Comparing transthoracic echocardiography, 2D and 4D flow cardiovascular magnetic resonance for quantitative valve assessment after percutaneous pulmonary valve implantation

Abstract Aim To compare transthoracic echocardiography (TTE), 2D and 4D flow cardiovascular magnetic resonance (CMR) for the evaluation of valve function and flow measurements after percutaneous pulmonary valve implantation (PPVI). Methods In this multicentre exploratory observational study, 29 patients who underwent PPVI were planned for TTE and CMR with 2D and 4D flow measurements after PPVI. Peak velocity was measured with all techniques. Net and regurgitating flow measurements were measured with CMR distal to the transcatheter pulmonary valve (TPV). Results Median peak velocity of the transcatheter pulmonary valve (TPV) with TTE was 2.5 (2.0-3.1) m/s, with 2D flow CMR 2.3 (2.0-3.2) m/s, and with 4D flow 2.3 (2.0-3.0) m/s. There was a good correlation for the peak velocity of the TPV between TTE and 2D flow CMR (r=0.68, p<0.001) and a moderate correlation for peak velocity between TTE and 4D flow CMR (r=0.56, p=0.003), and between 2D flow and 4D flow CMR (r=0.56, p=0.006). For peak velocity measurements, no proportional bias was observed between the three imaging techniques. For the CMR flow measurements, a strong correlation was observed between 2D and 4D flow CMR, for both net flow (r=0.87, p<0.001) and regurgitation fraction (r=0.96, p<0.001) of the TPV. Net flow through the left pulmonary artery correlated strongly between 2D and 4D flow CMR (r=0.85, p<0.001), and there was a good correlation for the right pulmonary artery (r=0.65, p<0.01). For net flow measurements of the TPV, we found an underestimation of flow measurements at higher flow rates with 4D flow CMR, compared to 2D flow CMR. Conclusion TTE, 2D and 4D flow CMR are all feasible and reliable imaging techniques after PPVI, concordant in predominantly mild-to-moderate stenosis. These findings strengthen the use of 2D and 4D flow CMR as a tool for post-PPVI assessment, despite stent induced artifacts, although reliability in more advanced valve dysfunction remains uncertain.

Authors

Institutions

Publication Details

Journal
European Heart Journal - Imaging Methods and Practice
Published
2026-03-27
DOI
https://doi.org/10.1093/ehjimp/qyag054
Primary Topic
Cardiac Valve Diseases and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparing transthoracic echocardiography, 2D and 4D flow cardiovascular magnetic resonance for quantitative valve assessment after percutaneous pulmonary valve implantation

Anthonie L. Duijnhouwer, João Gomes Carvalho, M. Faure, Jeroen M. Wilschut et al.
European Heart Journal - Imaging Methods and Practice
Cardiac Valve Diseases and Treatments
article

Comparing transthoracic echocardiography, 2D and 4D flow cardiovascular magnetic resonance for quantitative valve assessment after percutaneous pulmonary valve implantation

Anthonie L. Duijnhouwer, João Gomes Carvalho, M. Faure, Jeroen M. Wilschut, R P J Budde, A H Hirsch, Tim ten Cate, Annemien E van den Bosch, Jolien W Roos-Hesselink
article en

Abstract

Abstract Aim To compare transthoracic echocardiography (TTE), 2D and 4D flow cardiovascular magnetic resonance (CMR) for the evaluation of valve function and flow measurements after percutaneous pulmonary valve implantation (PPVI). Methods In this multicentre exploratory observational study, 29 patients who underwent PPVI were planned for TTE and CMR with 2D and 4D flow measurements after PPVI. Peak velocity was measured with all techniques. Net and regurgitating flow measurements were measured with CMR distal to the transcatheter pulmonary valve (TPV). Results Median peak velocity of the transcatheter pulmonary valve (TPV) with TTE was 2.5 (2.0-3.1) m/s, with 2D flow CMR 2.3 (2.0-3.2) m/s, and with 4D flow 2.3 (2.0-3.0) m/s. There was a good correlation for the peak velocity of the TPV between TTE and 2D flow CMR (r=0.68, p<0.001) and a moderate correlation for peak velocity between TTE and 4D flow CMR (r=0.56, p=0.003), and between 2D flow and 4D flow CMR (r=0.56, p=0.006). For peak velocity measurements, no proportional bias was observed between the three imaging techniques. For the CMR flow measurements, a strong correlation was observed between 2D and 4D flow CMR, for both net flow (r=0.87, p<0.001) and regurgitation fraction (r=0.96, p<0.001) of the TPV. Net flow through the left pulmonary artery correlated strongly between 2D and 4D flow CMR (r=0.85, p<0.001), and there was a good correlation for the right pulmonary artery (r=0.65, p<0.01). For net flow measurements of the TPV, we found an underestimation of flow measurements at higher flow rates with 4D flow CMR, compared to 2D flow CMR. Conclusion TTE, 2D and 4D flow CMR are all feasible and reliable imaging techniques after PPVI, concordant in predominantly mild-to-moderate stenosis. These findings strengthen the use of 2D and 4D flow CMR as a tool for post-PPVI assessment, despite stent induced artifacts, although reliability in more advanced valve dysfunction remains uncertain.

European Heart Journal - Imaging Methods and Practice
Radboud University Nijmegen (NL), Erasmus MC (NL), University Medical Center (US), Radboud University Medical Center (NL), Province of Antwerp (BE), Hospital de Santo António (PT), Erasmus MC Cancer Institute (NL), Centro Hospitalar do Porto (PT), Erasmus University Rotterdam (NL)
Openalex Percentile: Top 3%
Cardiac Valve Diseases and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.