Performance Analysis of PVT-Heat Pump Integrated System under Low-Temperature Thermal Storage Conditions According to Operation Strategies

Air source heat pumps (ASHP) experience performance degradation at low outdoor temperatures, resulting in a significant decrease in their COP. To address this limitation, this study proposes a hybrid operation that integrates a heat pump with a photovoltaic-thermal (PVT) system. A PVT-heated storage tank can offer a more stable heat source; however, under low-temperature thermal storage conditions, the operation of an auxiliary boiler may be necessary, leading to performance variations based on the chosen control strategy. Using TRNSYS 18, we compared two operation modes: Case 1, where a boiler reheats the tank before the water-to-water heat pump operates, and Case 2, where a dual-source heat pump automatically switches to air-source mode. Results showed that Case 1 achieved a higher seasonal COP (3.86) than Case 2 (3.65), indicating that boiler intervention effectively prevents performance degradation. In terms of energy consumption and CO₂ emissions, Case 1 recorded lower CO₂ emissions (1,572 ㎏CO₂) than Case 2 (1,607 ㎏CO₂). Moreover, Case 1’s PVT system generated 5,488.9 ㎾h during the heating season, exceeding the heat pump’s consumption (3,102.8 ㎾h) and enabling energy self-sufficiency. The annual CO₂ reduction reached 4,247 ㎏CO₂, offsetting system emissions and providing additional mitigation. These findings demonstrate that under low-temperature storage conditions, Case 1 represents the optimal strategy for both heating performance and environmental benefits when integrated with PVT.

Authors

Publication Details

Journal
Korean Journal of Air-Conditioning and Refrigeration Engineering
Published
2026-03-31
DOI
https://doi.org/10.6110/kjacr.2026.38.4.193
Primary Topic
Refrigeration and Air Conditioning Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Performance Analysis of PVT-Heat Pump Integrated System under Low-Temperature Thermal Storage Conditions According to Operation Strategies

Jaeman Song, Hiki Hong, Yujin Lee, Junyong Lee
Korean Journal of Air-Conditioning and Refrigeration Engineering
Refrigeration and Air Conditioning Technologies
article

Performance Analysis of PVT-Heat Pump Integrated System under Low-Temperature Thermal Storage Conditions According to Operation Strategies

Jaeman Song, Hiki Hong, Yujin Lee, Junyong Lee
article en

Abstract

Air source heat pumps (ASHP) experience performance degradation at low outdoor temperatures, resulting in a significant decrease in their COP. To address this limitation, this study proposes a hybrid operation that integrates a heat pump with a photovoltaic-thermal (PVT) system. A PVT-heated storage tank can offer a more stable heat source; however, under low-temperature thermal storage conditions, the operation of an auxiliary boiler may be necessary, leading to performance variations based on the chosen control strategy. Using TRNSYS 18, we compared two operation modes: Case 1, where a boiler reheats the tank before the water-to-water heat pump operates, and Case 2, where a dual-source heat pump automatically switches to air-source mode. Results showed that Case 1 achieved a higher seasonal COP (3.86) than Case 2 (3.65), indicating that boiler intervention effectively prevents performance degradation. In terms of energy consumption and CO₂ emissions, Case 1 recorded lower CO₂ emissions (1,572 ㎏CO₂) than Case 2 (1,607 ㎏CO₂). Moreover, Case 1’s PVT system generated 5,488.9 ㎾h during the heating season, exceeding the heat pump’s consumption (3,102.8 ㎾h) and enabling energy self-sufficiency. The annual CO₂ reduction reached 4,247 ㎏CO₂, offsetting system emissions and providing additional mitigation. These findings demonstrate that under low-temperature storage conditions, Case 1 represents the optimal strategy for both heating performance and environmental benefits when integrated with PVT.

Korean Journal of Air-Conditioning and Refrigeration EngineeringVol. 38(4)
Affordable and clean energy
Openalex Percentile: Top 10%
Refrigeration and Air Conditioning Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.