Assessment of PHRED Score Characteristics in Illumina MiSeq Amplicon Sequencing

PHRED scores are confidence values associated with each basecall generated by sequencers. The score is defined as a monotonic function of the probability that the basecall is incorrect. The calibration of PHRED scores has previously been examined by evaluating errors made in reading known sequences. We investigated the calibration of the Illumina MiSeq instrument PHRED model using data from a large dataset. We also derive calibration methods for the PHRED scores in datasets similar to those produced by the Global Hepatitis Outbreak and Surveillance Technology (GHOST). The GHOST protocol uses a short amplicon, resulting in many positions having two base calls, one coming from each of the paired reads. A maximum likelihood model of redundant base calls that match each other was used to estimate corrected probabilities of the PHRED scores. The PHRED scores showed only small absolute deviations from their target values. These differences are statistically significant deviations (<mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"><mml:mrow><mml:mi>p</mml:mi><mml:mo> </mml:mo><mml:mo><</mml:mo><mml:mo> </mml:mo><mml:mn>0.0001</mml:mn></mml:mrow></mml:math>) from being calibrated. The accuracy of the scores varied significantly between the MiSeq instrument runs. Recalibration produced quality scores that improved Brier scores for the dataset by an average relative improvement of <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"><mml:mrow><mml:mn>2.83</mml:mn><mml:mi>%</mml:mi></mml:mrow></mml:math>. Methods developed to create calibration curves for PHRED scores will be useful in improving error-correction pipelines based on redundant deep sequencing of amplicon data. However, quality scores are relatively uninformative of substitution errors. The quality scores assigned are determined more by the global error rate of the sequencing run in the current machine cycle than by the characteristics of the specific base call.

Authors

Institutions

Publication Details

Journal
Journal of Computational Biology
Published
2026-03-28
DOI
https://doi.org/10.1177/15578666261436820
Primary Topic
Hepatitis C virus research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Assessment of PHRED Score Characteristics in Illumina MiSeq Amplicon Sequencing

Seth Sims, Alexander Zelikovsky, YURY KHUDYAKOV
Journal of Computational Biology
Hepatitis C virus research
article

Assessment of PHRED Score Characteristics in Illumina MiSeq Amplicon Sequencing

Seth Sims, Alexander Zelikovsky, YURY KHUDYAKOV
article en

Abstract

PHRED scores are confidence values associated with each basecall generated by sequencers. The score is defined as a monotonic function of the probability that the basecall is incorrect. The calibration of PHRED scores has previously been examined by evaluating errors made in reading known sequences. We investigated the calibration of the Illumina MiSeq instrument PHRED model using data from a large dataset. We also derive calibration methods for the PHRED scores in datasets similar to those produced by the Global Hepatitis Outbreak and Surveillance Technology (GHOST). The GHOST protocol uses a short amplicon, resulting in many positions having two base calls, one coming from each of the paired reads. A maximum likelihood model of redundant base calls that match each other was used to estimate corrected probabilities of the PHRED scores. The PHRED scores showed only small absolute deviations from their target values. These differences are statistically significant deviations (<mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"><mml:mrow><mml:mi>p</mml:mi><mml:mo> </mml:mo><mml:mo><</mml:mo><mml:mo> </mml:mo><mml:mn>0.0001</mml:mn></mml:mrow></mml:math>) from being calibrated. The accuracy of the scores varied significantly between the MiSeq instrument runs. Recalibration produced quality scores that improved Brier scores for the dataset by an average relative improvement of <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"><mml:mrow><mml:mn>2.83</mml:mn><mml:mi>%</mml:mi></mml:mrow></mml:math>. Methods developed to create calibration curves for PHRED scores will be useful in improving error-correction pipelines based on redundant deep sequencing of amplicon data. However, quality scores are relatively uninformative of substitution errors. The quality scores assigned are determined more by the global error rate of the sequencing run in the current machine cycle than by the characteristics of the specific base call.

Journal of Computational Biology
Centers for Disease Control and Prevention (US), Sechenov University (RU), Georgia State University (US), The Centers (US)
Quality Education, Good health and well-being
Openalex Percentile: Top 4%
Hepatitis C virus research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.