Development of Internal Quality Control Material for ABO and Rhesus D Blood Grouping in Vietnam: A Preliminary Experimental Study

Abstract: BACKGROUND: ABO and Rhesus D (RhD) blood group systems are essential for transfusion safety. In Vietnam, the absence of domestically produced internal quality control (IQC) materials has resulted in reliance on costly and inconsistently supplied imported products or nonstandardized in-house controls. AIMS AND OBJECTIVES: To preliminarily assess the homogeneity, transport stability, and storage stability of the IQC material for ABO and RhD blood grouping. METHODOLOGY: An experimental study was conducted to produce eight IQC lots representing ABO and RhD blood group systems. A total of 272 samples were prepared. Homogeneity and stability were evaluated in accordance with ISO/IEC 17043:2023 and ISO 13528:2022 guidelines using column agglutination methods. The results were assessed using the predefined acceptance criteria and descriptive concordance analysis. RESULTS: Homogeneity testing demonstrated uniform serologic performance, with >95% of reactions exhibiting strong agglutination (≥3+) and 0% false positive results. All IQC lots (100%) met the predefined acceptance criteria and were classified as PASS. Transport stability at 2°C–8°C for 7 days showed complete retention of agglutination strength and specificity without hemolysis. Storage stability remained consistent for 6 weeks, with minor noninterpretive 4+ to 3+ shifts in <10% of samples. All stability assessments remained within acceptance limits. CONCLUSIONS: The IQC material for ABO and RhD blood grouping demonstrated satisfactory homogeneity and stability, meeting the ISO acceptance criteria. This supports the feasibility of domestic IQC production to improve quality assurance in transfusion laboratories in Vietnam. The findings should be interpreted in light of the limited sample size and study setting.

Authors

Institutions

Publication Details

Journal
Journal of Applied Hematology
Published
2026-01-01
DOI
https://doi.org/10.4103/joah.joah_154_25
Primary Topic
Blood donation and transfusion practices
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of Internal Quality Control Material for ABO and Rhesus D Blood Grouping in Vietnam: A Preliminary Experimental Study

Oanh Hoang Le, Hue Van Thi Tran, Nguyễn Nhật Trần, P. Nguyen et al.
Journal of Applied Hematology
Blood donation and transfusion practices
article

Development of Internal Quality Control Material for ABO and Rhesus D Blood Grouping in Vietnam: A Preliminary Experimental Study

Oanh Hoang Le, Hue Van Thi Tran, Nguyễn Nhật Trần, P. Nguyen, Bao Quoc Nguyen, Phuc Thi Diem Huynh, Dao Hong Trinh, Cuong Khanh Nguyen
article en

Abstract

Abstract: BACKGROUND: ABO and Rhesus D (RhD) blood group systems are essential for transfusion safety. In Vietnam, the absence of domestically produced internal quality control (IQC) materials has resulted in reliance on costly and inconsistently supplied imported products or nonstandardized in-house controls. AIMS AND OBJECTIVES: To preliminarily assess the homogeneity, transport stability, and storage stability of the IQC material for ABO and RhD blood grouping. METHODOLOGY: An experimental study was conducted to produce eight IQC lots representing ABO and RhD blood group systems. A total of 272 samples were prepared. Homogeneity and stability were evaluated in accordance with ISO/IEC 17043:2023 and ISO 13528:2022 guidelines using column agglutination methods. The results were assessed using the predefined acceptance criteria and descriptive concordance analysis. RESULTS: Homogeneity testing demonstrated uniform serologic performance, with >95% of reactions exhibiting strong agglutination (≥3+) and 0% false positive results. All IQC lots (100%) met the predefined acceptance criteria and were classified as PASS. Transport stability at 2°C–8°C for 7 days showed complete retention of agglutination strength and specificity without hemolysis. Storage stability remained consistent for 6 weeks, with minor noninterpretive 4+ to 3+ shifts in <10% of samples. All stability assessments remained within acceptance limits. CONCLUSIONS: The IQC material for ABO and RhD blood grouping demonstrated satisfactory homogeneity and stability, meeting the ISO acceptance criteria. This supports the feasibility of domestic IQC production to improve quality assurance in transfusion laboratories in Vietnam. The findings should be interpreted in light of the limited sample size and study setting.

Journal of Applied HematologyVol. 17(1)
University Medical Center HCMC (VN), HCMC Hospital of Dermato Venereology (VN), Hong Bang International University (VN), Pham Ngoc Thach Hospital (VN)
Openalex Percentile: Top 3%
Blood donation and transfusion practices
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.