Experimental study and load control of concentric electromagnetic damper under intensive impact load

Background: Conventional electromagnetic dampers impose a bias torque on artillery systems, which adversely affects system stability and performance. Objective: This study aims to propose a novel concentric electromagnetic damper (C-EMD). Based on the principle of electromagnetic induction, it achieves efficient braking to effectively eliminate the aforementioned bias torque effect. Methods: First, a nonlinear dynamic model of the C-EMD was established through theoretical analysis, finite element simulations, and impact experiments. This model was used to analyze the mechanism by which magnetic flux density affects damping performance and the parameter influence patterns. Subsequently, parameter sensitivity analysis was conducted using Optimal Latin Hypercube Design (OLHD) and polynomial regression methods. Finally, a surrogate model based on elliptic basis neural networks was developed, and multi-objective optimization was performed by integrating multi-island genetic algorithms with nonlinear programming by quadratic lagrangian. Results: Modeling analysis revealed that the resultant resistance curve exhibits a saddle-shaped profile with a concave center and elevated ends. Parameter sensitivity analysis results showed that liner thickness and air gap thickness have the most significant impact on performance (contributions >26%), while the influence of outer tube thickness is minimal (only 0.83%). Post-optimization results demonstrated: a reduction in resultant resistance curve flatness to 1.42, an increase in fill ratio to 89.86%, a 4.63% decrease in maximum displacement, and near-complete elimination of the saddle-shaped characteristics. Conclusions: This research provides an innovative solution for enhancing electromagnetic damper performance, with significant practical implications.

Authors

Institutions

Publication Details

Journal
International Journal of Applied Electromagnetics and Mechanics
Published
2026-03-28
DOI
https://doi.org/10.1177/13835416261433383
Primary Topic
Vibration Control and Rheological Fluids
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental study and load control of concentric electromagnetic damper under intensive impact load

N. Liu, Longchun Tao, Dong Yu, Mengxi Ma et al.
International Journal of Applied Electromagnetics and Mechanics
Vibration Control and Rheological Fluids
article

Experimental study and load control of concentric electromagnetic damper under intensive impact load

N. Liu, Longchun Tao, Dong Yu, Mengxi Ma, Sheng Ruan
article en

Abstract

Background: Conventional electromagnetic dampers impose a bias torque on artillery systems, which adversely affects system stability and performance. Objective: This study aims to propose a novel concentric electromagnetic damper (C-EMD). Based on the principle of electromagnetic induction, it achieves efficient braking to effectively eliminate the aforementioned bias torque effect. Methods: First, a nonlinear dynamic model of the C-EMD was established through theoretical analysis, finite element simulations, and impact experiments. This model was used to analyze the mechanism by which magnetic flux density affects damping performance and the parameter influence patterns. Subsequently, parameter sensitivity analysis was conducted using Optimal Latin Hypercube Design (OLHD) and polynomial regression methods. Finally, a surrogate model based on elliptic basis neural networks was developed, and multi-objective optimization was performed by integrating multi-island genetic algorithms with nonlinear programming by quadratic lagrangian. Results: Modeling analysis revealed that the resultant resistance curve exhibits a saddle-shaped profile with a concave center and elevated ends. Parameter sensitivity analysis results showed that liner thickness and air gap thickness have the most significant impact on performance (contributions >26%), while the influence of outer tube thickness is minimal (only 0.83%). Post-optimization results demonstrated: a reduction in resultant resistance curve flatness to 1.42, an increase in fill ratio to 89.86%, a 4.63% decrease in maximum displacement, and near-complete elimination of the saddle-shaped characteristics. Conclusions: This research provides an innovative solution for enhancing electromagnetic damper performance, with significant practical implications.

International Journal of Applied Electromagnetics and Mechanics
Nanjing University of Science and Technology (CN), Xiangtan Electric Manufacturing Group (China) (CN)
Openalex Percentile: Top 4%
Vibration Control and Rheological Fluids
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Experimental study and load control of concentric electromagnetic damper under intensive impact load — N. Liu, Longchun Tao, et al. · International Journal of Applied Electromagnetics and Mechanics (2026) | TGRS Research Map | TGRS