Performance Analysis of Flow Control in a Ground Source Heat Pump Using a Heat Pump Simulator

This study investigates the performance of a ground source heat pump (GSHP) system using variable-flow control based on the temperature difference between the source-side inlet and outlet (ΔT), which is affected by the entering water temperature (EWT) and flow rate. A laboratory-scale test facility equipped with a thermostatic bath was utilized to analyze the coefficient of performance (COP) during both cooling and heating operations. A regression-based model for predicting COP was developed from the experimental data. The findings revealed that, under the same EWT conditions, increasing the flow rate gradually improved the COP, particularly in high-efficiency operating regions. Using the developed model, a 10-year long-term simulation was conducted to assess system-level performance. The optimal ΔT values for minimizing total energy consumption were found to be ΔT = 5℃ in cooling mode and ΔT = 4℃ in heating mode. Notably, increasing ΔT during cooling significantly reduced circulation pump power consumption, leading to enhanced overall system efficiency.

Authors

Publication Details

Journal
Korean Journal of Air-Conditioning and Refrigeration Engineering
Published
2026-03-31
DOI
https://doi.org/10.6110/kjacr.2026.38.4.214
Primary Topic
Geothermal Energy Systems and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Performance Analysis of Flow Control in a Ground Source Heat Pump Using a Heat Pump Simulator

Y. M. Park, Eui-Jong Kim
Korean Journal of Air-Conditioning and Refrigeration Engineering
Geothermal Energy Systems and Applications
article

Performance Analysis of Flow Control in a Ground Source Heat Pump Using a Heat Pump Simulator

Y. M. Park, Eui-Jong Kim
article en

Abstract

This study investigates the performance of a ground source heat pump (GSHP) system using variable-flow control based on the temperature difference between the source-side inlet and outlet (ΔT), which is affected by the entering water temperature (EWT) and flow rate. A laboratory-scale test facility equipped with a thermostatic bath was utilized to analyze the coefficient of performance (COP) during both cooling and heating operations. A regression-based model for predicting COP was developed from the experimental data. The findings revealed that, under the same EWT conditions, increasing the flow rate gradually improved the COP, particularly in high-efficiency operating regions. Using the developed model, a 10-year long-term simulation was conducted to assess system-level performance. The optimal ΔT values for minimizing total energy consumption were found to be ΔT = 5℃ in cooling mode and ΔT = 4℃ in heating mode. Notably, increasing ΔT during cooling significantly reduced circulation pump power consumption, leading to enhanced overall system efficiency.

Korean Journal of Air-Conditioning and Refrigeration EngineeringVol. 38(4)
Affordable and clean energy
Openalex Percentile: Top 13%
Geothermal Energy Systems and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.