Bond of ribbed and threaded steel reinforcement bars post-installed in concrete considering bonded length and adhesive type

Post-installing steel bars-or anchors-using chemical agents is nowadays instrumental in repairing and strengthening existing concrete structures. In this experimental research project, beside three cast-in-place specimens provided with ordinary ribbed bars (reference specimens), eighteen specimens were designed and cast to investigate bond performance of chemically-bonded steel bars placed inside concrete blocks, subjected to a pull-out load. Specimens and reinforcement consisted in concrete cubes (side a = 250 mm) and small bars (diameter db = 10 mm). Concrete strength on cubes was 28 MPa. The parameters under investigation were: bonded length (Lb = 5/10/15 db), drilled-hole diameter (= 1.2/1.6/1.8 db), bar properties (ribbed or threaded surface in the post-installed bars) and adhesive type (Sikadur 31CF and Kimapoxy 165). Bond-slip response, bond strength and bar slip at the peak stress, failure modes, as well as bond ductility and stiffness were thoroughly investigated. As expected, in most of the chemically-bonded and cast-in-place specimens bond failure was by steel yielding within a pull out framework (no cover splitting). For the intermediate and largest hole diameters (= 1.6 and 1.8 db), the load-bearing capacity of post-installed bars was slightly larger than that of ordinary bars. In the specimens with post-installed bars, the bearing capacities with Sikadur 31CF and Kimapoxy 165 turned out to be very close for any bonded length. The bond capacity of post-installed threaded bars was from 12 to 21% less than that of post-installed ribbed bars. Compared to ordinary ribbed bars, bond ductility in post-installed bars was higher (from + 18 to + 25% for Lb = 5 db) or even much higher (from 5 to 10 times for Lb = 10 and 15 db). Finally, to evaluate bond resistance of post-installed bars, a new equation is proposed to take care of all major parameters, based on the test results of this study.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2026-03-28
DOI
https://doi.org/10.1038/s41598-026-42964-4
Primary Topic
Structural Behavior of Reinforced Concrete
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Bond of ribbed and threaded steel reinforcement bars post-installed in concrete considering bonded length and adhesive type

Mohammed K. Alkharisi, Ahmed Hamoda, Sabry Fayed, Mohamed Ghalla et al.
Scientific Reports
Structural Behavior of Reinforced Concrete
article

Bond of ribbed and threaded steel reinforcement bars post-installed in concrete considering bonded length and adhesive type

Mohammed K. Alkharisi, Ahmed Hamoda, Sabry Fayed, Mohamed Ghalla, EL-Said A. Bayoumi, Md. Habibur Rahman Sobuz, Sani Aliyu Abubakar
article en

Abstract

Post-installing steel bars-or anchors-using chemical agents is nowadays instrumental in repairing and strengthening existing concrete structures. In this experimental research project, beside three cast-in-place specimens provided with ordinary ribbed bars (reference specimens), eighteen specimens were designed and cast to investigate bond performance of chemically-bonded steel bars placed inside concrete blocks, subjected to a pull-out load. Specimens and reinforcement consisted in concrete cubes (side a = 250 mm) and small bars (diameter db = 10 mm). Concrete strength on cubes was 28 MPa. The parameters under investigation were: bonded length (Lb = 5/10/15 db), drilled-hole diameter (= 1.2/1.6/1.8 db), bar properties (ribbed or threaded surface in the post-installed bars) and adhesive type (Sikadur 31CF and Kimapoxy 165). Bond-slip response, bond strength and bar slip at the peak stress, failure modes, as well as bond ductility and stiffness were thoroughly investigated. As expected, in most of the chemically-bonded and cast-in-place specimens bond failure was by steel yielding within a pull out framework (no cover splitting). For the intermediate and largest hole diameters (= 1.6 and 1.8 db), the load-bearing capacity of post-installed bars was slightly larger than that of ordinary bars. In the specimens with post-installed bars, the bearing capacities with Sikadur 31CF and Kimapoxy 165 turned out to be very close for any bonded length. The bond capacity of post-installed threaded bars was from 12 to 21% less than that of post-installed ribbed bars. Compared to ordinary ribbed bars, bond ductility in post-installed bars was higher (from + 18 to + 25% for Lb = 5 db) or even much higher (from 5 to 10 times for Lb = 10 and 15 db). Finally, to evaluate bond resistance of post-installed bars, a new equation is proposed to take care of all major parameters, based on the test results of this study.

Scientific Reports
Kafrelsheikh University (EG), Khulna University of Engineering and Technology (BD), Qassim University (SA), Kampala International University (UG), Higher Institute of Engineering (EG)
Sustainable cities and communities
Openalex Percentile: Top 4%
Structural Behavior of Reinforced Concrete
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.