DEVELOPMENT AND VALIDATION OF BISOPROLOL FUMARATE IN BULK AND PHARMACEUTICAL DOSAGE FORMS

UV Spectroscopy is a widely used analytical technique that involves the absorption of ultraviolet radiation by molecules, leading to electronic transitions. The aim of the presented work is to develop and validate a simple, rapid, accurate, precise and effective UV-spectroscopy method for the estimation of bisoprolol, an anti- hypertensive drug. Ethanol is used as the solvent for the preparation of stock solution as it shows good solubility when compared with the other solvents. The wavelength at maximum absorption (λ max) was found to be 273nm. The drug bisoprolol shows the linearity concentration range 20-180µg\ml with the correlation coefficient value of 0.9961and a regression equation y =0.004x+ 0.0311. Then a graph was plotted by taking the concentration x- axis and absorbance on y-axis which gives straight line percentage assay of bisoprolol in pharmaceutical formulation was found to be 99.58%. The LOD and LOQ was found to be 0.284 & 0.863 respectively.Precision studies show acceptable results with intraday precision and interday precision as %RSD <2 method validation was carried out in accordance with international council of harmonization guidelines.

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-04-01
DOI
https://doi.org/10.5281/zenodo.19329505
Primary Topic
Analytical Methods in Pharmaceuticals
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

DEVELOPMENT AND VALIDATION OF BISOPROLOL FUMARATE IN BULK AND PHARMACEUTICAL DOSAGE FORMS

Zenodo (CERN European Organization for Nuclear Research)
Analytical Methods in Pharmaceuticals
article

DEVELOPMENT AND VALIDATION OF BISOPROLOL FUMARATE IN BULK AND PHARMACEUTICAL DOSAGE FORMS

article en

Abstract

UV Spectroscopy is a widely used analytical technique that involves the absorption of ultraviolet radiation by molecules, leading to electronic transitions. The aim of the presented work is to develop and validate a simple, rapid, accurate, precise and effective UV-spectroscopy method for the estimation of bisoprolol, an anti- hypertensive drug. Ethanol is used as the solvent for the preparation of stock solution as it shows good solubility when compared with the other solvents. The wavelength at maximum absorption (λ max) was found to be 273nm. The drug bisoprolol shows the linearity concentration range 20-180µg\ml with the correlation coefficient value of 0.9961and a regression equation y =0.004x+ 0.0311. Then a graph was plotted by taking the concentration x- axis and absorbance on y-axis which gives straight line percentage assay of bisoprolol in pharmaceutical formulation was found to be 99.58%. The LOD and LOQ was found to be 0.284 & 0.863 respectively.Precision studies show acceptable results with intraday precision and interday precision as %RSD <2 method validation was carried out in accordance with international council of harmonization guidelines.

Zenodo (CERN European Organization for Nuclear Research)
Partnerships for the goals
Openalex Percentile: Top 20%
Analytical Methods in Pharmaceuticals
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.