Pre-procedural three-dimensional computed tomography vs. angiographic assessment for patent ductus arteriosus stenting: a comparative analysis

Background: Patent Ductus Arteriosus (PDA) stenting has become an established albeit complex intervention in ductal dependent congenital heart disease. Accurate pre-procedural planning is essential for successful stent placement, yet the optimal measurement methodology remains debated. This study compared the accuracy and clinical utility of routine pre-procedural three-dimensional (3D) computed tomography-derived measurements with traditional angiographic assessments for PDA stent sizing. Methods: = 12). PDA length measurements from CTA-derived 3D reconstruction and 2D angiography were compared against the actual stent length used. Statistical analysis included Pearson correlation, Bland-Altman agreement, and concordance correlation coefficients (CCC). Results: = 0.811) measurements correlated with stent length. Performance varied significantly by anatomical complexity. In Group 1 (straight), angiography demonstrated favorable accuracy with lower bias (-0.28 mm vs. 1.33 mm) and higher concordance (CCC: 0.807 vs. 0.681). In Group 2 (moderate tortuosity), angiographic performance showed greater underestimation and lower concordance (Bias -5.67 mm; CCC: 0.168), while 3D remained reliable (Bias -2.33 mm; CCC: 0.526). In Group 3 (severe tortuosity), 3D overestimated length (+3.1 mm) while angiography underestimated it (-2.88 mm), though angiographic consistency was higher (CCC: 0.704 vs. 0.559). Conclusion: Pre-procedural 3D measurements provide consistent reliability across varying degrees of anatomical complexity, offering an advantage in cases with moderate tortuosity where angiography may be vulnerable to foreshortening. Angiography remains highly accurate for straightforward anatomy. A complexity-stratified imaging approach is recommended to optimize stent selection.

Authors

Institutions

Publication Details

Journal
Frontiers in Cardiovascular Medicine
Published
2026-03-31
DOI
https://doi.org/10.3389/fcvm.2026.1767627
Primary Topic
Cardiovascular Conditions and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Pre-procedural three-dimensional computed tomography vs. angiographic assessment for patent ductus arteriosus stenting: a comparative analysis

Netanel Nagar, Avshalom Shaffer, Sharon Borik Chiger, David Hochstein et al.
Frontiers in Cardiovascular Medicine
Cardiovascular Conditions and Treatments
article

Pre-procedural three-dimensional computed tomography vs. angiographic assessment for patent ductus arteriosus stenting: a comparative analysis

Netanel Nagar, Avshalom Shaffer, Sharon Borik Chiger, David Hochstein, Shai Tejman-Yarden, Oliana Vajgovski, Yishay Salem, Yisrael Parmet, Liran Ceausu
article en

Abstract

Background: Patent Ductus Arteriosus (PDA) stenting has become an established albeit complex intervention in ductal dependent congenital heart disease. Accurate pre-procedural planning is essential for successful stent placement, yet the optimal measurement methodology remains debated. This study compared the accuracy and clinical utility of routine pre-procedural three-dimensional (3D) computed tomography-derived measurements with traditional angiographic assessments for PDA stent sizing. Methods: = 12). PDA length measurements from CTA-derived 3D reconstruction and 2D angiography were compared against the actual stent length used. Statistical analysis included Pearson correlation, Bland-Altman agreement, and concordance correlation coefficients (CCC). Results: = 0.811) measurements correlated with stent length. Performance varied significantly by anatomical complexity. In Group 1 (straight), angiography demonstrated favorable accuracy with lower bias (-0.28 mm vs. 1.33 mm) and higher concordance (CCC: 0.807 vs. 0.681). In Group 2 (moderate tortuosity), angiographic performance showed greater underestimation and lower concordance (Bias -5.67 mm; CCC: 0.168), while 3D remained reliable (Bias -2.33 mm; CCC: 0.526). In Group 3 (severe tortuosity), 3D overestimated length (+3.1 mm) while angiography underestimated it (-2.88 mm), though angiographic consistency was higher (CCC: 0.704 vs. 0.559). Conclusion: Pre-procedural 3D measurements provide consistent reliability across varying degrees of anatomical complexity, offering an advantage in cases with moderate tortuosity where angiography may be vulnerable to foreshortening. Angiography remains highly accurate for straightforward anatomy. A complexity-stratified imaging approach is recommended to optimize stent selection.

Frontiers in Cardiovascular MedicineVol. 13
Ben-Gurion University of the Negev (IL), Tel Aviv University (IL), Sheba Medical Center (IL), Edmond and Lily Safra Children's Hospital (IL)
Openalex Percentile: Top 39%
Cardiovascular Conditions and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.