A High-Affinity but Low-Abundance Kanamycin Aptamer Reveals Hybridization-Limited Capture-SELEX

of 51 nM at pH 7.5 for kanamycin as measured by isothermal titration calorimetry, and its affinities to kanamycin A and B are similar. Using NMR spectroscopy methods, the KAN8-1 aptamer undergoes ligand-induced folding and likely has a better-defined structure compared to the KAN6-1 aptamer, which was highly enriched in the pH 6 selection. Using the KAN8-1 aptamer, a strand-displacement biosensor was developed, and it has a limit of detection of 0.9 μM with excellent selectivity. This sensor also has a similar performance in serum. The reason for the poor enrichment of KAN8-1 was attributed to its low hybridization efficiency and poor hybridization stability to the capture strand as demonstrated by a fluorescence titration assay and melting analysis, which indicated a limitation of the capture-SELEX method.

Authors

Institutions

Publication Details

Journal
Biochemistry
Published
2026-03-31
DOI
https://doi.org/10.1021/acs.biochem.5c00778
Primary Topic
RNA Research and Splicing
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A High-Affinity but Low-Abundance Kanamycin Aptamer Reveals Hybridization-Limited Capture-SELEX

Yuzhe Ding, Yunus A. Kaiyum, Philip E. Johnson, Juewen Liu et al.
Biochemistry
RNA Research and Splicing
article

A High-Affinity but Low-Abundance Kanamycin Aptamer Reveals Hybridization-Limited Capture-SELEX

Yuzhe Ding, Yunus A. Kaiyum, Philip E. Johnson, Juewen Liu, Qingyu Chen, Yicheng Heng, Emily Hoi Pui Chao
article en

Abstract

of 51 nM at pH 7.5 for kanamycin as measured by isothermal titration calorimetry, and its affinities to kanamycin A and B are similar. Using NMR spectroscopy methods, the KAN8-1 aptamer undergoes ligand-induced folding and likely has a better-defined structure compared to the KAN6-1 aptamer, which was highly enriched in the pH 6 selection. Using the KAN8-1 aptamer, a strand-displacement biosensor was developed, and it has a limit of detection of 0.9 μM with excellent selectivity. This sensor also has a similar performance in serum. The reason for the poor enrichment of KAN8-1 was attributed to its low hybridization efficiency and poor hybridization stability to the capture strand as demonstrated by a fluorescence titration assay and melting analysis, which indicated a limitation of the capture-SELEX method.

BiochemistryVol. 65(8)
University of Waterloo (CA), York University (CA), National Institute for Nanotechnology (CA)
Government of Ontario, Government of Canada, Canada Research Chairs, Natural Sciences and Engineering Research Council of Canada
Zero hunger
Openalex Percentile: Top 31%
RNA Research and Splicing
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.