Miniaturized Chromate-Free Chloride Assay in Fish Sauce Based on Linear Height Calibration of AgCl Precipitate in Inverted Microtubes

• Chromate-free, miniaturized argentometric method for chloride analysis • Direct height-based calibration enabled by geometry-controlled microtubes • Instrument-light assay using ruler readout and low-speed centrifugation • Microliter-scale reagents reduce silver waste and energy consumption • Validated green screening of chloride in high-salt food matrices A miniaturized, chromate-free methodology for chloride determination in high-salt food matrices is presented in accordance with the principles of Green Analytical Chemistry. Classical argentometric precipitation is adapted to a microvolume, instrument-light assay by confining silver chloride formation within inverted microcentrifuge tubes and directly measuring the height of the compact precipitate layer using a simple ruler. Because the cylindrical tube region has a constant cross-sectional area, precipitate height is directly proportional to chloride concentration, enabling straightforward linear calibration without optical detection, signal transduction, or complex data processing. Controlled tube inversion and low-speed centrifugation ensure that precipitation occurs exclusively within this cylindrical zone, producing a sharp, reproducible solid–liquid interface. Under optimized conditions (150 µL sample volume and 180 µL of AgNO₃ in nitric acid; centrifugation at 600 rpm for 3 min followed by 5 min settling), the method provides a linear working range of 50–500 mM chloride (r² = 0.9988), a detection limit of 14 mM, and relative standard deviations of 3–4% at 200–300 mM. Validation of 12 commercial Thai fish sauce samples showed no statistically significant differences compared to AOAC potentiometric titration at the 95% confidence level, with recoveries of 100–103% and %RSD values of 1–4.2%. The primary advantage of this method is its strictly linear height–concentration relationship, enabled by geometry-controlled confinement of the precipitate. Unlike other miniaturized or paper-based assays, it eliminates the need for image analysis or device fabrication. From a green chemistry perspective, the assay eliminates the use of potassium chromate indicators and disposable paper-based devices, operates at the microliter scale using reusable plastic microtubes, and requires only low-speed centrifugation. Analytical Greenness (AGREE), Analytical Eco-scale, Green Analytical Procedure Index (GAPI), and White Analytical Chemistry (WAC) evaluations (AGREE score: 0.76; Eco-scale: 83; WAC score: 88.9) classify the method as an excellent example of green analysis. The proposed approach offers a robust and sustainable screening tool for chloride determination in high-salt foods.

Authors

Institutions

Publication Details

Journal
Green Analytical Chemistry
Published
2026-03-01
DOI
https://doi.org/10.1016/j.greeac.2026.100343
Primary Topic
Biosensors and Analytical Detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Miniaturized Chromate-Free Chloride Assay in Fish Sauce Based on Linear Height Calibration of AgCl Precipitate in Inverted Microtubes

Wiboon Praditweangkum, Rattikan Chantiwas, Prapin Wilairat, Papawarin Putthasa et al.
Green Analytical Chemistry
Biosensors and Analytical Detection
article

Miniaturized Chromate-Free Chloride Assay in Fish Sauce Based on Linear Height Calibration of AgCl Precipitate in Inverted Microtubes

Wiboon Praditweangkum, Rattikan Chantiwas, Prapin Wilairat, Papawarin Putthasa, Benjamapohn Cheotchinda, Saowapak Teerasong
article en

Abstract

• Chromate-free, miniaturized argentometric method for chloride analysis • Direct height-based calibration enabled by geometry-controlled microtubes • Instrument-light assay using ruler readout and low-speed centrifugation • Microliter-scale reagents reduce silver waste and energy consumption • Validated green screening of chloride in high-salt food matrices A miniaturized, chromate-free methodology for chloride determination in high-salt food matrices is presented in accordance with the principles of Green Analytical Chemistry. Classical argentometric precipitation is adapted to a microvolume, instrument-light assay by confining silver chloride formation within inverted microcentrifuge tubes and directly measuring the height of the compact precipitate layer using a simple ruler. Because the cylindrical tube region has a constant cross-sectional area, precipitate height is directly proportional to chloride concentration, enabling straightforward linear calibration without optical detection, signal transduction, or complex data processing. Controlled tube inversion and low-speed centrifugation ensure that precipitation occurs exclusively within this cylindrical zone, producing a sharp, reproducible solid–liquid interface. Under optimized conditions (150 µL sample volume and 180 µL of AgNO₃ in nitric acid; centrifugation at 600 rpm for 3 min followed by 5 min settling), the method provides a linear working range of 50–500 mM chloride (r² = 0.9988), a detection limit of 14 mM, and relative standard deviations of 3–4% at 200–300 mM. Validation of 12 commercial Thai fish sauce samples showed no statistically significant differences compared to AOAC potentiometric titration at the 95% confidence level, with recoveries of 100–103% and %RSD values of 1–4.2%. The primary advantage of this method is its strictly linear height–concentration relationship, enabled by geometry-controlled confinement of the precipitate. Unlike other miniaturized or paper-based assays, it eliminates the need for image analysis or device fabrication. From a green chemistry perspective, the assay eliminates the use of potassium chromate indicators and disposable paper-based devices, operates at the microliter scale using reusable plastic microtubes, and requires only low-speed centrifugation. Analytical Greenness (AGREE), Analytical Eco-scale, Green Analytical Procedure Index (GAPI), and White Analytical Chemistry (WAC) evaluations (AGREE score: 0.76; Eco-scale: 83; WAC score: 88.9) classify the method as an excellent example of green analysis. The proposed approach offers a robust and sustainable screening tool for chloride determination in high-salt foods.

Green Analytical Chemistry
Mahidol University (TH), King Mongkut's Institute of Technology Ladkrabang (TH)
Affordable and clean energy
Openalex Percentile: Top 5%
Biosensors and Analytical Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.