Metallic biomaterials in soft tissue fixation: Applications in wound closure, tendon repair, and vascular ligation

Metallic surgical closure devices are widely used in wound closure, tendon repair, and vascular ligation due to their superior mechanical strength, stability, and durability compared to polymeric alternatives. Non-absorbable metals such as stainless steel, titanium, silver, and Nitinol provide reliable long-term fixation. In contrast, bioabsorbable metals, including magnesium, zinc, and iron, have emerged as promising alternatives that degrade after fulfilling their function, thereby reducing the need for secondary removal procedures. Despite their advantages, both permanent and bioabsorbable metallic devices require further optimization in biocompatibility, mechanical performance, and surface modifications to minimize foreign body reactions, reduce device-related complications, and improve integration with surrounding tissues. For bioabsorbable metals, key challenges include controlling degradation rates, avoiding excessive hydrogen release in magnesium-based devices, and enhancing structural integrity during the healing process. This review provides a comprehensive comparison of metallic surgical closure devices, with particular focus on sutures, staples, clips, screws, tags, and plugs, examining their applications, advantages, and limitations, as well as material selection and technological innovations that could improve clinical performance. • Metals outperform polymers in strength and durability for surgical closure. • Sutures offer precision, while staples and clips allow faster, lower-risk closure. • Stainless steel, Ti, and Nitinol dominate non-absorbable surgical fixation devices. • Mg, Zn, and Fe show promise for absorbable implants but need optimized degradation. • Future research should improve safety, stability, and imaging of metal closure devices.

Authors

Institutions

Publication Details

Journal
Smart Materials in Manufacturing
Published
2026-01-01
DOI
https://doi.org/10.1016/j.smmf.2026.100135
Primary Topic
Reconstructive Surgery and Microvascular Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Metallic biomaterials in soft tissue fixation: Applications in wound closure, tendon repair, and vascular ligation

Anahita Rohani Shirvan, Alireza Nouri, Samin Yousefi, Delaram Balu
Smart Materials in Manufacturing
Reconstructive Surgery and Microvascular Techniques
article

Metallic biomaterials in soft tissue fixation: Applications in wound closure, tendon repair, and vascular ligation

Anahita Rohani Shirvan, Alireza Nouri, Samin Yousefi, Delaram Balu
article en

Abstract

Metallic surgical closure devices are widely used in wound closure, tendon repair, and vascular ligation due to their superior mechanical strength, stability, and durability compared to polymeric alternatives. Non-absorbable metals such as stainless steel, titanium, silver, and Nitinol provide reliable long-term fixation. In contrast, bioabsorbable metals, including magnesium, zinc, and iron, have emerged as promising alternatives that degrade after fulfilling their function, thereby reducing the need for secondary removal procedures. Despite their advantages, both permanent and bioabsorbable metallic devices require further optimization in biocompatibility, mechanical performance, and surface modifications to minimize foreign body reactions, reduce device-related complications, and improve integration with surrounding tissues. For bioabsorbable metals, key challenges include controlling degradation rates, avoiding excessive hydrogen release in magnesium-based devices, and enhancing structural integrity during the healing process. This review provides a comprehensive comparison of metallic surgical closure devices, with particular focus on sutures, staples, clips, screws, tags, and plugs, examining their applications, advantages, and limitations, as well as material selection and technological innovations that could improve clinical performance. • Metals outperform polymers in strength and durability for surgical closure. • Sutures offer precision, while staples and clips allow faster, lower-risk closure. • Stainless steel, Ti, and Nitinol dominate non-absorbable surgical fixation devices. • Mg, Zn, and Fe show promise for absorbable implants but need optimized degradation. • Future research should improve safety, stability, and imaging of metal closure devices.

Smart Materials in ManufacturingVol. 4
University of British Columbia (CA), Deakin University (AU), Islamic Azad University, Science and Research Branch (IR)
Openalex Percentile: Top 3%
Reconstructive Surgery and Microvascular Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.