. Its time-frequency localization further enabled the in vivo detection of transient vibrational changes, suggesting the potential to distinguish physiological modulations (e.g., heartbeat, respiration) that are not readily accessible with FFT. This work establishes a robust, noise-tolerant foundation for dynamic corneal elastography, potentially advancing dynamic OCE toward precise, clinically translatable assessment of corneal biomechanics.

Authors

Institutions

Publication Details

Journal
Biomedical Optics Express
Published
2026-03-31
DOI
https://doi.org/10.1364/boe.583117
Primary Topic
Ultrasound Imaging and Elastography
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Wavelet time-frequency analysis enhances noise-resilient quantification of corneal wave velocity and natural frequency in optical coherence elastography

Michael D. Twa, Gongpu Lan, Chengjin Song, Yanping Huang et al.
Biomedical Optics Express
Ultrasound Imaging and Elastography
article

Wavelet time-frequency analysis enhances noise-resilient quantification of corneal wave velocity and natural frequency in optical coherence elastography

Michael D. Twa, Gongpu Lan, Chengjin Song, Yanping Huang, Jingjiang Xu, Hongwei Yang, Lin An, yan deng, Jia Qin, Zhi Cao
article en

Abstract

In vivo characterization of corneal biomechanics using dynamic optical coherence elastography (OCE) requires accurate quantification of both the temporal and spectral features for transient, frequency-dependent corneal dynamics. However, conventional time-of-flight (TOF) and fast Fourier transform (FFT) methods are limited in resolving coupled time-frequency behaviors, especially under low signal-to-noise ratio (SNR) conditions. We introduce a wavelet-based method for simultaneous characterization of wave propagation and resonant oscillations in air-pulse OCE. A Morlet wavelet transform was employed, with parameters optimized for wave velocity ( F b = 0.2 and F c =1.0) and natural frequency ( F b =5, F c =7). The method was validated against TOF and FFT using agar phantoms, ex vivo porcine corneas (n = 26, IOP: 5–20 mmHg), and an in vivo rabbit model. The wavelet method showed excellent agreement with TOF and FFT under controlled conditions, with mean differences of 0.18 m/s for group velocity (2.3–5.2 m/s) and 0.5 Hz for natural frequency (176–437 Hz) in 1–2% agar phantoms. Critically, it outperformed TOF under challenging conditions, reducing the coefficient of variation by ∼50% (0.27 vs. 0.52) at low-SNR depths and preserving more valid data (86.3% vs. 50.0%) in stressed corneas at 20 mmHg. Its time-frequency localization further enabled the in vivo detection of transient vibrational changes, suggesting the potential to distinguish physiological modulations (e.g., heartbeat, respiration) that are not readily accessible with FFT. This work establishes a robust, noise-tolerant foundation for dynamic corneal elastography, potentially advancing dynamic OCE toward precise, clinically translatable assessment of corneal biomechanics.

Biomedical Optics ExpressVol. 17(5)
Nanchang University (CN), University of Houston (US), Hangzhou Dianzi University (CN)
National Natural Science Foundation of China, Guangdong Provincial Pearl River Talents Program, Basic and Applied Basic Research Foundation of Guangdong Province
Climate action
Openalex Percentile: Top 43%
Ultrasound Imaging and Elastography
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.