Ultra‐Sensitive and Green LC–MS/MS Method for Trace‐Level Determination of Nitrosamine Drug Substance‐Related Impurities in the Anti‐Diuretic Drug Furosemide

ABSTRACT In recent years, the international pharmaceutical community has expressed heightened concern about the occurrence of nitrosamine impurities and nitrosamine drug substance‐related impurities (NDSRI), as these compounds are well recognized for their strong mutagenic activity in humans. Among the drugs of interest, furosemide, an anti‐diuretic drug, is one. Structural assessments of furosemide have revealed the potential for the formation of an NDSRI, specifically N‐nitroso‐furosemide (N‐FUR). According to the Carcinogenic Potency Categorization Approach, this impurity is classified as a Category 4 carcinogen, with an acceptable daily intake limit of 1500 ng/day. Given the elevated cancer risk associated with such impurities, the development of highly sensitive and selective quantitative analytical methodologies is imperative. In response to this need, a robust liquid chromatography–tandem mass spectrometry (LC–MS/MS) method was established for the trace‐level quantification of N‐FUR. Chromatographic separation was achieved using a Kinetex C 18 (100 mm × 3.0 mm, 2.6 µm), maintained at 45°C. The mobile phase consisted of water and methanol, in a 50:50 (%, v/v) ratio with 0.1% trifluoroacetic acid, delivered at a flow rate of 0.5 mL/min. Detection was performed using a multiple reaction monitoring approach in electro spray ionization, Negative mode, transitions monitored at m / z 358.0 → 284. The method was rigorously validated in accordance with international regulatory guidelines and demonstrated excellent performance characteristics, confirming its suitability for routine analysis. This validated LC–MS/MS method has been successfully transferred to the quality control unit, enabling routine monitoring of nitrosamine impurities in furosemide formulations.

Authors

Institutions

Publication Details

Journal
Separation Science Plus
Published
2026-03-31
DOI
https://doi.org/10.1002/sscp.70217
Primary Topic
Water Treatment and Disinfection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Ultra‐Sensitive and Green LC–MS/MS Method for Trace‐Level Determination of Nitrosamine Drug Substance‐Related Impurities in the Anti‐Diuretic Drug Furosemide

Santhosh Kumar Ettaboina, Naresh Kumar Katari, Satyasree Nannapaneni, Abhishek Sharma
Separation Science Plus
Water Treatment and Disinfection
article

Ultra‐Sensitive and Green LC–MS/MS Method for Trace‐Level Determination of Nitrosamine Drug Substance‐Related Impurities in the Anti‐Diuretic Drug Furosemide

Santhosh Kumar Ettaboina, Naresh Kumar Katari, Satyasree Nannapaneni, Abhishek Sharma
article en

Abstract

ABSTRACT In recent years, the international pharmaceutical community has expressed heightened concern about the occurrence of nitrosamine impurities and nitrosamine drug substance‐related impurities (NDSRI), as these compounds are well recognized for their strong mutagenic activity in humans. Among the drugs of interest, furosemide, an anti‐diuretic drug, is one. Structural assessments of furosemide have revealed the potential for the formation of an NDSRI, specifically N‐nitroso‐furosemide (N‐FUR). According to the Carcinogenic Potency Categorization Approach, this impurity is classified as a Category 4 carcinogen, with an acceptable daily intake limit of 1500 ng/day. Given the elevated cancer risk associated with such impurities, the development of highly sensitive and selective quantitative analytical methodologies is imperative. In response to this need, a robust liquid chromatography–tandem mass spectrometry (LC–MS/MS) method was established for the trace‐level quantification of N‐FUR. Chromatographic separation was achieved using a Kinetex C 18 (100 mm × 3.0 mm, 2.6 µm), maintained at 45°C. The mobile phase consisted of water and methanol, in a 50:50 (%, v/v) ratio with 0.1% trifluoroacetic acid, delivered at a flow rate of 0.5 mL/min. Detection was performed using a multiple reaction monitoring approach in electro spray ionization, Negative mode, transitions monitored at m / z 358.0 → 284. The method was rigorously validated in accordance with international regulatory guidelines and demonstrated excellent performance characteristics, confirming its suitability for routine analysis. This validated LC–MS/MS method has been successfully transferred to the quality control unit, enabling routine monitoring of nitrosamine impurities in furosemide formulations.

Separation Science PlusVol. 9(4)
Vignan's Foundation for Science, Technology & Research (IN), GITAM University (IN), University of KwaZulu-Natal (ZA)
Partnerships for the goals
Openalex Percentile: Top 28%
Water Treatment and Disinfection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.