Experimental evaluation of a R290 vapour compression refrigeration system hybridised with a thermoelectric subcooler

• First experimental study of a thermoelectric subcooler in propane cooling systems. • Systematic COP improvements of 3.6–––6.2% under all tested operating conditions. • Maximum COP achieved at low thermoelectric subcooler voltages (1.0–––1.5 V) • Flexible TESC operation boosts cooling capacity up to 16.2% in pull-down processes. The HVAC and refrigeration sector accounts for a significant share of global electricity consumption and greenhouse gas emissions, driving the adoption of low global warming potential refrigerants and more energy-efficient technologies. Among these refrigerants, propane has emerged as a promising alternative, and thermoelectric subcooling has been identified as an attractive performance-enhancing solution for low-capacity applications, motivating the design and construction of an experimental propane refrigeration test bench. This facility incorporates an internal heat exchanger to ensure safe and reliable operation, along with a novel thermoelectric subcooler (TESC). The experimental tests have been performed at two different ambient (25 and 35 °C) and evaporating (−15 and −10 °C) temperatures, and varying the voltage supplied to the TEMs. Two system configurations were evaluated: the baseline cycle with only the internal heat exchanger (IHX), which serves as the reference, and the combined TESC + IHX configuration. Performance comparisons between the two configurations were conducted for all the tested operating temperatures. The results show that the TESC + IHX configuration outperforms the IHX configuration under all tested conditions, with improvements in coefficient of performance of up to 6.2% and increases in cooling capacity of up to 9.7% at the optimal operating point. In addition, the TESC allows an almost linear regulation of the cooling capacity by adjusting the supplied voltage. This feature provides not only improved system performance but also greater operational flexibility and controllability, enabling the system to adapt to changes in ambient conditions and transient peak demands without the need for oversizing.

Authors

Institutions

Publication Details

Journal
Energy Conversion and Management
Published
2026-03-28
DOI
https://doi.org/10.1016/j.enconman.2026.121393
Primary Topic
Refrigeration and Air Conditioning Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental evaluation of a R290 vapour compression refrigeration system hybridised with a thermoelectric subcooler

Antonio Manuel Reyes Rodríguez, Patricia Aranguren, Iñaki Alzuguren, Álvaro Casi et al.
Energy Conversion and Management
Refrigeration and Air Conditioning Technologies
article

Experimental evaluation of a R290 vapour compression refrigeration system hybridised with a thermoelectric subcooler

Antonio Manuel Reyes Rodríguez, Patricia Aranguren, Iñaki Alzuguren, Álvaro Casi, Daniel Sánchez
article en

Abstract

• First experimental study of a thermoelectric subcooler in propane cooling systems. • Systematic COP improvements of 3.6–––6.2% under all tested operating conditions. • Maximum COP achieved at low thermoelectric subcooler voltages (1.0–––1.5 V) • Flexible TESC operation boosts cooling capacity up to 16.2% in pull-down processes. The HVAC and refrigeration sector accounts for a significant share of global electricity consumption and greenhouse gas emissions, driving the adoption of low global warming potential refrigerants and more energy-efficient technologies. Among these refrigerants, propane has emerged as a promising alternative, and thermoelectric subcooling has been identified as an attractive performance-enhancing solution for low-capacity applications, motivating the design and construction of an experimental propane refrigeration test bench. This facility incorporates an internal heat exchanger to ensure safe and reliable operation, along with a novel thermoelectric subcooler (TESC). The experimental tests have been performed at two different ambient (25 and 35 °C) and evaporating (−15 and −10 °C) temperatures, and varying the voltage supplied to the TEMs. Two system configurations were evaluated: the baseline cycle with only the internal heat exchanger (IHX), which serves as the reference, and the combined TESC + IHX configuration. Performance comparisons between the two configurations were conducted for all the tested operating temperatures. The results show that the TESC + IHX configuration outperforms the IHX configuration under all tested conditions, with improvements in coefficient of performance of up to 6.2% and increases in cooling capacity of up to 9.7% at the optimal operating point. In addition, the TESC allows an almost linear regulation of the cooling capacity by adjusting the supplied voltage. This feature provides not only improved system performance but also greater operational flexibility and controllability, enabling the system to adapt to changes in ambient conditions and transient peak demands without the need for oversizing.

Energy Conversion and ManagementVol. 356
Universitat Jaume I (ES), Universidad Pública de Navarra (UPNA) (ES)
Affordable and clean energy
Openalex Percentile: Top 5%
Refrigeration and Air Conditioning Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.